• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do peróxido de carbamida em diferentes concentrações sobre a rugosidade superficial e brilho de uma cerâmica odontológica / The effect of carbamide peroxide in different concentrations on the surface roughness and gloss using dental ceramics

Ana Carolina Cabral Roque 22 January 2016 (has links)
O gel de peróxido de carbamida é utilizado em concentrações que variam de 10 a 35%, por períodos de 2 a 8 horas diárias e seu efeito sobre os materiais restauradores ainda não está totalmente elucidado. Assim, o objetivo desse estudo foi avaliar a ação do peróxido de carbamida, 10 e 16%, sobre a rugosidade superficial e o brilho de uma cerâmica odontológica feldspática. Foram confeccionados espécimes (n=10), com a cerâmica IPS d.SIGN , que foram submetidos a protocolos de aplicação de gel de peróxido de carbamida a 10 e 16%, nos tempos de 4 ou 3 horas diárias respectivamente, pelo período de 14 dias. A determinação da rugosidade e da alteração de brilho foi realizada no início do tratamento, após 07 e após 14 dias. A rugosidade superficial foi determinada pelo microscópio, LEXT 3D Measuring Laser Microscope OLS4000, OLYMPUS, e a leitura do brilho foi feita pelo aparelho Micro Gloss. Após a obtenção dos dados, foi realizada a análise TwoWay ANOVA, verificou-se que o resultado obtido foi estatisticamente significante para a variável de rugosidade, tanto para os fatores de variação de tempo (p = 0,004), concentração do peróxido de carbamida (p = 0,007) e para a interação entre ambos (p = 0,013). Foi feito o teste de múltiplas comparações com ajustes de Bonferroni, para análise dos resultados obtidos. Na análise do brilho, para os resultados encontrados, não houve diferença estatisticamente significante. Assim, pode-se concluir que o peróxido de carbamida 10% não provocou alterações significativas na rugosidade da cerâmica, mas o peróxido de carbamida a 16% provocou aumento da rugosidade após o período de 14 dias de aplicação, com médias em torno de 4,0 μm. Conclui-se, então, que as restaurações cerâmicas devem ser protegidas antes da aplicação de agentes clareadores à base de peróxido de carbamida 10 ou 16%. / The carbamide peroxide gel is used in concentrations ranging from 10 to 35% for periods from 2 to 8 hours daily and its effect on the restorative material isnt yet fully elucidated. The objective of this study was to evaluate the action of carbamide peroxide, 10 and 16%, on the surface roughness and the gloss of a feldspathic dental ceramics. Specimens were prepared (n = 10), IPS d.SIGN ceramics and submitted to carbamide peroxide gel application protocols 10 and 16% at 4 or 3 hours, respectively, at time 14 days. The determination of roughness and gloss was made at baseline, after 07 and after 14 days. The surface roughness was determined by microscope, 3D Measuring Laser Microscope OLS4000 LEXT, OLYMPUS, and the reading of the gloss was taken by Micro Gloss device. After obtaining the data, the TwoWay ANOVA analysis was performed, it was found that the obtained result was statistically significant roughness variable, both for time-variant factor (p = 0.004), concentration of the carbamide peroxide (p = 0.007) and the interaction between both (p = 0.013). It was made for multiple comparisons test with Bonferroni adjustments, for analysis of the results.There was no statistically significant difference in gloss. Thus, it can be concluded that the carbamide peroxide 10% did not cause significant changes in roughness ceramic, but the carbamide peroxide at 16% caused an increased roughness after 14 days of application, averaging around 4, 0 micrometers. Therefore, the ceramic restorations must be protected before the application of bleaching agents based on carbamide peroxide 10 or 16%.
2

Efeito do peróxido de carbamida em diferentes concentrações sobre a rugosidade superficial e brilho de uma cerâmica odontológica / The effect of carbamide peroxide in different concentrations on the surface roughness and gloss using dental ceramics

