• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 1
  • Tagged with
  • 43
  • 43
  • 16
  • 16
  • 15
  • 15
  • 13
  • 10
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação in vitro da adaptação marginal e interna de coroas cerâmicas confeccionadas com sistemas injetável e CAD/CAM

Barbosa, Marcelo Taveira January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-24T05:53:11Z (GMT). No. of bitstreams: 1 261617.pdf: 209674076 bytes, checksum: 97fab5d2cab78de257974f8abd912561 (MD5) / O objetivo deste estudo in vitro foi avaliar a adaptação marginal e interna de coroas cerâmicas confeccionadas com três sistemas cerâmicos. Dez molares humanos receberam preparo para coroa total. Para cada molar foram confeccionadas três diferentes coroas cerâmicas, uma coroa cerâmica obtida com a fresagem de blocos de ProCAD pelo sistema CAD/CAM Cerec 3, uma pelo sistema CAD/CAM Cerec in-Lab com infra-estruturas cerâmicas obtidas com a fresagem de blocos de IPS e.max ZirCAD e cobertura de IPS e.max Ceram, e uma pelo sistema injetável com infra-estrutura de IPS Empress 2 e cobertura com cerâmica IPS e.max Ceram. Antes do ajuste interno, foi realizada a avaliação da adaptação marginal com a mensuração da discrepância marginal absoluta de réplicas de resina epóxica das faces vestibular, lingual, mesial e distal por meio de microscópio eletrônico de varredura (MEV). Após o ajuste interno, novas réplicas foram realizadas para as mensurações da discrepância marginal absoluta. A diferença entre essas mensurações permitiu determinar a influência do ajuste interno. A avaliação da adaptação interna foi avaliada com a simulação de cimentação com um silicone de adição. As réplicas internas foram seccionadas nos sentidos mésio-distal e vestibulolingual. Em cada plano foram realizadas 12 mensurações da espessura de película de silicone, totalizando 24 mensurações por coroa. O teste de Wilcoxon pareado (Wilcoxon sign rank test) foi aplicado para as comparações entre os grupos. Os valores médios e o desvio padrão das discrepâncias marginais absolutas das coroas após o ajuste interno foram de 77,0 µm ± 13,7 µm para o grupo Cerec 3, de 60,8 µm ± 19,8 µm para o grupo Cerec in-Lab e de 58,4 µm ± 18,2 µm para o grupo injetável. Entretanto, não houve diferença estatística significativa entre os grupos. Os valores médios e os desvios padrão da espessura de película na cervical foram de 52,3 µm ± 17,1 µm para o grupo injetável, de 58,1 µm ± 15,7 µm para o grupo Cerec in-Lab e de 62,8 µm ± 10,1 µm para o grupo Cerec 3. O ajuste interno das coroas diminuiu em 36,6% os valores médios de adaptação externa de todos os grupos, quando foi repetido por duas vezes. Após o ajuste interno, todas as coroas cerâmicas apresentaram valores de discrepância marginal absoluta inferiores a 120 µm, considerados clinicamente aceitáveis.
32

Influência do núcleo de preenchimento na resistência à fratura de coroas de IPS-Empress 2 em pré-molares humanos

Fortkamp, Saulo January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T01:28:03Z (GMT). No. of bitstreams: 1 205752.pdf: 3690913 bytes, checksum: ed36ad33426221f38c4386e4b3f8b4a5 (MD5) / O objetivo deste estudo foi avaliar a influência de diferentes formas de núcleo de preenchimento na resistência à fratura de coroas de IPS-Empress 2 (EMP2). Quarenta pré-molares foram divididos aleatoriamente em 4 grupos. Os grupos foram restaurados da seguinte forma: Grupo 1, dentes com remoção total da coroa, restaurados com pinos fibro-resinosos (PFR) e núcleos de resina composta (NRC), apresentando preparos para coroas totais (PCT) de EMP2; Grupo 2, dentes com remoção parcial da coroa, restaurados com PFR e NRC, apresentando PCT de EMP2; Grupo 3; dentes com remoção parcial, restaurados com PFR e NRC, apresentando PCT de EMP2; e Grupo 4, dentes apenas com PCT de EMP2. Os espécimes foram submetidos à carga compressiva e não foi constatada nenhuma diferença estatisticamente significativa entre os grupos.
33

Influência da geometria oclusal e material restaurador na carga para fratura e distribuição de tensões em coroas totais

