• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 15
  • 15
  • 15
  • 11
  • 9
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia do Comprimento e Geometria de Pinos de Fibra de Vidro no Comportamento Biomecânico de Incisivos Centrais Superiores Tratados Endodonticamente: Uma Análise Pelo Método de Elementos Finitos

MELO, H. A. S. 29 March 2017 (has links)
Made available in DSpace on 2018-08-01T23:26:00Z (GMT). No. of bitstreams: 1 tese_10845_DISSERTAÇÃO versão final para impressão pós- defesa Hosana .pdf: 2851280 bytes, checksum: 8f1119cb040a3a1217c059d48dc16834 (MD5) Previous issue date: 2017-03-29 / A reabilitação de dentes tratados endodonticamente representa um desafio para a odontologia e é alvo de pesquisas que buscam compreender as propriedades físicas, químicas e biomecânicas existentes entre dentes vitais e não vitais e assim indicar o complexo restaurador que seja esteticamente aceitável, com adequada função clínica e longevidade. Para dentes com extensa perda estrutural, os pinos de fibra de vidro têm sido considerados como uma alternativa aos retentores metálicos. O objetivo deste estudo foi avaliar a influência do comprimento e geometria dos pinos de fibra de vidro, sobre o comportamento biomecânico de incisivos centrais superiores tratados endodonticamente, sob uma carga de 100N aplicada a 130° com a superfície palatina, nas seguintes condições: Pinos de Fibra de Vidro (PFV) lisos (L), serrilhado (S), com profundidades de 5mm e 10mm. As diferentes formas de tratamento foram simuladas a partir do modelo computacional tridimensional de um incisivo superior hígido e analisadas qualitativamente através do método de elementos finitos. Os resultados foram avaliados pelo deslocamento dos modelos, critério de falha de von Mises e de tensão máxima principal. Os modelos PFVL5mm, PFVL10mm e PFVS5mm apresentaram um deslocamento na faixa de 0,0458mm a 0,512mm, enquanto que no modelo PFVS10mm, este deslocamento foi de 0,0116. O pino de fibra de vidro liso apresentou uma distribuição de tensões homogênea, enquanto que o pino serrilhado apresentou uma concentração de tensão na interface da geometria serrilhada. O padrão de distribuição nos modelos de pinos de fibra de vidro foi similar ao do dente hígido, porém os modelos restaurados com pinos de comprimentos maiores, resultaram em um gradiente de tensões mais uniforme e com uma maior área de distribuição. Os resultados obtidos indicaram que o pino de fibra de vidro de geometria serrilhado, em maior profundidade, influencia na redução do deslocamento do modelo. Além disso a geometria do pino de fibra de vidro influencia na concentração de tensões ao longo do pino e o aumento da profundidade desses pinos, aumenta a área de distribuição das tensões, de maneira que elas fiquem mais homogêneas.
2

Analise clinica e radiografica de dentes traumatizados submetidos a um protocolo de medicação intracanal com a associação hidroxido de calcio, clorexidina gel 2% e oxido de zinco, sem trocas periodicas / Clinical and radiological analysis of traumatized teeth treated with a intracanal medication protocol combining calcium hydroxide, chlorhexidine 2% gel and zinc oxide with no periodical replacements

