• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 1
  • Tagged with
  • 43
  • 43
  • 16
  • 16
  • 15
  • 15
  • 13
  • 10
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia de tipos de cimentos na resistencia a tração de coroas metalicas submetidas a ciclagem termica

Santos, Julie Guzela dos 28 June 2001 (has links)
Orientador : Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T16:57:01Z (GMT). No. of bitstreams: 1 Santos_JulieGuzelados_M.pdf: 2530316 bytes, checksum: f66788a804e87b02ab1d904ca3eec91f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar a resistência à remoção por tração e o tipo de falha da união de coroas totais metálicas fixadas com cimento de Fosfato de Zinco, cimento de Ionômero de Vidro Modificado por Resina e cimento de Resina, sobre preparos padronizados com diferentes tipos de término cervical, após ciclagem térmica. Foram utilizados 72 dentes incisivos inferiores bovinos os quais tiveram suas raízes incluídas em resina epóxica. As porções coronárias foram preparadas em tomo mecânico com paredes axiais com expulsividade de 10° e término cervical em ombros biselado, reto e chanfrado. A obtenção dos padrões de cera foi realizada diretamente sobre os preparos com auxílio de uma matriz para padronização de espessura. As coroas metálicas foram fundidas com liga de Ni-Cr (Verabond 2- Alba Dental Inc.) utilizando maçarico gás/oxigênio. Após a limpeza e jateamento com óxido de alumínio (50micro m), as coroas metálicas foram dividas em 3 grupos de 24 corpos-de-prova correspondentes aos tipos de término do preparo, sendo 08 amostras para cada tipo de agente de fixação. Os três cimentos usados foram manipulados de acordo com os fabricantes em ambiente de temperatura e umidade controlada e as coroas foram fixadas com auxílio de prensa pneumática, com carga estática de 9 kg por 10 minutos. Após 24 horas de armazenagem em estufa a 37°C com umidade relativa de 100 %, as amostras foram submetidas à ciclagem térmica com 500 ciclos entre 5 e 55°C e posteriormente o ensaio de tração foi realizado na máquina de ensaio universal Instron com velocidade de 1 mm/min. Os resultados submetidos a análise estatística ANOV A e ao teste de Tukey (p> 0,05) mostraram que os cimentos foram estatisticamente diferentes,independente do término cervical do preparo. O cimento de resina obteve a maior média de valores de resistência à remoção por tração (24,97 kgf), seguida pelo fosfato (13,35 kgf) e pelo cimento de ionômero modificado por resina (10,16 kgf). Os términos cervicais não apresentaram diferença estatística significante, independente do fator cimento. As falhas de união foram predominantemente do tipo mista para os cimentos de fosfato e de resina, e mista e adesiva para o cimento de ionômero de vidro modificado por resina / Abstract: The purpose of this study was to evaluate the strength tensile of complete cast crowns luted with 3 dental cements. Seventy-two bovin incisors were embedded in epoxic resin. The coronal portions of the teeth were prepared to receive complete crowns using a 4103 diamond bur under refrigeration with 10° of tapering and three types of finishing line 45-degree chamfered, 20-degree bevel shoulder and right shoulder. The wax patterns were made on the prepared teeth with matrix for standardized the thickness. The complete crowns were made with Ni-Cr alloy (Verabond 2 - Alba Dental Inc.). After the crowns were c1eaned and blasted with aluminum oxide (50 micro m) they were separated in three groups of twenty-four specimens each one. Afterwards the crowns were luted to the teeth preparations with zinc phosphate cement (SSWHITE), resin-modified glass ionômero cement (Vitremer-3M) and resin cement with adhesive (Resin Cement and Scothbond-3M). After 24 hours the specimens were submitted to 500 cyc1es between 5°C and 55°C, and to the tension tests on Instron machine with a speed of 1 mm/min. The results were analyzed by ANOV A and Tukey's test (p < 0.05) and the means showed that the great value was in the group of resin cement (24.97 kgf) followed by zinc phosphate (13.35 kgf) and resin modified glass ionomer (10 .16 kgf) alI statistically differents. The three types of finishing line were statistically similar / Mestrado / Mestre em Materiais Dentários
2