Lima, Aline Lins de [UNESP] 04 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-04. Added 1 bitstream(s) on 2015-09-17T15:47:29Z : No. of bitstreams: 1 000843165.pdf: 1705816 bytes, checksum: 5a38a920fb4dd4e8ebae58002b4a1b6d (MD5) / Este estudo avaliou a influência de diferentes padrões de altura de cúspides de restaurações totais fornecidos pelo banco de dados do sistema CAD/CAM CEREC (Jovem, Asiático e Adulto) na carga para fratura de dois materiais restauradores (resina acrílica e cerâmica). Sessenta preparos para coroa total em G10 (tecido de fibra de vidro impregnado com resina epóxi substituto personalizado da dentina) foram digitalizados pelo. CEREC e divididos em três grupos segundo os padrões oclusais fornecidos pelo banco de dados do CEREC de acordo com as diferentes alturas de cúspide: Jovem (J), Asiático (As) e Adulto (Ad). Cada padrão oclusal foi usinado com dois tipos de materiais diferentes: um com baixo módulo elástico (6 ± 0.5GPa) resina acrílica CAD-Waxx(R) e outro com alto módulo elástico (63 ± 0.5GPa) cerâmica feldspática VITA Mark II(C). Os preparos em G10 foram incluídos em resina de poliuretano e foram simulados alvéolos artificiais com poliéter de consistência leve. Todas as coroas foram cimentadas com cimento resinoso dual RelyX ARC® e armazenadas em água destilada por 24 h. Os corpos-de-prova foram submetidos ao teste de carga para fratura utilizando uma máquina de ensaios universal (EMIC - DL1000MF) com célula de carga de 1000 kgf a uma velocidade de 1.0 mm/min. Diferentes tipos de fratura foram obtidos e então classificados em cinco padrões: 1 (envolvendo o sulco central), 2 (envolvendo cúspides disto-lingual e disto-vestibular), 3 (envolvendo a cúspide disto-lingual), 4 (envolvendo sulco central e sulco lingual) e 5 (fratura em diversas partes). As médias e valores de carga para fratura, dados em Newton (N), foram analisados estatisticamente por meio dos testes ANOVA e Tukey (5%). O teste ANOVA dois fatores mostrou diferença estatisticamente significante para os fatores testados e o efeito interação (p < 0.05). As médias, desvios-padrões e resultados do teste de Tukey foram os seguintes: R/J- 2007.0 N ±... / This study assessed the influence of different cuspal patterns of total restorations provided by the database CEREC CAD/CAM system (Young, Asian and Adult shape) on load-to-fracture of two restorative materials (resin or ceramic). Sixty anatomic total crown preparations in G10 (customized Dentin Substitute) were scanned with CEREC and divided in three groups according to the occlusal pattern from CEREC database with different cusp heights: Young (Y), Asian (As) and Adult (Ad). Each occlusal pattern was machined with two different types of materials: one with a low-elastic modulus (6 ± 0.5GPa) CAD-Waxx resin (R) and another with a high-elastic modulus (63 ± 0.5GPa) VITA Mark II ceramic (C). The G10 specimens were embedded in polyurethane and artificial alveoli were simulated using a polyether. All crowns were cemented with resinous dualcure cement and stored in distilled water for 24 h. The specimens were load to fracture using a universal testing machine (EMIC- DL1000MF) with a load-cell of 1000 kgf at a crosshead speed of 1.0 mm/min. The fracture type was classified in five patterns: 1 (involving the central sulcus), 2 (involving distal-lingual and distal-buccal cusps), 3 (involving the lingual cusp), 4 (involving the central and lingual sulcus), and 5 (crown fractured in several parts). Load fracture means were analyzed with ANOVA and tukey's tests(5%). ANOVA two-way showed significant differences for the tested factors and for their interaction (p < 0.05). The means ± SD and results of tukey's test were: R/Y- 2007.0 ± 345.0a, R/As 742.6 ± 142.0b, R/Ad 1139.0 ± 132.0c, C/Y- 454.2 ± 77.5d, C/As 590.9 ± 94.3b, C/Ad 1149,4 ± 201.0c (different letters mean significant differences). The Adult pattern showed predominantly type 1 fractures for CAD-Waxx and type 5 for VITA Mark II. For the Asian pattern, type 3 was predominant for both materials. For the Young pattern, similar percentage for type 1 and 2 for CAD-Waxx, While for VITA.....
34

Influência do acabamento de preparos para coroas totais com microscópio operatório na adaptação marginal de restaurações em cerâmica tipo CAD-CAM