Soares, Adriana de Jesus, 1970- 04 October 2007 (has links)
Orientador: Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T18:56:04Z (GMT). No. of bitstreams: 1 Soares_AdrianadeJesus_D.pdf: 9193342 bytes, checksum: 620c39baa06f23f4f4f4edb1ac543e8c (MD5) Previous issue date: 2007 / Resumo: O objetivo do presente estudo foi investigar uma proposta de protocolo terapêutico utilizando a associação do hidróxido de cálcio, clorexidina gel 2% e óxido de zinco (2:1:2) como medicação intracanal, sem substituições periódicas, em dentes traumatizados. Foram examinados 55 dentes unirradiculares, desvitalizados, 15 com ápices incompletos (Grupo I) e 40 com ápices completos (Grupo II), de 33 pacientes de ambos os gêneros, atendidos no Serviço de Atendimento de Traumatismos Dentários da Faculdade de Odontologia de Piracicaba - UNICAMP, Área de Endodontia. No Grupo I, o período médio de permanência da medicação foi de 9,1 meses e no Grupo II, de 8,2. Clinicamente, observaram-se sinais e sintomas presentes antes e depois do período de medicação intracanal, como: presença de mobilidade, fístula, abscesso, dor espontânea e sensibilidade à percussão. A avaliação radiográfica visou identificar a presença de espessamento do ligamento periodontal, lâmina dura, reabsorções inflamatórias e/ou por substituição, áreas de radioluscência apical, além da formação e tipo de barreira periapical. Os dentes do Grupo I foram submetidos a avaliações adicionais para uma análise comparativa dos processos de apicificação dos dentes tratados e de apicigênese de dentes vitais homólogos ou adjacentes aos traumatizados (Grupo Controle). Para tanto, desenvolveu-se o Índice de Convergência Apical (ICAp). Após a análise estatística observou-se que: (1) a ocorrência de sensibilidade à percussão e de presença de mobilidade apresentaram reduções estatisticamente significantes nos Grupos I e II, sendo que os aspectos radiográficos apresentaram, em ambos os grupos, aumento da presença de lâmina dura e redução do espessamento do ligamento periodontal, estatisticamente significantes; (2) o processo de apicificação induzido pelo protocolo de medicação intracanal proposto não diferiu, estatisticamente, da apicigênese de dentes não traumatizados, e (3) ocorreu uma redução estatisticamente significante da radioluscência periapical, nos dentes com formação radicular incompleta. Dessa forma, concluiu-se que o presente protocolo de medicação intracanal pode ser proposto como alternativa para o tratamento de dentes traumatizados desvitalizados, em especial, nos casos com rizogênese incompleta / Abstract: The aim of the present study was to evaluate approaches, the use of an intracanal medication protocol combining calcium hydroxide, chlorhexidine 2% gel and zinc oxide (2:1:2), with no periodical replacements, for the treatment of traumatized teeth. Fifty five single root, non vital teeth were studied. Fifteen had uncompleted apices (Group I), and other forty had complete apices (Group II). All teeth were selected from 33 patients, of both genders, which had been followed by The Center of Dental Traumatisms, of Piracicaba Dental College ? University of Campinas, Endodontics. The mean time of medication permanence was 9.1 and 8.2 months for Group I and II, respectively. Clinical evaluation considered symptoms and signs which were present before and after medication time, such as: dental mobility, fistula, abscess, spontaneous pain and percussion sensibility. Radiological evaluation was performed to verify the presence of cortical alveolar bone, inflammatory and/or replacement resorptions, apical radioluscency areas, and formation and type of periapical barrier. Group I teeth were submitted to aditional evaluations in order to compare its apexification with the apicegenesis process of healthy contralateral or adjacent teeth (Control Group). This was done by means of the development of the Apical Convergence Index (ICap). After statistical approaches, it was showed in the results that: (1) percussion sensibility and dental mobility occurrence showed statistically significant reductions for Group I and II, and concerning radiographic aspects, it was noted that both groups showed statistically significant modifications as the increase of the presence of cortical alveolar bone and the reduction of the periodontal ligament thickness; (2) the apexification process induced by the proposed intracanal medication protocol was not statistically different if compared to the apicegenesis process of healthy contralateral or adjacent teeth, and (3) there was a statistically significant reduction of periapical radiolucency of teeth with uncompleted apices. These findings concluded that the present intracanal medication protocol as an alternative for the treatment of traumatized non vital teeth, mainly those with uncompleted apices / Doutorado / Endodontia / Doutor em Clínica Odontológica
3

Avaliação in vitro da efetividade de associações de agentes clareadores na alteração da cor de dentes manchados por pigmentos sangüineos

