Return to search

Continuous flash extraction of alcohols from fermentation broth

A new method of in situ extraction of alcohols from fermentation broth was investigated. The extraction method exploited the latent advantages of the non-equilibrium phase interaction of the fluid system in the flash tank to effectively recover the alcohol. Carbon dioxide gas ranging from 4.2L/min to 12.6L/min was used to continuously strip 2 and 12% (v/v) ethanol solution in a fermentor with a recycle. Ethanol and water in the stripped gas was recovered by compressing and then flashing into a flash tank that was maintained at 5 to 70bar and 5 to 55oC where two immiscible phases comprising CO2-rich phase (top layer) and H2O-rich phase (bottom layer) were formed. The H2O-rich bottom layer was collected as the Bottoms. The CO2-rich phase was continuously throttled producing a condensate (Tops) as a result of the Joule-Thompson cooling effect. The total ethanol recovered from the extraction scheme was 46.0 to 80% for the fermentor containing 2% (v/v) ethanol and 57 to 89% for the fermentor containing 12% (v/v) ethanol. The concentration of ethanol in the Bottoms ranged from 8.0 to 14.9 %(v/v) for the extraction from the 2 %(v/v) ethanol solution and 40.0 to 53.8 %(v/v) for the 12% (v/v) fermentor ethanol extraction. The Bottoms concentration showed a fourfold increase compared to the feed. The ethanol concentration of the Tops were much higher with the highest at approx. 90% (v/v) ethanol, however the yields were extremely low. Compression work required ranged from 6.4 to 20.1 MJ/kg ethanol recovered from the gas stream in the case of 12% (v/v) ethanol in fermentor. The energy requirement for the 2% (v/v) extraction was 84MJ/kg recovered ethanol. The measured Joule-Thompson cooling effect for the extraction scheme was in the range of 10 to 20% the work of compressing the gas. The lowest measured throttle valve temperature was -47oC at the flash tank conditions of 70bar and 25oC. Optimization of the extraction scheme showed that increasing the temperature of the flash tank reduced the amount of ethanol recovered. Increasing the pressure of the flash tank increased the total ethanol recovered but beyond 45bar it appeared to reduce the yield. The 12.6L/min carbon dioxide flow rate favored the high pressure(70bar) extraction whiles 4.2L/min appeared to favor the low pressure(40bar) extraction. The studies showed that the extraction method could potentially be used to recover ethanol and other fermentation products. / Master of Science

Identiferoai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/31418
Date30 March 2009
CreatorsTeye, Frederick David
ContributorsBiological Systems Engineering, Agblevor, Foster Aryi, Zhang, Chenming Mike, Achenie, Luke E. K.
PublisherVirginia Tech
Source SetsVirginia Tech Theses and Dissertation
Detected LanguageEnglish
TypeThesis
Formatapplication/pdf
RightsIn Copyright, http://rightsstatements.org/vocab/InC/1.0/
RelationThesis_ETD8.pdf

Page generated in 0.003 seconds