Return to search

Análise dinâmica aplicada ao controle passivo de vibrações em estrutura do tipo pórtico incorporando minimolas superelásticas de nitinol. / Dynamical Analysis Applied to Control Passive of Vibrations in an Structural Device Incorporating Superelastic NiTi Mini Coil Springs.

Submitted by Kilvya Braga (kilvyabraga@hotmail.com) on 2018-04-26T14:31:48Z
No. of bitstreams: 1
YURI JOSÉ OLIVEIRA MORAES - DISSERTAÇÃO (PPGEM) 2017.pdf: 4856362 bytes, checksum: 1833eec6cc553ca6e2578b9a019e362b (MD5) / Made available in DSpace on 2018-04-26T14:31:48Z (GMT). No. of bitstreams: 1
YURI JOSÉ OLIVEIRA MORAES - DISSERTAÇÃO (PPGEM) 2017.pdf: 4856362 bytes, checksum: 1833eec6cc553ca6e2578b9a019e362b (MD5)
Previous issue date: 2017-02-15 / Capes / As vibrações de natureza mecânica são fenômenos importantes do mundo físico. Geralmente, tais oscilações podem se tornar indesejáveis de tal forma a vir a causar danos temporários ou o próprio colapso de sistemas mecânicos e estruturais. Com o intuito de conter estes efeitos, tem-se pesquisado técnicas que venham a controlar e/ou minimizar as implicações deste fenômeno, que vão desde métodos de natureza passiva, até o uso de controladores com materiais inteligentes. Este estudo tem como objetivo, analisar um sistema de controle passivo de vibrações instalado em uma estrutura que simula um edifício de dois andares e dois graus de liberdade (2GDL). Este sistema é baseado na incorporação de duas configurações de minimolas superelásticas (LMF–NiTi–SE), para dissipação de energia e acréscimo de amortecimento estrutural. Uma análise modal e estrutural foi realizada para avaliar o comportamento do sistema, a partir de métodos analíticos, numéricos e experimentais. Em caráter experimental, as amplitudes de resposta da estrutura foram analisadas para solicitações do sistema em vibração livre, forçada e transiente (sísmica), em todas as configurações. Em comparação com a estrutura com molas de aço convencional, as análises das FRF’s em vibração forçada mostraram uma redução na transmissibilidade de até 51% para o primeiro modo de vibrar e 73% para o segundo modo na configuração de quatro minimolas individuais LMF, e estes valores aumentaram para 55% e 85% respectivamente, na configuração de oito minimolas duplas LMF. Quanto aos fatores de amortecimento, houve um aumento considerável da ordem de 119% no primeiro modo e de 109% no segundo modo de vibração, na configuração das minimolas individuais LMF. Na caracterização dinâmica determinaram-se a energia dissipada nas frequências naturais e amplitude de deformação, validando a análise e o método de controle passivo empregado. / Mechanical vibrations are important phenomena of the physical world. Generally, such oscillations may become undesirable in such a way as to cause temporary damage or the actual collapse of mechanical and structural systems. In order to contain these effects, we have researched techniques that will control and/or minimize the implications of this phenomenon, ranging from passive methods to the use of controllers with smart materials. This study aims to analyze a passive vibration control system installed in a structure that simulates a two floors building and two degrees of freedom (2DOF). This system is based on the incorporation of two superelastic mini coil springs configurations (SMA–NiTi–SE) for energy dissipation and increase of structural damping. A modal and structural analysis was performed to evaluate the behavior of the system, from analytical, numerical and experimental methods. On an experimental basis, the response amplitudes of the structure were analyzed for system requirements in free, forced and transient (seismic) vibration in all configurations. Compared with the conventional steel spring structure, the forced vibration FRF’s analysis showed a reduction in transmissibility of up to 51% for the first vibrating mode and 73% for the second mode in the four mini coil springs individual configuration SMA. And these values increased to 55% and 85% respectively, in the eight mini coil springs double configuration SMA. As for the damping factors, there was a considerable increase in the order of 119% in the first mode and 109% in the second mode of vibration, in the mini coil springs individual configuration SMA. In the dynamic characterization the energy dissipated in the natural frequencies and amplitude of deformation was determined, validating the analysis and the passive control method employed.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/502
Date26 April 2018
CreatorsMORAES, Yuri José Oliveira.
ContributorsSILVA, Antonio Almeida., ARAÚJO, Carlos José de., RODRIGUES, Marcelo Cavalcanti.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA MECÂNICA, UFCG, Brasil, Centro de Ciências e Tecnologia - CCT
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0088 seconds