Yui, Karen Cristina Kazue [UNESP] 09 June 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-06-09Bitstream added on 2014-06-13T20:01:53Z : No. of bitstreams: 1 yui_kck_dr_sjc.pdf: 2075475 bytes, checksum: 65332c24d92e3b412ae98ae57ab0f400 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar in vitro a efetividade de três associações de materiais clareadores na técnica mediata de clareamento de dentes tratados endodonticamente. Foram utilizados 48 pré-molares humanos íntegros, pigmentados artificialmente com sangue humano. Após preparo biomecânico, os canais radiculares foram obturados e o tampão cervical foi confeccionado com 3mm de cimento de fosfato de zinco ao nível da junção amelo-cementária. Os dentes foram divididos em quatro grupos (n=12): C (controle, sem material clareador), A1 (perborato de sódio + água destilada), A2 (perborato de sódio + peróxido de carbamida a 10%) e A3 (perborato de sódio + peróxido de carbamida a 35%). Os materiais clareadores foram trocados aos sete e 14 dias. Concluiu-se que o perborato de sódio associado ao peróxido de carbamida (tanto a 10%, como a 35%) foi mais efetivo do que quando associado à água destilada. / The aim of this study was to evaluate in vitro the effectiveness of three associations of bleaching agents on artificially stained pulpless teeth. Forty-eight recently extracted intact human premolars were stained by immersing them in human blood, and divided into four groups. All teeth were endodontically treated and 3mm of zinc phosphate cement was placed at the cementoenamel junction. The teeth were divided into one control group and three test groups (n=12): C) control group, without bleaching agent, A1) sodium perborate with water, A2) sodium perborate with 10% carbamide peroxide, A3) sodium perborate with 35% carbamide peroxide. On days 7 and 14, each pulp chamber was refilled with fresh bleaching paste. Color coordinates of CIELAB color system were measured and assessed with the aid of a dental spectrophotometer (EasyShade®, Vita). It was concluded that sodium perborate mixed with carbamide peroxide (10% or 35%) was more effective than mixed with water.
4

Avaliação da resistência à fratura de raízes fragilizadas reabilitadas por diferentes técnicas de construção de núcleos intra-radiculares

Clavijo, Victor Grover Rene [UNESP] 05 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-05Bitstream added on 2014-06-13T19:10:18Z : No. of bitstreams: 1 clavijo_vgr_me_arafo.pdf: 1143518 bytes, checksum: fc7de1c4fc0422cee9413ae0dcdfbad7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A reabilitação de raízes fragilizadas é um procedimento complexo com prognóstico duvidoso. Este estudo, avaliou por meio de compressão, a resistência à fratura e o padrão de fratura de raízes fragilizadas reabilitadas com diferentes técnicas de construção de núcleos intra-radiculares. Quarenta incisivos bovinos hígidos foram divididos em quatro grupos de acordo com a técnica de construção de pinos intra-radiculares: Grupo 1- raízes fragilizadas reabilitadas com núcleo metálico fundido; Grupo 2- raízes fragilizadas reabilitadas com pinos de fibra de vidro e pinos acessórios de fibra de vidro; Grupo 3- raízes fragilizadas reabilitadas com pino anatômico direto (resina composta + pino de fibra de vidro) ; Grupo 4- raízes fragilizadas reabilitadas com pino anatômico indireto de fibra de vidro. Todos os grupos tiveram seus núcleos cimentados com o cimento resinoso Multilink e as porções coronárias padronizadas por uma matriz de resina acrílica. Os corpos de prova forma submetidos à Máquina de Ensaio Universal à uma velocidade de carga de 0,5mm/min até sua fratura numa angulação de 135° em relação ao longo eixo do dente sobre a face palatina. Os valores médios de resistência à fratura foram: Grupo 1- 575,54N; Grupo 2- 400,49N; Grupo 3- 483,39N; Grupo- 4 559,19N. A análise de variância (ANOVA) (p<0,05) a um critério mostrou diferença estatisticamente. O grupo 1 e 4 médias diferentes, porém estatisticamente iguais, mas maiores estaticamente que o grupo 2 e 3. Os percentuais de raízes com prognóstico favorável após a fratura foram: Grupo 1- 0%; Grupo 2- 80%; Grupo 3- 100% ; Grupo 4- 100%. Os pinos anatômicos direto e indireto mostraram ser uma nova opção para reabilitação de raízes fragilizadas. / The rehabilitation of weakened roots is a complex procedure with an unpredictable prognosis. This study evaluated by compression to fracture resistance and the fracture pattern of weakened roots restored with different construction techniques of intra-radicular posts. Forty hygid bovine incisors were divided into four groups according to each technique of construction of the intra-radicular posts: Group 1- weakened roots restored with metallic posts,; Group 2- weakened roots restored with glass fiber posts and accessory glass fiber posts; Group 3- weakened roots restored with direct anatomic posts (composite resin + glass fiber post); Group 4- weakened roots restored with indirect anatomic post (glass fiber post). All the groups were cemented with dual resinous cement (Multilink) and the coronal portions were patterned by an acrylic resin matrix. The specimens were submitted to a Universal Testing Machine at 0,5mm/min speed until its fracture at an angulation of 135° in relation to the long axis of the tooth. The mean values of fracture resistance were: Group 1- 575,54N; Group 2- 400,49N; Group 3- 483,39N; Group 4- 559,19N. The ANOVA values were (p<0,05) to one criteria showed statistic difference. Group 1 and the 4 different means were statistically the same, but statistically more than the ones of groups 2 and 3. The percentage of roots with favorable prognosis after fracture were: Group 1- 0%; Group 2- 80%; Group 3- 100%; Group 4- 100%. The direct and indirect anatomic post of glass fiber showed a new option to rehabilitate weakened roots.
5