Roque, Ana Carolina Cabral 22 January 2016 (has links)
O gel de peróxido de carbamida é utilizado em concentrações que variam de 10 a 35%, por períodos de 2 a 8 horas diárias e seu efeito sobre os materiais restauradores ainda não está totalmente elucidado. Assim, o objetivo desse estudo foi avaliar a ação do peróxido de carbamida, 10 e 16%, sobre a rugosidade superficial e o brilho de uma cerâmica odontológica feldspática. Foram confeccionados espécimes (n=10), com a cerâmica IPS d.SIGN , que foram submetidos a protocolos de aplicação de gel de peróxido de carbamida a 10 e 16%, nos tempos de 4 ou 3 horas diárias respectivamente, pelo período de 14 dias. A determinação da rugosidade e da alteração de brilho foi realizada no início do tratamento, após 07 e após 14 dias. A rugosidade superficial foi determinada pelo microscópio, LEXT 3D Measuring Laser Microscope OLS4000, OLYMPUS, e a leitura do brilho foi feita pelo aparelho Micro Gloss. Após a obtenção dos dados, foi realizada a análise TwoWay ANOVA, verificou-se que o resultado obtido foi estatisticamente significante para a variável de rugosidade, tanto para os fatores de variação de tempo (p = 0,004), concentração do peróxido de carbamida (p = 0,007) e para a interação entre ambos (p = 0,013). Foi feito o teste de múltiplas comparações com ajustes de Bonferroni, para análise dos resultados obtidos. Na análise do brilho, para os resultados encontrados, não houve diferença estatisticamente significante. Assim, pode-se concluir que o peróxido de carbamida 10% não provocou alterações significativas na rugosidade da cerâmica, mas o peróxido de carbamida a 16% provocou aumento da rugosidade após o período de 14 dias de aplicação, com médias em torno de 4,0 μm. Conclui-se, então, que as restaurações cerâmicas devem ser protegidas antes da aplicação de agentes clareadores à base de peróxido de carbamida 10 ou 16%. / The carbamide peroxide gel is used in concentrations ranging from 10 to 35% for periods from 2 to 8 hours daily and its effect on the restorative material isnt yet fully elucidated. The objective of this study was to evaluate the action of carbamide peroxide, 10 and 16%, on the surface roughness and the gloss of a feldspathic dental ceramics. Specimens were prepared (n = 10), IPS d.SIGN ceramics and submitted to carbamide peroxide gel application protocols 10 and 16% at 4 or 3 hours, respectively, at time 14 days. The determination of roughness and gloss was made at baseline, after 07 and after 14 days. The surface roughness was determined by microscope, 3D Measuring Laser Microscope OLS4000 LEXT, OLYMPUS, and the reading of the gloss was taken by Micro Gloss device. After obtaining the data, the TwoWay ANOVA analysis was performed, it was found that the obtained result was statistically significant roughness variable, both for time-variant factor (p = 0.004), concentration of the carbamide peroxide (p = 0.007) and the interaction between both (p = 0.013). It was made for multiple comparisons test with Bonferroni adjustments, for analysis of the results.There was no statistically significant difference in gloss. Thus, it can be concluded that the carbamide peroxide 10% did not cause significant changes in roughness ceramic, but the carbamide peroxide at 16% caused an increased roughness after 14 days of application, averaging around 4, 0 micrometers. Therefore, the ceramic restorations must be protected before the application of bleaching agents based on carbamide peroxide 10 or 16%.
3

Avaliação de diferentes métodos de obtenção do modelo virtual no sistema CAD/CAM CEREC por meio de microtomografia computadorizada

