• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do peróxido de carbamida em diferentes concentrações sobre a rugosidade superficial e brilho de uma cerâmica odontológica / The effect of carbamide peroxide in different concentrations on the surface roughness and gloss using dental ceramics

Ana Carolina Cabral Roque 22 January 2016 (has links)
O gel de peróxido de carbamida é utilizado em concentrações que variam de 10 a 35%, por períodos de 2 a 8 horas diárias e seu efeito sobre os materiais restauradores ainda não está totalmente elucidado. Assim, o objetivo desse estudo foi avaliar a ação do peróxido de carbamida, 10 e 16%, sobre a rugosidade superficial e o brilho de uma cerâmica odontológica feldspática. Foram confeccionados espécimes (n=10), com a cerâmica IPS d.SIGN , que foram submetidos a protocolos de aplicação de gel de peróxido de carbamida a 10 e 16%, nos tempos de 4 ou 3 horas diárias respectivamente, pelo período de 14 dias. A determinação da rugosidade e da alteração de brilho foi realizada no início do tratamento, após 07 e após 14 dias. A rugosidade superficial foi determinada pelo microscópio, LEXT 3D Measuring Laser Microscope OLS4000, OLYMPUS, e a leitura do brilho foi feita pelo aparelho Micro Gloss. Após a obtenção dos dados, foi realizada a análise TwoWay ANOVA, verificou-se que o resultado obtido foi estatisticamente significante para a variável de rugosidade, tanto para os fatores de variação de tempo (p = 0,004), concentração do peróxido de carbamida (p = 0,007) e para a interação entre ambos (p = 0,013). Foi feito o teste de múltiplas comparações com ajustes de Bonferroni, para análise dos resultados obtidos. Na análise do brilho, para os resultados encontrados, não houve diferença estatisticamente significante. Assim, pode-se concluir que o peróxido de carbamida 10% não provocou alterações significativas na rugosidade da cerâmica, mas o peróxido de carbamida a 16% provocou aumento da rugosidade após o período de 14 dias de aplicação, com médias em torno de 4,0 μm. Conclui-se, então, que as restaurações cerâmicas devem ser protegidas antes da aplicação de agentes clareadores à base de peróxido de carbamida 10 ou 16%. / The carbamide peroxide gel is used in concentrations ranging from 10 to 35% for periods from 2 to 8 hours daily and its effect on the restorative material isnt yet fully elucidated. The objective of this study was to evaluate the action of carbamide peroxide, 10 and 16%, on the surface roughness and the gloss of a feldspathic dental ceramics. Specimens were prepared (n = 10), IPS d.SIGN ceramics and submitted to carbamide peroxide gel application protocols 10 and 16% at 4 or 3 hours, respectively, at time 14 days. The determination of roughness and gloss was made at baseline, after 07 and after 14 days. The surface roughness was determined by microscope, 3D Measuring Laser Microscope OLS4000 LEXT, OLYMPUS, and the reading of the gloss was taken by Micro Gloss device. After obtaining the data, the TwoWay ANOVA analysis was performed, it was found that the obtained result was statistically significant roughness variable, both for time-variant factor (p = 0.004), concentration of the carbamide peroxide (p = 0.007) and the interaction between both (p = 0.013). It was made for multiple comparisons test with Bonferroni adjustments, for analysis of the results.There was no statistically significant difference in gloss. Thus, it can be concluded that the carbamide peroxide 10% did not cause significant changes in roughness ceramic, but the carbamide peroxide at 16% caused an increased roughness after 14 days of application, averaging around 4, 0 micrometers. Therefore, the ceramic restorations must be protected before the application of bleaching agents based on carbamide peroxide 10 or 16%.
2

Efeito do peróxido de carbamida em diferentes concentrações sobre a rugosidade superficial e brilho de uma cerâmica odontológica / The effect of carbamide peroxide in different concentrations on the surface roughness and gloss using dental ceramics