Avaliação clínica do uso de pinos de fibra de carbono na restauração de dentes tratados endodonticamente: um estudo retrospectivo

Coppo, Priscilla Pessin 16 April 2010 (has links)
Made available in DSpace on 2018-08-01T23:26:07Z (GMT). No. of bitstreams: 1 tese_4200_Dissertação Priscilla Coppo.pdf: 1792164 bytes, checksum: a5582e0f738e32fbe27c3261e5994d2d (MD5) Previous issue date: 2010-04-16 / Os estudos clínicos de dentes desvitalizados e restaurados com pinos mostram resultados semelhantes no que diz respeito ao percentual de falhas ou insucessos, apesar de tantas variações técnicas, metodológicas e operatórias entre eles. Os insucessos são maiores quando se tratam de elementos dentais coronariamente destruídos ou comprometidos periapicalmente. Com o objetivo de identificar o efeito das variações clínicas que influenciam na longevidade do tratamento e a prevalência de descimentação de pinos, cárie marginal, fraturas radiculares e de lesões periapicais, foi realizada uma análise retrospectiva do desempenho clínico de dentes restaurados com pino de fibra de carbono. Foram avaliados 139 dentes em 75 pacientes, três anos após a data de cimentação dos pinos. Os dentes foram submetidos a tratamentos endodônticos, incluindo preparos dos condutos para pino, e tratamentos restauradores, realizados pelo mesmo endodontista e protesista, respectivamente, segundo protocolos padronizados. Através de exame clínico, radiográfico, fotográfico, laudos endodônticos e informações obtidas de prontuários, os dentes foram classificados de acordo com: grupos dentais, modalidade de tratamento endodôntico recebida, intervalo decorrido entre a última sessão endodôntica e a cimentação do pino, morfologia do pino, quantidade de remanescente dentinário coronário após preparo protético e sistema da coroa protética utilizado. Não foram constatadas descimentações de pinos, fraturas radiculares, ou cáries, e a classificação foi favorável para 99,3% (138 dentes) dos tratamentos endodônticos realizados. De acordo com os parâmetros analisados, os resultados desse estudo revelaram que as variações clínicas identificadas, consideradas desfavoráveis, não foram fatores determinantes para o insucesso, partindo-se do conjunto de procedimentos e materiais utilizados para o tratamento dos dentes desses pacientes. / Clinical studies of devitalized teeth restored with posts show similar outcomes with regard to the percentage of faults or failures, despite many technical variations, methodological and operative between them. The failures are greater when dealing with teeth coronally destroyed or periapically compromised. The aim of this study was identify the effect of clinical variants that influence the longevity of treatment and prevalence of dislodgment of post, marginal caries, root fracture and periapical lesions was performed a retrospective analysis of clinical performance of teeth restored with carbon fiber post. 139 teeth were evaluated in 75 patients, three years after the date of cementing the posts. The teeth were root canal treatments, including preparations of the conduits to posts, and restorative treatments, performed by the same endodontist and prosthetics, respectively, according to standardized protocols. Through clinical, radiographic, photographic, endodontic reports and information obtained from medical records, the teeth were classified according to: tooth groups, type of endodontic treatment received, time span between the last endodontic session and bonded post, morphology of the post, amount of remaining dentin after crown preparation and prosthetic crown system used. There were no dislodgment of post, root fractures, or caries, and the rank was favorably for 99.3% (138 teeth) of endodontic treatment. According to these parameters, the outcomes of this study revealed that the clinical variations identified, that are considered unfavourable, were not determining for the failure, starting from the set of procedures and materials used for dental treatment of these patients.
6