Avaliação da resistencia e do padrão de fratura de coroas ceramicas fixadas sobre diferentes reconstruções

Pizi, Eliane Cristina Gava 14 March 2003 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T15:08:16Z (GMT). No. of bitstreams: 1 Pizi_ElianeCristinaGava_D.pdf: 4414695 bytes, checksum: 1ca7079c5e69cf6ebbf33e2db3e6dc87 (MD5) Previous issue date: 2003 / Resumo: A proposta deste estudo foi avaliar in vitro a resistência e o padrão de fratura de coroas cerâmicas Cergogold / Dulceragold (Degussa), após fixação adesiva sobre diferentes reconstruções: (G1) preparo coronário em dentina, (G2) resina composta (Z250), (G3) pino de fibra de vidro (FibreKor), (G4) pino de fibra de vidro reembasado em resina composta (FibreKor + Z250), (G5) núcleo em cerâmica prensada (Cergogold), e (G6) núcleo metálico fundido (liga cobre-alumínio). Sessenta incisivos inferiores bovinos tratados endodonticamente, com dimensões médias semelhantes, foram incluídos em cilindros de resina de poliestireno com reprodução do ligamento periodontal. Após a reconstrução dos pinos e da porção coronária mantendo um preparo para coroa total com 60 de expulsividade, foram moldados e as restaurações cerâmicas foram confeccionadas. As coroas foram fixadas e armazenadas em ambiente com 100 % de umidade a 37 °C por 24 horas e, então, submetidas ao carregamento de compressão sob angulação de 135° com velocidade de 0,5 mm/min até a fratura. Os valores de resistência à fratura foram submetidos à análise de variância e posteriormente foi aplicado o teste de Tukey. Foram observados também o padrão de fratura da coroa cerâmica e do sistema de retenção intra-radicular conforme os seguintes critérios. Padrão de fratura da coroa cerâmica: (I) pequena fratura ou trinca na coroa cerâmica, (lI) fratura extensa na coroa cerâmica, (III) fratura extensa da coroa cerâmica com envolvimento da estrutura dental; padrão de fratura da retenção intra-radicular: (a) fratura do núcleo de preenchimento, (b) fratura do núcleo e/ou dente com envolvimento periodontal. Os valores médios do teste de resistência à fratura em Kgf foram: 42,7 ± 10,3 Kgf (G1)a; 42,0 ± 10,9 Kgf (G6)ab; 31,7 ± 6,1 Kgf (G3)bc; 31,5 ± 4,7 Kgf (G4)bc; 27,0 ± 6,4 Kgf (G5)c; 22,2 ± 8,6 Kgf (G2)c. O grupo com preparo em dentina apresentou os maiores resultados de resistência à fratura, semelhante apenas ao grupo do núcleo metálico fundido. Os dois grupos com pinos de fibra de vidro foram semelhantes entre si, e só diferiram do grupo com preparo em dentina. Os grupos que apresentaram resultados inferiores foram o grupo somente preenchido com resina composta e o grupo com núcleo em cerãmica. Quanto ao padrão de fratura, os grupos de fibra de vidro tiveram comportamento semelhante ao grupo com remanescente dentinário na porção coronária, e o único grupo que apresentou fratura radicular com envolvimento periodontal foi o grupo reconstruído com núcleo metálico fundido / Abstract: The aim of this study was to evaluate the fracture strength and failure pattern of Cergogold / Dulceragold (Degussa) ceramic crowns, after adhesive cementation over different core build-ups: (G1) dentin preparation; (G2) composite resin (Z250), (G3) glass fiber post (FibreKor), (G4) composite-rebased glass fiber post (FibreKor + Z250), (G5) pressed ceramic core (Cergogold), and (G6) cast core post (tin-copper alloy). Sixty endodontically treated bovine incisors, with similar dimensions, were included in polystyrene resin cylinders with periodontal ligament reproduction. After crown reconstruction and preparation with and expulsive angulation of 6°, teeth were molded and ceramic restorations were prepared as per manufacturer's instructions. Ceramic crowns were luted and stored at 37 °C and 100 % relative humidity for 24 hours before testing. Specimens were submitted to a compression load at a 135 o angulation and a crosshead speed of 0.5 mm/min until failure. Fracture strength values were statistically analyzed by ANOVA and Tukey testo Mean fracture strength values were: 42,7 ± 10,3 Kgf (G1)a; 42,0 ± 10,9 Kgf (G6)ab; 31,7 ± 6,1 Kgf (G3)bc; 31,5 ± 4,7 Kgf (G4)bc; 27,0 ± 6,4 Kgf (G5)c; 22,2 ± 8,6 Kgf (G2)c. The failure pattern of the ceramic crown and the intra-radicular retention system was determined according to the following types: (I) small fracture or crack in the ceramic crown, (lI) big fracture of the ceramic crown, (III) big fracture of the ceramic crown and core material, (a) fracture of the core material, (b) fracture of the core andj or dental structure with periodontal involvement. The group with dentin preparation presented the highest fracture strength means, similar to the group restored with cast core posts. The groups restored with glass fibers presented similar results, but were statistically different from the group with dentin preparation. The groups which presented the lowest means were the group which was restored only with composite resin and the group restored with a ceramic core posto Regarding the failure pattem, the groups restored with glass fiber posts presented results similar to the group with dentin preparation. The group restored with cast core post presented a high number of failures with periodontal involvement / Doutorado / Dentística / Doutor em Clínica Odontológica
3