Oliveira, José Pedro Peixoto de January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:16Z (GMT). No. of bitstreams: 2 000399743-0.pdf: 674310 bytes, checksum: 694cbc44bc682f21bed71e69a6f99e90 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study assessed the marginal adaptation of full crown Lava (3M/ESPE) zirconium infrastructure under three different finishing instruments. Thirty human premolars, extracted for therapeutic reasons, were fixed in acrylic resin platforms. The teeth were randomly assigned to three groups (n=10) according the proceedings to cut a full crown preparation: Group 1 - diamond bur; Group 2 - diamond bur and 12-bladed finishing bur; Group 3 - diamond bur and a 12-bladed finishing bur under a 12. 5 X magnification operating microscope. Impressions were taken with an addition silicone material and dies were formed with a special stone. The dies were sent to 3M/ESPE laboratory to have a Lava zirconium infrastructure machined to each specimen. The copings were cemented to the corresponding tooth with RelyX Unicem cement. The restored specimens were embedded in acrylic resin and cut mesio distally and buccal lingually. Eight surfaces were observed with a stereomicroscope at x70 and digital images were obtained. The marginal adaptation measurements were carried out in the Image Tool program. According to ANOVA and Tukey´s test (α=0. 05), there was no statistic difference between Group 1 (88. 601 μm) and Group 2 (90. 946 μm). The lowest mean was obtained for Group 3 (58. 497 μm), and this mean was statistically different than those groups. It was concluded that the operating microscope provided better marginal adaptation of the Lava copings. / Este estudo teve o objetivo de avaliar a adaptação de infra-estruturas de cerâmica Lava (3M/ESPE) com três diferentes tipos de acabamento em preparos para coroa total. Trinta pré-molares humanos, extraídos por razões terapêuticas, foram fixados em blocos de resina acrílica e divididos aleatoriamente em três grupos (n=10) de acordo com o procedimento para realizar os preparos: grupo 1 - ponta diamantada; Grupo 2 - ponta diamantada e broca multi-laminada; Grupo 3 - ponta diamantada e broca multi-laminada, sendo este último instrumento com o uso do microscópio operatório em aumento de 12,5 vezes. Os preparos foram moldados com silicone por adição e os modelos obtidos em gesso especial tipo IV. Os modelos foram enviados para o laboratório da 3M/ESPE, o qual confeccionou os casquetes de cerâmica Lava. As infra-estruturas foram cimentadas nos dentes preparados com RelyX Unicem, sendo então incluídos em blocos de resina acrílica e cortados em dois planos: mésio-distal e vestíbulo-lingual. Desta forma, obteve-se quatro fragmentos, sendo que cada fragmento forneceu duas regiões para observar a discrepância das margens. Por meio de lupa estereoscópica, acoplada a uma câmera de vídeo, foram obtidas imagens digitais da região das margens em aumento de 70 vezes. As medidas de adaptação marginal foram realizadas no programa Image Tool. De acordo com ANOVA e teste de Tukey (α=0,05), não houve diferença estatística entre os Grupo 1 (88,601 μm) e Grupo 2 (90,946 μm). A menor média foi obtida para o Grupo 3 (58,497 μm), diferindo estatisticamente dos outros dois grupos. Pôde-se concluir que o emprego do microscópio operatório favoreceu a melhor adaptação marginal nos casquetes de cerâmica Lava.
35

Avaliação da adaptação cervical de coroas totais metalicas com diferentes terminos antes e apos a cimentação

Brisolara, Paulo Gilberto da Silveira 27 September 2000 (has links)
Orientador: Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T00:03:33Z (GMT). No. of bitstreams: 1 Brisolara_PauloGilbertodaSilveira_M.pdf: 2380503 bytes, checksum: edcc34fb503e863b41cb601c8ce011ef (MD5) Previous issue date: 2000 / Resumo: o propósito deste estudo foi avaliar o ajuste cervical antes e após a cimentação de coroas totais metálicas confeccionadas com liga de níquel-cromo (Verabond 11), em preparos sobre dentes bovinos com diferentes términos cervicais: chanfro em 45° , ombro biselado em 20° e ombro reto, com os cimentos de fosfato de zinco, ionômero de vidro e resinoso. Noventa coroas totais metálicas foram fundidas com a liga de níquel-cromo (Verabond 11) utilizando o maçarico gás-oxigênio. Após a fundição, as coroas foram adaptadas sobre os preparos com carga estática de 9 kg. A discrepância marginal foi medida com micrômetro digital (Mitutoyo) e as coroas metálicas foram fixadas sobre os dentes com os cimentos de fosfato de zinco, ionômero de vidro e resinoso, manipulados de acordo com as recomendações dos fabricantes. Em seguida, a discrepância marginal foi medida novamente. Os resultados submetidos à análise de variância e ao teste de Tukey (5%) e indicaram que: antes da cimentação, o término cervical em ombro biselado em 20° mostrou a maior média de desajuste cervical, sendo diferente estatisticamente do chanfro em 45° e ombro reto, também diferentes entre si; após a cimentação, para cada tipo de cimento, o melhor ajuste cervical foi obtido com o término cervical em ombro reto, seguido pelo chanfro em 45° e ombro biselado em 20°; independente do término cervical, as coroas metálicas fixadas com o cimento de ionômero de vidro apresentaram os melhores resultados, seguido pelo cimento de fosfato de zinco e cimento resinoso / Abstract: The purpose of this study was to analyse the cervical fits before and after cementation of full cast crowns made with nickel-chromium alloy (Verabond 11), with three different marginal designs: 45-degree chamfered, 20-degree bevel shoulder and right shoulder, on the bovino teeth with zinc phosphate, glass ionomer and resin cements. Ninety crowns were cast with nickel-chromium (Verabond 11) melted by gas-oxygen torch. After casting the crowns were seated on different marginal configurations with a static load of 9 kg. The marginal discrepancy was measured before cementation using a digital micrometer (Mitutoyo). Afterwards, the crowns were luted onto the tooth with zinc phosphate, glass ionomer and resin cements mixed with standardized proportions and procedures, the marginal discrepancy was measured again. The results were submitted to analysis of variance and Tukey's test (5%) and indicated that before cementation the marginal designs: 20-degree bevel shoulder showed the most average cervical fits, being statistically different in relation to 45-degree chamfered and right shoulder, also different between them. After cementation, for each cement, the better fits were obtained with right shoulder in relation to 45-degree chamfered and 20 degree bevel shoulder. Independent of marginal configurations, the full cast crowns luted with glass ionomer cement showed the better cervical fits in relation to zinc phosphate and resin cements / Mestrado / Mestre em Materiais Dentários
36