Influência da presença e do tipo de retentor intrarradicular no comportamento em fadiga de incisivos centrais restaurados com coroas totais /

Andrade, Guilherme Schmitt de. January 2019 (has links)
Orientador: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Coorientador: Lilian Costa Anami / Banca: Carlos Eduardo Francci / Banca: Clovis Pagani / Resumo: Este estudo avalia a influência da presença e tipo de pinos e núcleos na sobrevivência à fadiga de incisivos centrais restaurados com coroas totais. As coroas de 69 incisivos bovinos foram cortadas e as raízes tratadas endodonticamente. As raízes foram distribuídas aleatoriamente em três grupos (n = 23): núcleo de resina composta (NRC), núcleo de resina composta retido por pino de fibra de vidro (PFV) e núcleo metálico fundido (NMF). Todos receberam preparo de coroa total com férula de 2 mm, e então, uma coroa de cerâmica reforçada com leucita foi adesivamente cimentada. Três amostras de cada grupo foram testadas para determinação da carga máxima até a falha. As amostras restantes foram carregadas pelo teste acelerado de fadiga stepwise stress até a fratura ou suspensão após o término de 1,5 x 106 ciclos. A carga e o degrau em que cada espécime falhou foram analisadas pela estatística de Kaplan-Meier e Mantel-Cox (Log Rank test), seguidas por comparação múltipla aos pares, com nível de significância de 5%. O modo de falha foi analisado com estéreomicrocópio. Não houve diferença estatística entre os tratamentos quanto à carga (Mantel-Cox Log-Rank test for trend, X2=0,015, df=1, p=0,901), nem para o número de ciclos (Mantel-Cox Log-Rank test for trend, X2 =3,171, df=1, p=0,995). O modo de falha predominante foi a trinca da coroa. Fratura obliqua da raiz só foi observado nos grupos retidos por pinos. Nos incisivos tratados endodonticamente com férula de 2 mm, a presença e o tipo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : This study evaluates the influence of presence and type of post-and-core systems on fatigue survival of non-vital central incisors restored with all-ceramic crowns. The crowns of 69 bovine incisors were cut and endodontically treated. The roots were randomly assigned into three groups (n=23): composite resin build-up (NRC), glass fiber post-retained-composite build-up (PFV) and cast post-and-core (NMF). All specimens received crown preparation with a 2 mm ferrule, and then a leucite-reinforced ceramic crown was adhesively cemented. Three samples from each group were tested for the determination of the maximum load to failure. The remaining samples were loaded by the accelerated fatigue stepwise stress test until fracture or suspension after the end of 1.5 x 106 cycles. The load and the step on which each specimen failed were analyzed by the Kaplan-Meier and Mantel-Cox (Log Rank test) statistics, followed by multiple paired comparisons, with a significance level of 5%. The failure mode was analyzed with stereomicroscope. There was no statistically significant difference between the treatments (Mantel-Cox Log-Rank test for trend, X2=0.015, df=1, p=0.901), nor for the number of cycles (Mantel-Cox Log-Rank test for trend, X2=3.171, df=1, p=0.995). The predominant failure mode was the crown crack. Oblique root fracture was observed only in groups retained by posts. The presence and type of post system did not influence the fatigue survival of the endodontically treated incisors with a 2 mm ferrule. Non-restorable fractures only occurred on teeth restored with posts...(Complete abstract click electronic access below) / Mestre
7

