Influência dos ciclos de cocção da porcelana na força de destorque de parafusos de estruturas implanto-retidas / Influence of porcelain fire cycles on detorque resistance of screws from implant-retained structures

Orientador: Guilherme Elias Pessanha Henriques / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:50:10Z (GMT). No. of bitstreams: 1
Torres_JoseWalterMurta_D.pdf: 1581851 bytes, checksum: 0bbcce2409164d19a4e51f955b38d595 (MD5)
Previous issue date: 2013 / Resumo: Este trabalho avaliou a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr) após fundição e simulação dos ciclos de cocção da porcelana. Dois implantes hexágono externo - com 3,75 mm de diâmetro - foram posicionados, com o auxílio de um paralelômetro fresador (1000N; Bio-art), na posição de segundo pré-molar e segundo molar num troquel de resina acrílica, de maneira a ficarem parcialmente submersos na resina expondo apenas suas plataformas de adaptação. Foram confeccionados 10 troqueis de resina acrílica (n=10). A partir de cada troquel foi obtida, pelo método de fundição da cera perdida, uma infraestrutura implanto-retida utilizando-se dois cilindros calcináveis tipo UCLA. A amostra foi submetida à força de torque de seus parafusos de fixação a 20 Ncm, registrada por meio de um torquímetro digital de precisão (Torque Meter TQ-8800; Lutron), e reapertados após 10 minutos. A força de destorque foi registrada após 24 horas do torque inicial. A resistência ao destorque foi analisada após fundição da estrutura protética e simulação dos três ciclos de cocção da porcelana (opaco dentina e glaze). Foram obtidas médias de destorque para cada estrutura nas distintas etapas de avaliação no estudo. Os dados foram analisados estatisticamente pelos testes ANOVA one-way e Bonferroni, com nível de significância de 5% (p<0,05). Os valores das médias da força de destorque dos parafusos por fase foram 13,95 ± 1,12 Ncm para pós-fundição, 15,20 ± 1,18 Ncm para ciclo Opaco, 15,85 ± 1,13 Ncm para ciclo Dentina e 16,80 ± 1,03 Ncm para o glaze. A força de destorque dos parafusos após a fundição foi significativamente menor do que a obtida para os grupos que simularam o ciclo de cocção da porcelana (p<0,05). Entre as fases de simulação dos ciclos cerâmicos, observou-se maior valor da força de destorque para o glaze (p<0,05), não sendo observadas diferenças estatisticamente significantes entre as fases opaco e dentina (p>0,05). Foi possível verificar que os ciclos de cocção da porcelana influenciam a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr). Observou-se que os valores de destorque aumentaram gradativamente com cada ciclo de cocção da porcelana / Abstract: This study evaluated the resistance to detorque of screws from implant-retained metal structures cast in nickel-chromium (Ni-Cr) after metal casting and simulation of porcelain firing cycle. Two external hex implants - with 3.75 mm diameters - were placed with the help of a parallelometer cutter (1000N; Bio-art), in the position of second premolar and second molar in acrylic resin die, so as to be partially submerged in the resin exposing only their platforms for adaptation. Thereupon, 10 dies were made with acrylic resin (n= 10). An implant-retained infrastructure from each die was obtained by the method of lost wax casting, using two UCLA cylinders. The sample of acrylic structures were subjected to 20 Ncm of torque to its fixing screws registered by means of a precision digital torque wrench (Torque Meter TQ-8800; Lutron) and retightened after 10 minutes. The measure of detorque was recorded 24 hours after the initial torque. The detorque resistance was analyzed after denture casting, followed by the simulation of porcelain firing cycles (opaque, dentin and glaze). Detorque averages were obtained for each structure at different stages of evaluation in this study. Data was statistically analyzed by one-way ANOVA and Bonferroni tests, at 5% significance level (p>0.05). We performed necessary statistical tests. The mean detorque force of the screws per phase were 13.95 ± 1.12 Ncm for post-casting; 15.20 ± 1.18 Ncm for cycle opaque; 15.85 ± 1.13 Ncm for cycle dentin; and 16.80 ± 1.03 Ncm for glazing. The screw's post-casting detorque resistance was significantly lower than that observed for the groups simulating porcelain firing cycles (p<0.05). Among groups simulating ceramic's cycles, the highest detorque resistance was observed for glaze group (p<0.05), with no significant statistical differences among opaque and dentin groups (p>0.05). It was possible that the porcelain firing cycle influenced detorque resistance of screws in implant-retained metal structures cast in nickel-chromium (Ni-Cr). It was observed that detorque values gradually increased after each porcelain firing cycle / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289175
Date21 August 2018
CreatorsTorres, José Walter Murta, 1958-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Henriques, Guilherme Elias Pessanha, 1968-, Fragoso, Wagner Sotero, Neto, Arcelino Farias, Mesquita, Marcelo Ferraz, Nóbilo, Mauro Antonio de Arruda
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format53 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.002 seconds