Influencia de agentes cimentantes na resistencia a tração de coroas totais fundidas, fixadas em dentina e nucleos metalicos

Prates, Luiz Henrique Maykot 14 September 1999 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T17:22:10Z (GMT). No. of bitstreams: 1 Prates_LuizHenriqueMaykot_M.pdf: 4937964 bytes, checksum: 1759111268df7345a8f2609a47b24c1d (MD5) Previous issue date: 1999 / Resumo: O propósito do estudo foi avaliar o comportamento de 4 agentes cimentantes, em relação à resistência à remoção, por tração, de coroas totais fundidas, fixadas sobre preparos em dentina e núcleos metálicos. Foram utilizados 28 molares humanos, inferiores e recém-extraídos. Após a confecção de um orifício retentivo, as raízes dos dentes foram embutidas em resina acrílica ativada quimicamente, contida em tubos de PVC. Nas porções coronárias foram confeccionados preparos para coroas totais, com ponta diamantada n. 4103, sob refrigeração, acoplada ao torno mecânico. Os preparos em dentina, com expulsividade de 8°, foram reproduzidos em liga de prata Pratalloy (Degussa), através de técnica de fundição. Após a limpeza dos núcleos metálicos, com jato de óxido de alumínio, os preparos foram moldados com silicona por adição Express (3M), sendo o enceramento os padrões das coroas, realizado em troquéis de gesso tipo IV Vel Mix (Kerr). As 56 coroas totais, com uma alça suporte oclusal, foram confeccionadas em liga de paládio-prata Pors-on 4 (Degussa), através de técnica de fundição de rotina. Após a limpeza das coroas, com jato de óxido de alumínio, os corpos-de-prova em dentina e em núcleos, foram divididos aleatoriamente em 8 grupos com 7 réplicas (4 grupos em dentina e 4 em núcleos). As coroas dos grupos 1,2, 3 e 4 foram fixadas nos preparos em dentina, respectivamente, com os cimentos de fosfato de zinco (Cimento de Zinco - SS White); de ionômero de vidro convencional (Ketac Cem - ESPE); de ionômero de vidro modificado por resina (Vitremer - 3M); e, resinoso com adesivo (Cimento de Resina com Scotchbond Multi-Uso Plus - 3M). As coroas dos grupos 5, 6, 7 e 8 foram fixadas nos núcleos metálicos, respectivamente, com os mesmos cimentos. Os corpos-de-prova foram armazenados em 100 % de umidade relativa, a 37° C, durante 24 horas, sendo em seguida submetidos a 500 ciclos. ... Observação: O resumo, na integra, poderá ser visualizado no texto completo da tese digital / Abstract: The purpose of this study was to evaluate the behaviour of 4 dental cements, to the removal strength, under tensile, of full cast crowns luted to dentin, and cast metallic cores. Atier the preparation of a retentive orifices, the roots of twenty eight teeth were embedded in resin within PVC tubes. Then, the coronal portions of the teeth were prepared to receive full crowns, using a 4103 diamond bur, under refrigeration, held on a lathe. Dentin preparations, with 8 degrees of tapering, were duplicated with silver alloy (Pratalloy - Degussa), using a routine casting technique. The mettalic cores were cleaned with aluminum oxide blast, the preparations were cast with Express (3M) vinyl polysiloxane, and the patterns were waxed on type IV stone dies (Vel Mix - Kerr). The fifiy six full crowns, with an occlusal support loop, were ma de with palladium-silver alloy (Pors-on 4 - Degussa) using a routine casting technique. The mettalic crowns were cleaned with aluminum oxide blast, and then the test specimens on dentin and in cores were randomly assigned to 8 groups of 7 units each (4 groups in dentin and 4 groups in cores). The crowns of Groups 1, 2, 3 and 4 were luted to the preparations in dentin, respectively, with zinc phosphate (SS White), conventional glass ionomer (Ketac Cem ESPE), resin-modified glass ionomer (Vitremer - 3M) and resin with adhesive (Resin cement and Scotchbond MP Plus - 3M) cements. The crowns of Groups 5, 6, 7 and 8 were luted in metallic cores, respectively, with the same cements. All samples were stored at 370 C, in 100 % relative humidity, for 24 hours. ... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Materiais Dentários
37