Estabilidade mecanica de retentores do tipo coroa total

Silva, Wilkens Aurelio Buarque e, 1967- 04 July 1995 (has links)
Orientador: Frederico Andrade e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T11:45:48Z (GMT). No. of bitstreams: 1 Silva_WilkensAurelioBuarquee_M.pdf: 2887452 bytes, checksum: 0b71ed157e45bf5685d0b21d1ab7f5f1 (MD5) Previous issue date: 1995 / Resumo: O objetivo deste trabalho, foi avaliar a forma de resitência, em preparos para coroas totais, com preservação dos ângulos axo-proximais, variando-se a convergência entre as paredes axiais, com e sem canaletas proximais e, sem a interposição de um meio cimentante. Foram confeccionados oitenta (80) preparos do tipo coroa total com ângulos axo-proximais em dentes naturais. Quarenta (40) com cana retas e quarenta (40) sem canaletas. Os preparos com ombro maior que 90° foram executados com as seguintes convergências: 6°, 8°, 12° e 16° em cada uma das paredes axiais com e sem canaletas axiais proximais, de 0,7mm de profundidade e 4mm de altura. A altura cérvico-oclusal dos preparos foi de 5mm e as dimensões mésio-distais e vestíbulo-linguais em 10mm e 7mm, respectivamente. Para a avaliação de resistência ao deslocamento, os corpos de prova adaptados em seus respectivos preparos, foram submetidos à cargas verticais de intensidade 3kg, 5kg, 10kg e 15kg em uma máquina de teste universal, com velocidade constante em 0,5mm/min., aplicadas nas vertentes internas das cúspides f!1ésio-linguais e médio-vestibulares. O registro dos resultados consistiu em visualizar a ocorrência ou não de deslocamento dos corpos de prova. Os resultados obtidos revelaram que: a) o aumento do ângulo de convergência entre as paredes axiais promove uma diminuição da estabilidade mecânica das coroas; b) com 6° e 8° de convergência em cada uma das paredes axiais ocorreu uma estabilidade mecânica ótima nas preparações sem canaletas; c) em 12° e 16° de convergência foi observada falta de estabilidade mecânica nas preparações sem canaletas; d) a utilização de canaletas axiais proximais constitui-se num efetivo meio para otimizar a estabilidade mecânica / Abstract: The objective of this work, was to evaluate the influence of the convergece angle between the axial walls of full crown preparations and the presence of proximal axial grooves, on the resistence form of full crows, without interlocking a cement medium. Eighty full crown preparations was màde with axo-proximal angles in natural teeth. Fourty with proximal axial grooves and fourty without proximal axial grooves. The preparations with showder larger 90° , was made with the following convergeces: 6°,8°, 12° and 16° in each of the axial walls, with and without proximal axial wals, of 0,7mm deep and 4mm high. The cervico-occlusal heigth of the preparations was 0,5mm and the mesio-distal and bucco-ligual diameters, 10mm and 7mm respectively. To evaluate the resistence form, the patterns adjusted in yours respective preparations, was submited to vertical forces of intensity 3kg, 5kg, 10kg and 15kg in a universal test machine, with speed in 0,5mm/min., applied in the internal vertent of the mesio-lingual and medio-buccal cuspals. The record of the results was to observe the occcurs of dislocation of the paterns. The obtained results shows that: a) the increase of the convergence angle promoves the decrease of the mechanical stabilty of the crowns; b) In 6° and 8° occured a optimal mechanical stability in the preparations without grooves; c) In 12° and 16° was observed the absence of stability in preparations with out grooves; d) The utilization of the proximal axial grooves is a effective option to optimize the mechanical stability, in preparations where the convergence angle is excessive / Mestrado / Protese Dental / Mestre em Clínica Odontológica
4

