Return to search

Avaliação da contaminação microbiológica e de procedimentos de desinfecção de esponjas utilizadas em serviços de alimentação / Evaluation of microbiological contamination and disinfection procedures of sponges used in food services

Esponjas de cozinha podem promover contaminação cruzada ao transferirem microrganismos de superfícies variadas para os alimentos. Os objetivos deste estudo foram avaliar a contaminação microbiológica e a eficácia de dois procedimentos de desinfecção de esponjas utilizadas em serviços de alimentação, bem como avaliar a transferência microbiana a partir de esponjas para o aço inoxidável e polietileno. Na primeira parte deste estudo, 80 esponjas naturalmente contaminadas foram coletadas em serviços de alimentação e então transferidas para o laboratório, onde foram divididas em três partes iguais. Uma das partes foi submetida à contagem de microrganismos heterotróficos (MH), coliformes a 45 oC (CF), Staphylococcus coagulase positiva (SA) e à pesquisa de Salmonella sp. (SAM). As outras duas partes foram submetidas, separadamente, à fervura em água durante cinco minutos e à desinfecção por hipoclorito de sódio 200ppm, por 10 minutos, adicionada de enxágue com água potável. Na segunda parte do estudo, 24 esponjas naturalmente contaminadas foram friccionadas sobre superfícies de aço inoxidável AISI 316 e polietileno, separadamente, a fim de investigar o número de microrganismos transferidos e sua sobrevivência. Os resultados demonstraram contaminações médias por MH de aproximadamente 9,1 LogUFC/esponja, e 76,25% delas apresentaram contagens médias de CF de aproximadamente 8,4 Log UFC/esponja. Apenas 2,5% das amostras apresentaram SA e SAM. Ambos os procedimentos de desinfecção foram capazes de reduzir significativamente as contagens bacterianas, porém a fervura demonstrou reduções maiores (6,7 Log UFC/esponja) que a desinfecção por hipoclorito de sódio a 200ppm (2,7 Log UFC/esponja ). A média de transferência de microrganismos variou entre 3,3 e 5,5 LogUFC/cm2, para aço inoxidável, entre 3,5 e 5,6 LogUFC/cm2, para o polietileno, sendo que os microrganismos transferidos foram perdendo sua viabilidade sobre ambos materiais. Nas primeiras quatro horas de exposição em temperatura ambiente a redução do número de microrganismos foi mais acentuada, e em 24 horas restaram cerca de 1 a 2 logUFC/cm2 de microrganismos viáveis. / Kitchen sponges can promote cross-contamination by transferring microorganisms from various surfaces to food. The objectives of this study were to evaluate the microbiological contamination and effectiveness of two procedures for disinfection of sponges used in food services, and to assess the microbial transfer from sponges to stainless steel and polyethylene. In the first part of this study, 80 sponges were collected in food services and then transferred to the laboratory where they were divided into three equal parts. One part was subjected to quantification of heterotrophic microorganisms (HM), fecal coliforms (CF), Staphylococcus coagulase-positive (SA) and Salmonella sp. (SAM). The other two parts were separately subjected to boilling in water for five minutes, and disinfection by sodium hypochlorite 200ppm for 10 minutes, added by rinse with water. In the second part of the study, 24 naturally contaminated sponges were rubbed on surfaces of AISI 316 stainless steel and polyethylene, separately, to investigate the number of transferred microorganisms and their survival. The results showed contamination averages by HM of approximately 9.1 log CFU/sponge, and 76.25% had average scores of CF of about 8.4 log CFU/sponge. Both disinfection procedures were able to significantly reduce bacterial counts, but the boiling showed greater reductions (6.7 log CFU/sponge) than the disinfection by sodium hypochlorite at 200ppm (2.7 log CFU/sponge) The average transfer of microorganisms varied between 3.3 and 5.5 log CFU/cm2 for stainless steel, and 3.5 to 5.6 log CFU/cm2, for polyethylene, and the transferred microorganisms were losing their viability on both materials. In the first four hours of exposure at room temperature the reduction of the number of microorganisms was more pronounced, and in 24 hours there were about 1 to 2 log CFU/cm2 remaining viable microorganisms.

Identiferoai:union.ndltd.org:IBICT/oai:lume.ufrgs.br:10183/24854
Date January 2010
CreatorsRossi, Eliandra Mirlei
ContributorsTondo, Eduardo Cesar
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFRGS, instname:Universidade Federal do Rio Grande do Sul, instacron:UFRGS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0032 seconds