Carneiro, Thiago de Almeida Prado Naves 26 February 2013 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Objectives: The current study evaluated the different methods of virtual model obtention fabricated by CEREC CAD/CAM system, using micro-computed tomography to compare marginal gap on ceramic crowns. Methods: A human premolar (#21) was prepared for an all-ceramic crown. Twenty different digital impressions, designs and crowns were made by the CEREC CAD/CAM system after virtual model obtention by four different methods. The typodont, with the #21 (T), was powdered using a thin layer of titanium dioxide (Sirona) and scanned with the CEREC 3D BlueCam. Regular impressions (RI) were taken of the typodont and were scanned. Master casts (MC) were obtained and scanned. After that, the master casts were powdered (PMC) using a thin layer of titanium dioxide and scanned again. All the crowns were made by feldspathic ceramics (VITABLOCS Mark II) in the InLab milling unit - SIRONA. Each crown was fixed and scanned using a micro-CT to obtain images for marginal gap measurements. The Micro-CT allowed the measurement of marginal gaps at 52 locations in each specimen, totalizing 260 values of vertical misfit and 260 of horizontal misfit. Three calibrated examiners and the mean values were obtained. Results: Considering the percentage of vertical marginal gap up to 75 μm, the results were: T 71.5%, RI 49.2%, MC 69.6% and PMC 71.2%. The percentages of horizontal measurements with overextension of the crowns were: T 8.5%, RI 0%, MC 0.8% and PMC 3.8%, and Conclusion: Based on the results of this study, obtaining virtual models by scanning the mouth or the master cast, with or without powder, showed acceptable values of marginal gap on feldspathic ceramic crowns (VITABLOCS Mark II) manufactured on chairside CEREC CAD/CAM system, considering up to 75μm (our reference value). The higher results of marginal gap for regular impression suggest that is preferable to scan directly the mouth or the master cast. / Objetivos: O presente estudo avaliou diferentes métodos de obtenção do modelo virtual pelo sistema CEREC CAD/CAM, utilizando micro-tomografia computadorizada para comparar a desadaptação marginal em coroas de cerâmica pura obtidas pelo sistema. Métodos: um pré-molar humano (34) foi preparado para uma coroa de cerâmica pura. Impressões digitais, por quatro métodos diferentes foram feitas pelo sistema CEREC CAD / CAM, e as coroas projetadas após obtenção do modelo virtual. Para o grupo Boca (T), o dente humano montado em Typodont foi pulverizado usando uma fina camada de dióxido de titânio (Sirona) e digitalizado com o 3D CEREC BlueCam. Para o grupo Molde (RI), moldagens foram realizadas do Typodont e foram digitalizadas após aplicação de dióxido de titânio. Depois, os modelos de gesso (CM) foram obtidos, a partir destes mesmos moldes, e digitalizados. E por último, os modelos de gesso (PCM) já digitalizados foram submetidos à aplicação de dióxido de titânio e foram digitalizados novamente. Todas as coroas foram feitas por cerâmica feldspática (VITABLOCS Mark II) na unidade de usinagem InLab - Sirona. Cada coroa foi fixada e analisada usando um micro-CT para obter imagens para medições de fenda marginal. O Micro-CT permitiu a medida de desadaptações marginais em 52 locais em cada amostra, totalizando 260 valores de desajuste vertical e 260 de desajuste horizontal. Três examinadores calibrados fizeram as medições e os valores médios foram obtidos. Resultados: Considerando o percentual de fenda marginal vertical de até 75 μm, os resultados foram: 71,5% T, RI 49,2%, 69,6% MC e PMC 71,2%. As porcentagens de medidas horizontais com sobre extensão das coroas foram: T 8,5%, RI 0%, 0,8% e MC PMC 3,8%. Conclusão: Com base nos resultados deste estudo, a obtenção de modelos virtuais, diretamente da boca ou de modelos de gesso, com ou sem aplicação de pó, apresentaram valores aceitáveis de desadaptação marginal em coroas de cerâmica feldspática (VITABLOCS Mark II), fabricadas em consultório pelo sistema CAD / CAM CEREC, considerando 75μm (nosso valor de referência). Os valores mais elevados de desadaptação marginal foram encontrados na digitalização dos moldes e sugerem que é preferível digitalizar diretamente da boca ou de modelos de gesso. / Mestre em Odontologia

Page generated in 0.069 seconds