Influência do tipo de substrato dental e da espessura oclusal de coroas totais de cerâmica na sua resistência à compressão

Barros, Beatriz Álvares Cabral de January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-21T17:10:23Z (GMT). No. of bitstreams: 1 221028.pdf: 1129618 bytes, checksum: 81e727920ff7032cda279171cc130cef (MD5) / Através deste estudo, in vitro, avaliou-se a influência do tipo de substrato dental e da espessura oclusal de coroas totais cerâmicas na sua resistência à compressão. Quarenta molares hígidos extraídos foram limpos, fixados em resina acrílica autopolimerizável na porção radicular até 2mm aquém do limite esmalte-cemento, e mantidos em água à temperatura ambiente. Os espécimes receberam preparo tipo coroa total. Na oclusal, 20 dentes foram desgastados até a dentina e 20 dentes até esmalte. A redução axial foi de 1,5 mm com
5

Analise comparativa da alteração dimensional de materiais de moldagem elastomericos, atraves da tecnica do casquete

Andrade, Cicero Almeida de 18 August 2000 (has links)
Orientador: Frederico Andrade e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T01:43:10Z (GMT). No. of bitstreams: 1 Andrade_CiceroAlmeidade_D.pdf: 3205522 bytes, checksum: 84f534ad54ea83a4ce26950ae4eb5802 (MD5) Previous issue date: 2000 / Resumo: O presente estudo avaliou comparativamente a alteração dimensional de quatro materiais de moldagem elastoméricos de consistência fluida (uma silicona por adição, duas siliconas por condensação e uma mercaptana) através da técnica do casquete. Um modelo metálico (padrão) foi confeccionado contendo dois dentes com preparos tipo coroa total. Sobre este modelo, com um alívio metálico de 0,3mm, foram obtidos os casquetes através da técnica de Neelon (técnica do pincel). As moldagens foram realizadas através de uma prensa de carga estática onde uma força de 0,4 kgf assentava as moldeiras sobre o modelo metálico. As faces oclusais dos dentes preparados possuíam ranhuras, em forma de cruz. Na extremidade de cada ranhura havia pequenos pontos a partir dos quais iniciava-se a leitura. A leitura linear, em microscópio comparador, era feita inicialmente na face oclusal de cada dente distintamente, em seguida lia-se ligando os pontos entre os dois dentes. Os resultados foram analisados estatisticamente e concluiu-se que: não houve diferenças estatisticamente significantes / Abstract: The present study assessed comparatively the dimensional change of four fluid-consistence elastomeric impression materiais (one addition silicone, two condensation silicones and one mercaptan) using the headcap technique. A metal cast (pattern) was made, enclosing two teeth with metal-crown preparation. On this cast, with a O,3-mm metal relief, were obtained the headcaps using Neelon's technique (brush method). The impressions were carried out with a static-weight press, where a strength of 39.2 N (newton) was pressing the trays over the metal cast. The occlusal surfaces of the prepared teeth had cross-wise grooves. In the extreme of each groove there were small points where the reading started. The linear reading, in a comparing microscope, was initially done at the occlusal surface of each teeth distinctly, so following it was read matching the points between the two teeth. The results were statistically analysed and it followed that there were no statistically significant differences / Doutorado / Protese Dental / Doutor em Odontologia
6