Avaliação clínica do uso de pinos de fibra de carbono na restauração de dentes tratados endodonticamente: um estudo retrospectivo

Coppo, Priscilla Pessin 16 April 2010 (has links)
Made available in DSpace on 2018-08-01T23:26:07Z (GMT). No. of bitstreams: 1 tese_4200_Dissertação Priscilla Coppo.pdf: 1792164 bytes, checksum: a5582e0f738e32fbe27c3261e5994d2d (MD5) Previous issue date: 2010-04-16 / Os estudos clínicos de dentes desvitalizados e restaurados com pinos mostram resultados semelhantes no que diz respeito ao percentual de falhas ou insucessos, apesar de tantas variações técnicas, metodológicas e operatórias entre eles. Os insucessos são maiores quando se tratam de elementos dentais coronariamente destruídos ou comprometidos periapicalmente. Com o objetivo de identificar o efeito das variações clínicas que influenciam na longevidade do tratamento e a prevalência de descimentação de pinos, cárie marginal, fraturas radiculares e de lesões periapicais, foi realizada uma análise retrospectiva do desempenho clínico de dentes restaurados com pino de fibra de carbono. Foram avaliados 139 dentes em 75 pacientes, três anos após a data de cimentação dos pinos. Os dentes foram submetidos a tratamentos endodônticos, incluindo preparos dos condutos para pino, e tratamentos restauradores, realizados pelo mesmo endodontista e protesista, respectivamente, segundo protocolos padronizados. Através de exame clínico, radiográfico, fotográfico, laudos endodônticos e informações obtidas de prontuários, os dentes foram classificados de acordo com: grupos dentais, modalidade de tratamento endodôntico recebida, intervalo decorrido entre a última sessão endodôntica e a cimentação do pino, morfologia do pino, quantidade de remanescente dentinário coronário após preparo protético e sistema da coroa protética utilizado. Não foram constatadas descimentações de pinos, fraturas radiculares, ou cáries, e a classificação foi favorável para 99,3% (138 dentes) dos tratamentos endodônticos realizados. De acordo com os parâmetros analisados, os resultados desse estudo revelaram que as variações clínicas identificadas, consideradas desfavoráveis, não foram fatores determinantes para o insucesso, partindo-se do conjunto de procedimentos e materiais utilizados para o tratamento dos dentes desses pacientes. / Clinical studies of devitalized teeth restored with posts show similar outcomes with regard to the percentage of faults or failures, despite many technical variations, methodological and operative between them. The failures are greater when dealing with teeth coronally destroyed or periapically compromised. The aim of this study was identify the effect of clinical variants that influence the longevity of treatment and prevalence of dislodgment of post, marginal caries, root fracture and periapical lesions was performed a retrospective analysis of clinical performance of teeth restored with carbon fiber post. 139 teeth were evaluated in 75 patients, three years after the date of cementing the posts. The teeth were root canal treatments, including preparations of the conduits to posts, and restorative treatments, performed by the same endodontist and prosthetics, respectively, according to standardized protocols. Through clinical, radiographic, photographic, endodontic reports and information obtained from medical records, the teeth were classified according to: tooth groups, type of endodontic treatment received, time span between the last endodontic session and bonded post, morphology of the post, amount of remaining dentin after crown preparation and prosthetic crown system used. There were no dislodgment of post, root fractures, or caries, and the rank was favorably for 99.3% (138 teeth) of endodontic treatment. According to these parameters, the outcomes of this study revealed that the clinical variations identified, that are considered unfavourable, were not determining for the failure, starting from the set of procedures and materials used for dental treatment of these patients.
8