Avaliação de diferentes métodos de obtenção do modelo virtual no sistema CAD/CAM CEREC por meio de microtomografia computadorizada

Carneiro, Thiago de Almeida Prado Naves 26 February 2013 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Objectives: The current study evaluated the different methods of virtual model obtention fabricated by CEREC CAD/CAM system, using micro-computed tomography to compare marginal gap on ceramic crowns. Methods: A human premolar (#21) was prepared for an all-ceramic crown. Twenty different digital impressions, designs and crowns were made by the CEREC CAD/CAM system after virtual model obtention by four different methods. The typodont, with the #21 (T), was powdered using a thin layer of titanium dioxide (Sirona) and scanned with the CEREC 3D BlueCam. Regular impressions (RI) were taken of the typodont and were scanned. Master casts (MC) were obtained and scanned. After that, the master casts were powdered (PMC) using a thin layer of titanium dioxide and scanned again. All the crowns were made by feldspathic ceramics (VITABLOCS Mark II) in the InLab milling unit - SIRONA. Each crown was fixed and scanned using a micro-CT to obtain images for marginal gap measurements. The Micro-CT allowed the measurement of marginal gaps at 52 locations in each specimen, totalizing 260 values of vertical misfit and 260 of horizontal misfit. Three calibrated examiners and the mean values were obtained. Results: Considering the percentage of vertical marginal gap up to 75 &#956;m, the results were: T 71.5%, RI 49.2%, MC 69.6% and PMC 71.2%. The percentages of horizontal measurements with overextension of the crowns were: T 8.5%, RI 0%, MC 0.8% and PMC 3.8%, and Conclusion: Based on the results of this study, obtaining virtual models by scanning the mouth or the master cast, with or without powder, showed acceptable values of marginal gap on feldspathic ceramic crowns (VITABLOCS Mark II) manufactured on chairside CEREC CAD/CAM system, considering up to 75&#956;m (our reference value). The higher results of marginal gap for regular impression suggest that is preferable to scan directly the mouth or the master cast. / Objetivos: O presente estudo avaliou diferentes métodos de obtenção do modelo virtual pelo sistema CEREC CAD/CAM, utilizando micro-tomografia computadorizada para comparar a desadaptação marginal em coroas de cerâmica pura obtidas pelo sistema. Métodos: um pré-molar humano (34) foi preparado para uma coroa de cerâmica pura. Impressões digitais, por quatro métodos diferentes foram feitas pelo sistema CEREC CAD / CAM, e as coroas projetadas após obtenção do modelo virtual. Para o grupo Boca (T), o dente humano montado em Typodont foi pulverizado usando uma fina camada de dióxido de titânio (Sirona) e digitalizado com o 3D CEREC BlueCam. Para o grupo Molde (RI), moldagens foram realizadas do Typodont e foram digitalizadas após aplicação de dióxido de titânio. Depois, os modelos de gesso (CM) foram obtidos, a partir destes mesmos moldes, e digitalizados. E por último, os modelos de gesso (PCM) já digitalizados foram submetidos à aplicação de dióxido de titânio e foram digitalizados novamente. Todas as coroas foram feitas por cerâmica feldspática (VITABLOCS Mark II) na unidade de usinagem InLab - Sirona. Cada coroa foi fixada e analisada usando um micro-CT para obter imagens para medições de fenda marginal. O Micro-CT permitiu a medida de desadaptações marginais em 52 locais em cada amostra, totalizando 260 valores de desajuste vertical e 260 de desajuste horizontal. Três examinadores calibrados fizeram as medições e os valores médios foram obtidos. Resultados: Considerando o percentual de fenda marginal vertical de até 75 &#956;m, os resultados foram: 71,5% T, RI 49,2%, 69,6% MC e PMC 71,2%. As porcentagens de medidas horizontais com sobre extensão das coroas foram: T 8,5%, RI 0%, 0,8% e MC PMC 3,8%. Conclusão: Com base nos resultados deste estudo, a obtenção de modelos virtuais, diretamente da boca ou de modelos de gesso, com ou sem aplicação de pó, apresentaram valores aceitáveis de desadaptação marginal em coroas de cerâmica feldspática (VITABLOCS Mark II), fabricadas em consultório pelo sistema CAD / CAM CEREC, considerando 75&#956;m (nosso valor de referência). Os valores mais elevados de desadaptação marginal foram encontrados na digitalização dos moldes e sugerem que é preferível digitalizar diretamente da boca ou de modelos de gesso. / Mestre em Odontologia
38

Resistencia de união e caracterização morfologica da dentina coronaria e radicular tratada com sistemas adesivos / Blond strenght and morphologic characterization of crown and root dentine treated with adhesive systems