Influência do tratamento de superfície pós condicionamento e da ciclagem termomecânica na resistência à fratura de coroas cerâmicas

Marinho, Caroline Cotes [UNESP] 06 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-06Bitstream added on 2014-06-13T19:58:19Z : No. of bitstreams: 1 marinho_cc_me_sjc.pdf: 660118 bytes, checksum: 0aaf49ff90e4b149760449933e8ac2a2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a resistência à fratura de coroas cerâmicas à base de dissilicato de lítio (IPS e.max CAD) submetidas a neutralização do precipitado do ácido fluorídrico (HF) associada ao banho ultrassônico, e envelhecidas por meio de ciclagem termomecânica. Quarenta molares humanos receberam um preparo convencional para coroa total após terem sido incluídos em um padrão de poliuretano com a simulação do ligamento periodontal. Após escaneamento digital dos preparos, os blocos cerâmicos foram usinados pelo sistema CAD/CAM para obtenção das coroas. As mesmas foram distribuídas nos grupos conforme o tratamento de superfície a saber: Grupos 1 e 3 - HF + silano; Grupos 2 e 4 - HF + neutralização do precipitado do ácido fluorídrico + banho ultrassônico + silano. As coroas foram cimentadas com cimento resinoso dual e os espécimes dos grupos 3 e 4 foram submetidos à ciclagem termomecânica (5 / 55 °C / 60 s enquanto ocorria 1.200.000 ciclos mecânicos de 4 Hz com carga de 100 N). As amostras foram submetidas ao ensaio de compressão, com carga aplicada no centro da face oclusal da coroa até a fratura. A análise das fraturas foi realizada macroscopicamente (método de Burke) e em um Microscópio Eletrônico de Varredura. Os dados de resistência a fratura foram submetidos ao teste estatístico de análise de variância dois fatores. Não houve diferença estatística entre os grupos estudados, independente da realização de ciclagem termomecânica ou de tratamento de superfície pós condicionamento proposto (p-valor = 0,8409). A maioria das falhas foi associada com a fratura do remanescente dentário, sendo que a origem da fratura estava localizada na superfície de cimentação. Foi concluído que a resistência à fratura de coroas cerâmicas para dentes posteriores a base... / The aim of this study was to evaluate the fracture resistance of lithium disilicate ceramic crowns (IPS e.max) subjected to neutralization of hydrofluoric acid (HF) associated with ultrasonic bath and aged by thermomechanical cycling. Forty human molar were prepared to receive a full crown after being included in a standard polyurethane with a simulation of the periodontal ligament. After the digital scanning of the prepared teeth, ceramic blocks were machined by CAD / CAM system to obtain the crowns. Then, they were distributed in groups according to surface treatment as follows: Groups 1 and 3 - HF + silane; Groups 2 and 4 - HF + neutralization + ultrasonic bath + silane. The crowns were cemented with dual-resin cement and the specimens of groups 3 and 4 were submitted to thermomechanical cycling (5 / 55 ° C for 60 s while the mechanical cycling of 1.200.000/ 4 Hz /100 N is occurring). Subsequently, the specimens were subjected to a mechanical test, with a compressive load applied at the center of the crown's occlusal surface until fracture. The fractograpy analyses was performed macroscopically (Burke method) and in a Scanning Electron Microscope. The values of fracture resistance were submitted to a statistical test ANOVA two factors. There was no statistical difference between the groups, regardless of surface treatment or thermomechanical cycling (p-value = 0,8409). Most of the failures were associated with tooth remaining fracture, and the origin of the fracture was located on the cementation surface. It was conclude that the fracture resistance of lithium disilicate posterior ceramic crowns is not influenced by the association between neutralization and ultrasonic bath, and the thermomechanical... (Complete abstract click electronic access below)
7

Influência da profundidade da parede gengival sobre a resistência a compressão e tipo de fratura de inlays cerâmicas em molares humanos