Roque, Ana Carolina Cabral 22 January 2016 (has links)
O gel de peróxido de carbamida é utilizado em concentrações que variam de 10 a 35%, por períodos de 2 a 8 horas diárias e seu efeito sobre os materiais restauradores ainda não está totalmente elucidado. Assim, o objetivo desse estudo foi avaliar a ação do peróxido de carbamida, 10 e 16%, sobre a rugosidade superficial e o brilho de uma cerâmica odontológica feldspática. Foram confeccionados espécimes (n=10), com a cerâmica IPS d.SIGN , que foram submetidos a protocolos de aplicação de gel de peróxido de carbamida a 10 e 16%, nos tempos de 4 ou 3 horas diárias respectivamente, pelo período de 14 dias. A determinação da rugosidade e da alteração de brilho foi realizada no início do tratamento, após 07 e após 14 dias. A rugosidade superficial foi determinada pelo microscópio, LEXT 3D Measuring Laser Microscope OLS4000, OLYMPUS, e a leitura do brilho foi feita pelo aparelho Micro Gloss. Após a obtenção dos dados, foi realizada a análise TwoWay ANOVA, verificou-se que o resultado obtido foi estatisticamente significante para a variável de rugosidade, tanto para os fatores de variação de tempo (p = 0,004), concentração do peróxido de carbamida (p = 0,007) e para a interação entre ambos (p = 0,013). Foi feito o teste de múltiplas comparações com ajustes de Bonferroni, para análise dos resultados obtidos. Na análise do brilho, para os resultados encontrados, não houve diferença estatisticamente significante. Assim, pode-se concluir que o peróxido de carbamida 10% não provocou alterações significativas na rugosidade da cerâmica, mas o peróxido de carbamida a 16% provocou aumento da rugosidade após o período de 14 dias de aplicação, com médias em torno de 4,0 μm. Conclui-se, então, que as restaurações cerâmicas devem ser protegidas antes da aplicação de agentes clareadores à base de peróxido de carbamida 10 ou 16%. / The carbamide peroxide gel is used in concentrations ranging from 10 to 35% for periods from 2 to 8 hours daily and its effect on the restorative material isnt yet fully elucidated. The objective of this study was to evaluate the action of carbamide peroxide, 10 and 16%, on the surface roughness and the gloss of a feldspathic dental ceramics. Specimens were prepared (n = 10), IPS d.SIGN ceramics and submitted to carbamide peroxide gel application protocols 10 and 16% at 4 or 3 hours, respectively, at time 14 days. The determination of roughness and gloss was made at baseline, after 07 and after 14 days. The surface roughness was determined by microscope, 3D Measuring Laser Microscope OLS4000 LEXT, OLYMPUS, and the reading of the gloss was taken by Micro Gloss device. After obtaining the data, the TwoWay ANOVA analysis was performed, it was found that the obtained result was statistically significant roughness variable, both for time-variant factor (p = 0.004), concentration of the carbamide peroxide (p = 0.007) and the interaction between both (p = 0.013). It was made for multiple comparisons test with Bonferroni adjustments, for analysis of the results.There was no statistically significant difference in gloss. Thus, it can be concluded that the carbamide peroxide 10% did not cause significant changes in roughness ceramic, but the carbamide peroxide at 16% caused an increased roughness after 14 days of application, averaging around 4, 0 micrometers. Therefore, the ceramic restorations must be protected before the application of bleaching agents based on carbamide peroxide 10 or 16%.
3

Avaliação de diferentes métodos de obtenção do modelo virtual no sistema CAD/CAM CEREC por meio de microtomografia computadorizada