Caiado, Ana Carolina Rocha Lima 26 February 2007 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T13:06:43Z (GMT). No. of bitstreams: 1 Caiado_AnaCarolinaRochaLima_M.pdf: 12410221 bytes, checksum: 10dff9d1f7b58797480e9a00a97d0a78 (MD5) Previous issue date: 2006 / Resumo: Este estudo teve como objetivos: (a) caracterizar a morfologia, a densidade e a área transversal de túbulos dentinários da dentina coronária (profunda) e radicular (terço cervical) intactas e após condicionamento com ácido fosfórico 32% (AF) e primer condicionante do sistema adesivo Clearfill Protect Bond (P); e (b) avaliar e comparar a resistência de união e os padrões de fratura obtidos na dentina coronária (profunda) e dentina radicular (terço cervical). Pré-molares humanos hígidos foram fixados em gluteraldeído (2,5%). Secções da dentina coronária profunda e dentina radicular (região cervical) foram obtidas por clivagem. Cada dente recebeu os seguintes tratamentos: G1- dentina coronária + AF; G2- dentina coronária + P; G3 - dentina coronária sem tratamento; G4- dentina radicular + AF; G5- dentina radicular + P; G6- dentina radicular sem tratamento. As secções condicionadas com primer foram imersas em etanol e acetona. Todos os grupos foram desidratados em concentrações ascendentes de álcool e HMDS e visualizadas por microscopia eletrÃ'nica de varredura em ampliação de 1500X. As imagens obtidas foram usadas para calcular a densidade (D) e a área (A) da secção transversal dos túbulos dentinários em µm2 utilizando o programa Leica IM50. Para o teste de microtração foram utilizados fatias de dentina coronária profunda e dentina radicular cervical de 12 dentes que foram divididas em quatro grupos de acordo com a região dentinária e o sistema adesivo utilizado: G7- dentina radicular + Single Bond II; G8- dentina radicular + Clearfill Protect Bond; G9- dentina coronária + Single Bond II; G10- dentina coronária + Clearfill Protect Bond. Resina composta foi acrescentada em ambos os lados das fatias. Foram obtidas dessas fatias espécimes em forma de palito. Após armazenamento em água (37ºC) os espécimes foram submetidos ao teste de microtração em uma máquina de ensaio universal (Instron), a uma velocidade de 0,5mm/min. A dentina radicular intacta do terço cervical apresentou uma superfície irregular formada por calcosferitos, o que a difere estruturalmente da dentina coronária. Já a densidade (42.627/mm2) e a área transversal média (2,9035/ µm2) dos túbulos dentinários na raiz não revelou diferença estatisticamente significante (p> 0,05) aos valores encontrados na coroa. Os dados de resistência de união foram estatisticamente superiores na dentina coronária (26.63 MPa) do que na dentina radicular (19.76 MPa). O padrão de fratura mais frequentemente encontrado para ambas as regiões foi a fratura mista (coesiva no adesivo e na camada híbrida). ÿ possível concluir que as dentinas coronária (profunda) e radicular do (terço cervical) apresentam diferenças morfológicas e nos valores de resistência de união, porém apresentam semelhanças quanto à densidade de túbulos e padrões de fratura independente do sistema adesivo utilizado / Abstract: The aim of this study was to: (a) characterize the morphology, density and transversal cross-section area of tubules of deep crown and cervical root dentine, intact and after etched with 32% phosphoric acid (AF) or the self-etch primer of the Clearfill Protect Bond adhesive system (P); and (b) evaluate and compare the bond strength and the fracture patterns obtained from deep crown dentine and cervical root dentine. Human carie-free premolars (n=5) were fixed in 25% glutaraldehyde. Deep crown and root dentine sections were obtained by cleavage. Each tooth was treated as follows: G1- crown dentine + AF; G2- crown dentine and P; G3-intact crown dentine; G4- root dentine + AF; G5- root dentine + P; G6- intact root dentine. The sections etched with primer were immersed in ethanol and acetone. All groups were dehydrated in increasing alcohol concentration and Hexamethyldisilazane, nd were visualized by Scanning Electron Microscopy. A magnification of 1500X was used to calculate the density (D) and the dentinal tubule transversal cross-section area per mm2, using the program Leica IM50. For microtensile testing, twelve premolars were cut to obtain slices of deep crown dentine and cervical root dentine. These were divided in four groups according to dentine region and adhesive system employed: G7- root dentine + Single Bond II; G8- root dentine + Clearfill Protect Bond; G9- crown dentine + Single Bond II; G10- crown dentine + Clearfill Protect Bond. Restorative was added to both sides of the slices. Beam specimens were obtained from these restored slices which were kept in water at 37ºC. The specimens were microtensile tested using a universal testing machine (Instrom) at a speed of 0,5mm/min. Intact cervical root dentine presented an irregular surface formed with calcospherites, demonstrating its structural difference from coronary dentine. On the other hand, root dentine tubule density (42,627/mm2) and average transversal area (2.9035/ µm2) did not reveal statistically significant difference (p>0.05) when compared to values obtain in crown. Bond strength results were statistically superior for crown dentine (26.63 MPa) then root dentine (19.76 MPa). Mixed fractures (cohesive in adhesive and hybrid layer) were the most frequent fracture patterns found for both regions. It is possible to conclude that deep crown dentine and cervical root dentine present morphological and bond strength differences, however, are similar in relation to tubule density and fracture patterns independent of the adhesive system employed. / Mestrado / Endodontia / Mestre em Clínica Odontológica
39