Santos Neto, Cássio dos 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T04:31:01Z (GMT). No. of bitstreams: 1 286306.pdf: 2010453 bytes, checksum: 4a495f845c67c50f6146e6810860ef4b (MD5) / Este estudo, in vitro, avaliou a influência da profundidade da parede gengival sobre a resistência a compressão e sobre o tipo de fratura de inlays cerâmicas em molares humanos. Cinquenta molares hígidos foram limpos e divididos em 5 grupos. Os dentes foram fixados em anéis de PVC, com resina acrílica autopolimerizável na porção radicular a 2 mm da junção amelocementária. Os espécimes receberam preparos do tipo inlay mésio-oclusodistal (MOD), com caixa oclusal apresentando profundidade de 2 mm do sulco principal até a parede pulpar, com ângulos internos arredondados e com as paredes com uma expulsividade entre 10º e 12º. Fez-se a divisão dos grupos segundo o tipo de preparo cavitário: grupo 1 desgaste axial de 1,5 mm; grupo 2 desgaste axial de 1,0 mm; grupo 3 desgaste axial de 2,0 mm; grupo 4 desgaste axial de 2,0 mm, realizando-se um núcleo de preenchimento com resina composta, a fim de reconstruir a parede pulpar e o ângulo axiopulpar, o que resultou em uma caixa de 1,5 mm; e grupo 5 desgaste axial de 2,0 mm, realizando-se um núcleo de preenchimento com resina composta, com largura das caixas de 1,5 mm, mas cujo núcleo de preenchimento foi removido em momento antecedente à cimentação, de forma a promover um espaço entre a cerâmica e o substrato dental de 0,5 mm, o qual o cimento, supostamente, preencheria. Após a realização dos preparos cavitários, estes foram moldados, e as restaurações cerâmicas foram confeccionadas e cimentadas. Após 24 h de armazenamento em água, os espécimes foram submetidos ao teste de compressão e aos testes estatísticos ANOVA e Mann-Whitney. Resultados: grupo 1 1,689 kN; grupo 2 1,470 kN; grupo 3: 1,563 kN; grupo 4 1,525 kN; grupo 5 1,526 kN. As fraturas mais frequentes, nos grupos 1, 2, 4 e 5, foram as dos tipos IV e V. Já para o grupo 3 as fraturas mais recorrentes foram as do tipo III.
8

Influência do tratamento de superfície e do tipo de cimento na retenção de coroas YTZP