Carneiro, Thiago de Almeida Prado Naves 26 February 2013 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Objectives: The current study evaluated the different methods of virtual model obtention fabricated by CEREC CAD/CAM system, using micro-computed tomography to compare marginal gap on ceramic crowns. Methods: A human premolar (#21) was prepared for an all-ceramic crown. Twenty different digital impressions, designs and crowns were made by the CEREC CAD/CAM system after virtual model obtention by four different methods. The typodont, with the #21 (T), was powdered using a thin layer of titanium dioxide (Sirona) and scanned with the CEREC 3D BlueCam. Regular impressions (RI) were taken of the typodont and were scanned. Master casts (MC) were obtained and scanned. After that, the master casts were powdered (PMC) using a thin layer of titanium dioxide and scanned again. All the crowns were made by feldspathic ceramics (VITABLOCS Mark II) in the InLab milling unit - SIRONA. Each crown was fixed and scanned using a micro-CT to obtain images for marginal gap measurements. The Micro-CT allowed the measurement of marginal gaps at 52 locations in each specimen, totalizing 260 values of vertical misfit and 260 of horizontal misfit. Three calibrated examiners and the mean values were obtained. Results: Considering the percentage of vertical marginal gap up to 75 μm, the results were: T 71.5%, RI 49.2%, MC 69.6% and PMC 71.2%. The percentages of horizontal measurements with overextension of the crowns were: T 8.5%, RI 0%, MC 0.8% and PMC 3.8%, and Conclusion: Based on the results of this study, obtaining virtual models by scanning the mouth or the master cast, with or without powder, showed acceptable values of marginal gap on feldspathic ceramic crowns (VITABLOCS Mark II) manufactured on chairside CEREC CAD/CAM system, considering up to 75μm (our reference value). The higher results of marginal gap for regular impression suggest that is preferable to scan directly the mouth or the master cast. / Objetivos: O presente estudo avaliou diferentes métodos de obtenção do modelo virtual pelo sistema CEREC CAD/CAM, utilizando micro-tomografia computadorizada para comparar a desadaptação marginal em coroas de cerâmica pura obtidas pelo sistema. Métodos: um pré-molar humano (34) foi preparado para uma coroa de cerâmica pura. Impressões digitais, por quatro métodos diferentes foram feitas pelo sistema CEREC CAD / CAM, e as coroas projetadas após obtenção do modelo virtual. Para o grupo Boca (T), o dente humano montado em Typodont foi pulverizado usando uma fina camada de dióxido de titânio (Sirona) e digitalizado com o 3D CEREC BlueCam. Para o grupo Molde (RI), moldagens foram realizadas do Typodont e foram digitalizadas após aplicação de dióxido de titânio. Depois, os modelos de gesso (CM) foram obtidos, a partir destes mesmos moldes, e digitalizados. E por último, os modelos de gesso (PCM) já digitalizados foram submetidos à aplicação de dióxido de titânio e foram digitalizados novamente. Todas as coroas foram feitas por cerâmica feldspática (VITABLOCS Mark II) na unidade de usinagem InLab - Sirona. Cada coroa foi fixada e analisada usando um micro-CT para obter imagens para medições de fenda marginal. O Micro-CT permitiu a medida de desadaptações marginais em 52 locais em cada amostra, totalizando 260 valores de desajuste vertical e 260 de desajuste horizontal. Três examinadores calibrados fizeram as medições e os valores médios foram obtidos. Resultados: Considerando o percentual de fenda marginal vertical de até 75 μm, os resultados foram: 71,5% T, RI 49,2%, 69,6% MC e PMC 71,2%. As porcentagens de medidas horizontais com sobre extensão das coroas foram: T 8,5%, RI 0%, 0,8% e MC PMC 3,8%. Conclusão: Com base nos resultados deste estudo, a obtenção de modelos virtuais, diretamente da boca ou de modelos de gesso, com ou sem aplicação de pó, apresentaram valores aceitáveis de desadaptação marginal em coroas de cerâmica feldspática (VITABLOCS Mark II), fabricadas em consultório pelo sistema CAD / CAM CEREC, considerando 75μm (nosso valor de referência). Os valores mais elevados de desadaptação marginal foram encontrados na digitalização dos moldes e sugerem que é preferível digitalizar diretamente da boca ou de modelos de gesso. / Mestre em Odontologia
4

EFEITO DO CONDICIONAMENTO DE INLAYS CERÂMICAS COM DIFERENTES CONCENTRAÇÕES DE ÁCIDO FLUORÍDRICO NA CARGA DE FRATURA SOB FADIGA DE PRÉ-MOLARES RESTAURADOS / EFFECT OF ETCHING CERAMIC INLAYS WITH DIFFERENT HYDROFLUORIC ACID CONCENTRATION ON THE FATIGUE FAILURE LOAD OF PRE-MOLARS RESTORED