Influencia da altura do remanescente coronario, do tipo de retenção intra-radicular e do tipo de coroa total na resistencia e modo de fratura de raizes bovinas / Influence of coronal tooth structure, type of intraradicular retention and total crown on fracture strength and mode of failure of bovine roots

Resende, Cristina do Amparo 24 September 2007 (has links)
Orientadores: Luis Roberto Marcondes Martins, Carlos Jose Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T14:12:54Z (GMT). No. of bitstreams: 1 Resende_CristinadoAmparo_D.pdf: 3071325 bytes, checksum: 2b04a3fed0292eea5d925854e4ace595 (MD5) Previous issue date: 2007 / Resumo: O objetivo deste estudo foi avaliar a resistência à fratura de raízes bovinas tratadas endodonticamente e restauradas com diferentes retenções intra-radiculares variando-se o tipo de material da coroa total, na presença e ausência do remanescente coronário. Duzentas raízes com dimensões padronizadas foram divididas aleatoriamente em 20 grupos experimentais (n=10) nos seguintes tratamentos: retenções: pino de fibra de vidro (PFV), pino de fibra de vidro reembasado (PFVR), fibra de polietileno (FP), preenchimento do canal com resina composta (RC) e núcleo metálico fundido (NMF); remanescente: ausente ou com 2 mm de altura; coroa total: cerômero ou cerâmica pura. As coroas totais foram cimentadas com cimento resinoso e as raízes foram fixadas em resina poliestirênica, simulando-se o ligamento periodontal com material de moldagem à base de poliéter. As amostras foram submetidas ao carregamento tangencial de compressão, sob um ângulo de 135º a 0,5 mm/min até ocorrer a falha. Os resultados (ANOVA / Tukey a=0,05) demonstraram que houve diferença estatisticamente significante entre os tipos de pinos (p=0,0058), sendo os grupos restaurados com PFVR e RC apresentaram os maiores valores de resistência à fratura, não diferindo estatisticamente dos grupos restaurados com PFV e PF, e os grupos restaurados com núcleos metálicos fundidos apresentaram os menores valores, não diferindo estatisticamente dos grupos restaurados com PFV e PF. Para os tipos de coroa total (p<0,0001), os grupos restaurados com coroas em cerômero apresentaram maiores valores de resistência à fratura em relação aos grupos restaurados com coroas em cerâmica pura. Os grupos restaurados com fitas de fibra de polietileno mais frequentemente apresentaram padrão de fratura favorável, enquanto os restaurados apenas com resina composta apresentaram padrão de fratura desfavorável, seguidos dos núcleos metálicos fundidos. Para os tipos de coroa total, os grupos restaurados com coroas em cerâmica pura mais frequentemente apresentaram padrão de fratura favorável quando comparados aos grupos restaurados com cerômero, sendo que o mesmo ocorreu para os grupos sem remanescente coronário, quando comparados aos grupos com 2 mm de remanescente / Abstract: The objective of this study was to evaluate the fracture strength of bovine roots endodontically treated and restored by different intraradicular retention varying the type of material of the total crown, in presence or absence of the coronal tooth structure. Two hundred roots with standardized dimensions was divided randomly into 20 experimental groups (n=10) in the following treatments: retentions: fiber glass post, (PFV), relined fiber glass post (PFVR), polyethylene fiber ribbon post (FP), filling of root with composite resin (RC) and cast post and core (NMF); coronal remainder: absence or presence of 2 mm of coronal structure height; total crown: ceromer or all ceramic crown. Total crowns were luted with resin cement and the roots were fixed in resin blocks and artificial periodontal ligament was simulated with casting material made of polyether. The specimens were submitted to compressive strength test at 135º and 0,5 mm/min until fracture occurred. The results (ANOVA/Tukey a=0,05) showed that it had statistical significant difference among the types of retentions (p=0,0058), being the groups restored with PFVR and RC showed the higher failure loads, not differing statistically from groups restored by PFV and PF, and the groups restored by cast post and core showed lower failure loads, not differing statistically from groups restored by PFV and PF. For the types of total crown (p< 0.0001), the groups restored by ceromer crowns showed higher failure loads than did groups restored by all ceramic crowns. The groups restored by polyethylene fiber ribbon post more frequently showed favorable failure modes, while the restored ones only by composite resin showed unfavorable failure modes, followed by cast post and core. For the types of total crown, the groups restored by all ceramic crowns more frequently showed favorable failure modes than did groups restored with ceromer crowns, being that the same it occurred for the groups without coronal tooth structure, when compared to the groups with 2 mm of coronal structure height / Doutorado / Dentística / Doutor em Clínica Odontológica
40