Rippe, Marília Pivetta [UNESP] 28 November 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:51:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-11-28Bitstream added on 2014-08-13T17:59:34Z : No. of bitstreams: 1 000776628.pdf: 1391190 bytes, checksum: 0560fce743da2fc01c2682581e067e18 (MD5) / Comparar a retenção de coroas de zircônia YTZP em função do protocolo de cimentação. Foram preparados para coroa total 108 molares extraídos (n = 12). Pinos de fibra de vidro foram cimentados e núcleos de resina composta construídos. Infraestruturas de zircônia YTZP foram fresadas e 72 espécimes foram alocados em 6 grupos conforme os fatores: cimento - Multilink (Mult) e Relyx ARC (Rel); e tratamento de superfície da zircônia – álcool (controle) (C), silicatização (S) e vitrificação (V). Os outros 36 espécimes foram divididos em 3 grupos cimentados com Relyx Luting (Ion), Relyx U100 (Self) e fosfato de zinco (Zinc) sem tratamento da zircônia. Todos os espécimes foram termociclados (5 - 55 ºC, 6000 ciclos) e os dados do teste de tração foram analisados pelo teste de Kruskal Wallis e Dunn. Os valores da mediana e distância interquartil foram os seguintes: MultC: 20,0 (± 5,5); MultS: 28,5 (± 22,0); MultV: 32,5 (± 28,5); RelC: 21,5 (± 8,5); RelS: 22,0 (± 10,0); RelV: 24,0 (± 7,3); Ion: 5,1 (± 6,4); Self: 3,5 (± 5,2); Zinc: 7,7 (± 14,2). O tipo de cimento resinoso (a base de Bis-GMA e HEMA) não afetaram os valores de retenção das coroas. O tratamento de superfície da cerâmica vitrificação somente foi capaz de melhorar os valores de retenção para o cimento a base de HEMA. Para superfícies cerâmicas não tratadas, os cimentos resinosos mostraram significantemente maiores valores de retenção do que aqueles obtidos para os cimentos auto-adesivo, de inonômero de vidro e de fosfato de zinco / To compare the retention of YTZP zirconia crowns cemented to different cementation protocols. 108 extracted molars were prepared for full crown (n = 12); and the core was reconstructed with glass fiber post and composite resin core. YTZP zirconia copings were milled and 72 specimens were divided into 6 groups according to the factors: cements- Multilink (Mult) and Relyx ARC (Rel); and zirconia surface treatments- alcohol (control) (C), silica coating (S) and vitrification (V). The remaining 36 specimens were divided into 3 groups cemented with Relyx Luting (Ion), Relyx U100 (Self) and Zinc phosphate (Zinc) on untreated zirconia. The specimens were thermally cycled (5 - 55 °C, 6000 cycles) and data from the tensile test were analyzed by Kruskal Wallis and Dunn test. The median and interquartil range were: MultC: 20.0 (± 5.5); MultS: 28.5 (± 22.0); MultV: 32.5 (± 28.5); RelC: 21.5 (± 8.5); RelS: 22.0 (± 10.0); RelV: 24.0 (± 7.3); Ion: 5.1 (± 6.4); Self: 3.5 (± 5.2); Zinc: 7.7 (± 14.2). The type of resin cement (BIS-GMA- or HEMA- based) did not affect the crown retention values. The treatment involving vitrification of the cementation surface was only capable to improve the retention force for the HEMA based-cement. For untreated intaglio surfaces of YTZP crowns, resin cements showed significantly higher retention than those obtained for self-adhesive, glass ionomer and zinc phosphate cements
9

Análise comparativa da alteração dimensional de materiais de moldagem elastoméricos, através da técnica do casquete

ANDRADE, Cícero Almeida de 18 September 2000 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2018-05-28T14:00:19Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseComparativaAlteracao.pdf: 3204817 bytes, checksum: ecfafd4e0114abd00d4ab9a4a17078d4 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-06-01T18:20:59Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseComparativaAlteracao.pdf: 3204817 bytes, checksum: ecfafd4e0114abd00d4ab9a4a17078d4 (MD5) / Made available in DSpace on 2018-06-01T18:20:59Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseComparativaAlteracao.pdf: 3204817 bytes, checksum: ecfafd4e0114abd00d4ab9a4a17078d4 (MD5) Previous issue date: 2000-09-18 / O presente estudo avaliou comparativamente a alteração dimensional de quatro materiais de moldagem elastoméricos de consistência fluida (uma silicona por adição, duas siliconas por condensação e uma mercaptana) através da técnica do casquete. Um modelo metálico (padrão) foi confeccionado contendo dois dentes com preparos tipo coroa total. Sobre este modelo, com um alívio metálico de 0,3mm, foram obtidos os casquetes através da técnica de Neelon (técnica do pincel). As moldagens foram realizadas através de uma prensa de carga estática onde uma força de 0,4 kgf assentava as moldeiras sobre o modelo metálico. As faces oclusais dos dentes preparados possuíam ranhuras, em forma de cruz. Na extremidade de cada ranhura havia pequenos pontos a partir dos quais iniciava-se a leitura. A leitura linear, em microscópio comparador, era feita inicialmente na face oclusal de cada dente distintamente, em seguida lia-se ligando os pontos entre os dois dentes. Os resultados foram analisados estatisticamente e concluiu-se que: não houve diferenças estatisticamente significantes. / The present study assessed comparatively the dimensional change of four fluid-consistence elastomeric impression materiais (one addition silicone, two condensation silicones and one mercaptan) using the headcap technique. A metal cast (pattern) was made, enclosing two teeth with metal-crown preparation. On this cast, with a 0,3-mm metal relief, were obtained the headcaps using Neelon's technique (brush method). The impressions were carried out with a static-weight press, where a strength of 39.2 N (newton) was pressing the trays over the metal cast. The occlusal surfaces of the prepared teeth had cross-wise grooves. In the extreme of each groove there were small points where the reading started. The linear reading, in a comparing microscope, was initially done at the occlusal surface of each teeth distinctly, so following it was read matching the points between the two teeth. The results were statistically analysed and it followed that there were no statistically significant differences.
10