Missau, Taiane Secretti 26 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the effect of different concentrations of hydrofluoric acid on the fatigue failure load of premolars restored with feldspathic ceramic inlays. Sixty upper premolars were embedded in PVC cylinders with acrylic resin up to 2 mm below the cement- enamel junction and prepared using an adapted device for that purpose. Teeth were randomly divided into three groups (n=20): HF1, HF5, and HF10, (conditioning with hydrofluoric acid for 60 s at concentrations of 1%, 5%, and 10%, respectively). Preparations were scanned using the CAD/CAM system with prefabricated blocks of feldspathic ceramic. The internal surfaces of the inlays were treated according to the groups, followed by application of silane coupling agent, and RelyX ARC resin cement was applied for cementation. The fatigue failure load was determined using the staircase method (10 Hz and 105 cycles in each step). The initial load (585.5 N) was applied on the slopes of the cusps through a cylinder attached to the test machine (InstronElectroPuls E3000). The fractured teeth were analyzed under a stereomicroscope for failure analysis. Statistical analysis was performed using one-way ANOVA. There was no statistical difference among the fatigue failure load of the tested groups: HF1 (448.5 N ±79.1), HF5 (360.7 N ±55.4), and HF10 (409.5 N ±121.1). Regarding the fracture mode, there was a predominance of interface fracture (50%), followed by cusp fracture (34.6%). It can be concluded that hydrofluoric acid concentrations used (1%, 5%, and 10%) did not influence the fatigue failure load of feldspathic ceramic inlays cemented on premolars. / Este estudo avaliou o efeito do condicionamento de inlays de cerâmica feldspátic com diferentes concentrações de ácido fluorídrico na carga de fratura sob fadiga de pré-molares. Sessenta pré-molares superiores foram embutidos em cilindros de PVC com resina acrílica, 2 mm abaixo da junção cemento-esmalte e preparados com caixas oclusais (2 mm) e proximais (4mm) padronizadas através de uma máquina adaptada para preparo. Os dentes foram divididos de forma randomizada em três grupos (n = 20): HF1; HF5 e HF10 (condicionamento com ácido fluorídrico durante 60 s nas concentrações de: 1%, 5% e 10% respectivamente). Os dentes foram moldados, os troquéis obtidos escaneados e as restaurações fresadas através do sistema CAD/CAM a partir de blocos pré-fabricados de cerâmica feldspática (VitaBlocks Mark II). A superfície dentária foi tratada com ácido fosfórico (38%) seguida da aplicação do sistema adesivo (Single Bond). A superfície interna das inlays foi condicionada de acordo com os respectivos grupos, seguido da aplicação do agente de união silano. A cimentação das inlays foi realizada com cimento resinoso (RelyX ARC). A carga de falha sob fadiga foi determinada utilizando o método da escada (staircase) a uma freqüência de 10 Hz e 105 ciclos, cuja carga inicial foi de 585,5 N, aplicada somente sobre as vertentes das cúspides, através de um cilindro de 8mm de diâmetro acoplado à máquina de teste (Instron Electropuls E3000). Os dentes fraturados foram analisados sob estereomicroscoscópio para classificação da falha. Análise estatística dos dados foi feita com ANOVA 1-fator. Não houve diferença estatística dos valores médios na carga de fratura sob fadiga entre os grupos testados: HF1-448,5N (±79,09); HF5-360,75 N (±55,4); HF10-409,5 N (±121,1). Considerando o modo de fratura, houve uma predominância de fraturas de interface (50%), seguida de fratura de cúspide (34,6%). Conclui-se que as concentrações de ácido fluorídrico utilizadas (1, 5 e 10%) não influenciam na carga de fratura sob fadiga de inlays de cerâmica feldspática cimentadas em pré molares.

Page generated in 0.0736 seconds