Influência dos ciclos de cocção da porcelana na força de destorque de parafusos de estruturas implanto-retidas / Influence of porcelain fire cycles on detorque resistance of screws from implant-retained structures

Torres, José Walter Murta, 1958- 21 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:50:10Z (GMT). No. of bitstreams: 1 Torres_JoseWalterMurta_D.pdf: 1581851 bytes, checksum: 0bbcce2409164d19a4e51f955b38d595 (MD5) Previous issue date: 2013 / Resumo: Este trabalho avaliou a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr) após fundição e simulação dos ciclos de cocção da porcelana. Dois implantes hexágono externo - com 3,75 mm de diâmetro - foram posicionados, com o auxílio de um paralelômetro fresador (1000N; Bio-art), na posição de segundo pré-molar e segundo molar num troquel de resina acrílica, de maneira a ficarem parcialmente submersos na resina expondo apenas suas plataformas de adaptação. Foram confeccionados 10 troqueis de resina acrílica (n=10). A partir de cada troquel foi obtida, pelo método de fundição da cera perdida, uma infraestrutura implanto-retida utilizando-se dois cilindros calcináveis tipo UCLA. A amostra foi submetida à força de torque de seus parafusos de fixação a 20 Ncm, registrada por meio de um torquímetro digital de precisão (Torque Meter TQ-8800; Lutron), e reapertados após 10 minutos. A força de destorque foi registrada após 24 horas do torque inicial. A resistência ao destorque foi analisada após fundição da estrutura protética e simulação dos três ciclos de cocção da porcelana (opaco dentina e glaze). Foram obtidas médias de destorque para cada estrutura nas distintas etapas de avaliação no estudo. Os dados foram analisados estatisticamente pelos testes ANOVA one-way e Bonferroni, com nível de significância de 5% (p<0,05). Os valores das médias da força de destorque dos parafusos por fase foram 13,95 ± 1,12 Ncm para pós-fundição, 15,20 ± 1,18 Ncm para ciclo Opaco, 15,85 ± 1,13 Ncm para ciclo Dentina e 16,80 ± 1,03 Ncm para o glaze. A força de destorque dos parafusos após a fundição foi significativamente menor do que a obtida para os grupos que simularam o ciclo de cocção da porcelana (p<0,05). Entre as fases de simulação dos ciclos cerâmicos, observou-se maior valor da força de destorque para o glaze (p<0,05), não sendo observadas diferenças estatisticamente significantes entre as fases opaco e dentina (p>0,05). Foi possível verificar que os ciclos de cocção da porcelana influenciam a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr). Observou-se que os valores de destorque aumentaram gradativamente com cada ciclo de cocção da porcelana / Abstract: This study evaluated the resistance to detorque of screws from implant-retained metal structures cast in nickel-chromium (Ni-Cr) after metal casting and simulation of porcelain firing cycle. Two external hex implants - with 3.75 mm diameters - were placed with the help of a parallelometer cutter (1000N; Bio-art), in the position of second premolar and second molar in acrylic resin die, so as to be partially submerged in the resin exposing only their platforms for adaptation. Thereupon, 10 dies were made with acrylic resin (n= 10). An implant-retained infrastructure from each die was obtained by the method of lost wax casting, using two UCLA cylinders. The sample of acrylic structures were subjected to 20 Ncm of torque to its fixing screws registered by means of a precision digital torque wrench (Torque Meter TQ-8800; Lutron) and retightened after 10 minutes. The measure of detorque was recorded 24 hours after the initial torque. The detorque resistance was analyzed after denture casting, followed by the simulation of porcelain firing cycles (opaque, dentin and glaze). Detorque averages were obtained for each structure at different stages of evaluation in this study. Data was statistically analyzed by one-way ANOVA and Bonferroni tests, at 5% significance level (p>0.05). We performed necessary statistical tests. The mean detorque force of the screws per phase were 13.95 ± 1.12 Ncm for post-casting; 15.20 ± 1.18 Ncm for cycle opaque; 15.85 ± 1.13 Ncm for cycle dentin; and 16.80 ± 1.03 Ncm for glazing. The screw's post-casting detorque resistance was significantly lower than that observed for the groups simulating porcelain firing cycles (p<0.05). Among groups simulating ceramic's cycles, the highest detorque resistance was observed for glaze group (p<0.05), with no significant statistical differences among opaque and dentin groups (p>0.05). It was possible that the porcelain firing cycle influenced detorque resistance of screws in implant-retained metal structures cast in nickel-chromium (Ni-Cr). It was observed that detorque values gradually increased after each porcelain firing cycle / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.4614 seconds