Análise da interface adesiva entre cimentos resinosos e diferentes terços da dentina intrarradicular

Suzuki, Thaís Yumi Umeda [UNESP] 18 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-18Bitstream added on 2014-06-13T19:16:55Z : No. of bitstreams: 1 suzuki_tyu_me_araca.pdf: 994382 bytes, checksum: 75c8c1831c920cfd4ce4e1f797803c6c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O propósito deste estudo foi avaliar as técnicas de cimentação adesiva de pinos de fibra de vidro nos diferentes terços da dentina intrarradicular, através da resistência de união e avaliação de propriedades mecânicas da interface adesiva. Quarenta dentes humanos unirradiculares foram utilizados neste estudo. Após obturação endodôntica e preparo mecânico dos condutos radiculares, os dentes foram divididos em cinco grupos experimentais (n=8), de acordo com a técnica adesiva adotada para cimentação de pinos de fibra de vidro: Grupo 1: adesivo fotoativado Single Bond 2 + cimento resinoso RelyX ARC; Grupo 2: adesivo dual Excite DSC + RelyX ARC; Grupo 3: adesivo autocondicionante Adper SE Plus + RelyX ARC; Grupo 4: cimento resinoso autoadesivo RelyX Unicem; Grupo 5: cimento resinoso autoadesivo Set. As propriedades mecânicas de dureza e módulo de elasticidade foram mensuradas nas estruturas da interface adesiva em ultramicrodurômetro digital DUH-211. A resistência de união foi mensurada pelo teste de push-out em máquina de ensaio universal nos diferentes terços da dentina intrarradicular (cervical, médio e apical). Os dados de resistência de união e propriedades mecânicas foram submetidos a testes estatísticos de normalidade e analisados pela ANOVA e teste de Fisher ( = 0,05). Os resultados mostraram que as propriedades mecânicas de dureza Martens e módulo de elasticidade dos materiais adesivos e do substrato dentinário são influenciados pela interação dos materiais resinosos utilizados, bem como pela profundidade intrarradicular. O mesmo fenômeno foi observado no teste de resistência de união. Para os materiais resinosos, houve uma tendência de o terço apical apresentar os menores valores das propriedades analisadas, o que poderia conduzir à realização de preparos intrarradiculares mais conservativos / The purpose of this study was to evaluate techniques for adhesive cementation of glass fiber posts in different thirds of intra-root dentin, through the bond strength and evaluation of mechanical properties of the adhesive interface components. Forty extracted single-rooted human teeth were used in this study. After endodontic filling and mechanical preparation of root canal, teeth were divided into five groups (n=8), according to the technique adopted for adhesive cementation of glass fiber posts: Group 1: Single Bond 2 light-cured adhesive + RelyX ARC resin cement; Group 2: Excite DSC dual adhesive + RelyX ARC; Group 3: Adper SE Plus self-etch adhesive + RelyX ARC; Group 4: RelyX Unicem self-adhesive resin cement; Group 5: Set selfadhesive resin cement. The mechanical properties of Martens hardness and elastic modulus were measured in the structures of the adhesive interface in a DUH-211 digital ultramicro hardness tester (Shimadzu). Push-out bond strength was measured in a universal testing machine (Emic DL 3000) in different areas of intra-root dentin (cervical, middle and apical). The data of bond strength and mechanical properties were subjected to statistical tests of normality and analyzed by ANOVA and Fisher’s test ( =0.05). The results showed that the mechanical properties of Martens hardness and elastic modulus of the adhesive materials and dentin substrate can be influenced by the interaction of the materials, as well as the depth of intraradicular dentin. The same phenomenon was observed in the push-out bonding strength test. There was a tendency of the apical region show the least values of mechanical properties, which could stimulate the use of more conservative intraradicular preparation

Page generated in 0.0721 seconds