Influencia da altura do remanescente coronario, do tipo de retenção intra-radicular e do tipo de coroa total na resistencia e modo de fratura de raizes bovinas / Influence of coronal tooth structure, type of intraradicular retention and total crown on fracture strength and mode of failure of bovine roots

Resende, Cristina do Amparo 24 September 2007 (has links)
Orientadores: Luis Roberto Marcondes Martins, Carlos Jose Soares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T14:12:54Z (GMT). No. of bitstreams: 1 Resende_CristinadoAmparo_D.pdf: 3071325 bytes, checksum: 2b04a3fed0292eea5d925854e4ace595 (MD5) Previous issue date: 2007 / Resumo: O objetivo deste estudo foi avaliar a resistência à fratura de raízes bovinas tratadas endodonticamente e restauradas com diferentes retenções intra-radiculares variando-se o tipo de material da coroa total, na presença e ausência do remanescente coronário. Duzentas raízes com dimensões padronizadas foram divididas aleatoriamente em 20 grupos experimentais (n=10) nos seguintes tratamentos: retenções: pino de fibra de vidro (PFV), pino de fibra de vidro reembasado (PFVR), fibra de polietileno (FP), preenchimento do canal com resina composta (RC) e núcleo metálico fundido (NMF); remanescente: ausente ou com 2 mm de altura; coroa total: cerômero ou cerâmica pura. As coroas totais foram cimentadas com cimento resinoso e as raízes foram fixadas em resina poliestirênica, simulando-se o ligamento periodontal com material de moldagem à base de poliéter. As amostras foram submetidas ao carregamento tangencial de compressão, sob um ângulo de 135º a 0,5 mm/min até ocorrer a falha. Os resultados (ANOVA / Tukey a=0,05) demonstraram que houve diferença estatisticamente significante entre os tipos de pinos (p=0,0058), sendo os grupos restaurados com PFVR e RC apresentaram os maiores valores de resistência à fratura, não diferindo estatisticamente dos grupos restaurados com PFV e PF, e os grupos restaurados com núcleos metálicos fundidos apresentaram os menores valores, não diferindo estatisticamente dos grupos restaurados com PFV e PF. Para os tipos de coroa total (p<0,0001), os grupos restaurados com coroas em cerômero apresentaram maiores valores de resistência à fratura em relação aos grupos restaurados com coroas em cerâmica pura. Os grupos restaurados com fitas de fibra de polietileno mais frequentemente apresentaram padrão de fratura favorável, enquanto os restaurados apenas com resina composta apresentaram padrão de fratura desfavorável, seguidos dos núcleos metálicos fundidos. Para os tipos de coroa total, os grupos restaurados com coroas em cerâmica pura mais frequentemente apresentaram padrão de fratura favorável quando comparados aos grupos restaurados com cerômero, sendo que o mesmo ocorreu para os grupos sem remanescente coronário, quando comparados aos grupos com 2 mm de remanescente / Abstract: The objective of this study was to evaluate the fracture strength of bovine roots endodontically treated and restored by different intraradicular retention varying the type of material of the total crown, in presence or absence of the coronal tooth structure. Two hundred roots with standardized dimensions was divided randomly into 20 experimental groups (n=10) in the following treatments: retentions: fiber glass post, (PFV), relined fiber glass post (PFVR), polyethylene fiber ribbon post (FP), filling of root with composite resin (RC) and cast post and core (NMF); coronal remainder: absence or presence of 2 mm of coronal structure height; total crown: ceromer or all ceramic crown. Total crowns were luted with resin cement and the roots were fixed in resin blocks and artificial periodontal ligament was simulated with casting material made of polyether. The specimens were submitted to compressive strength test at 135º and 0,5 mm/min until fracture occurred. The results (ANOVA/Tukey a=0,05) showed that it had statistical significant difference among the types of retentions (p=0,0058), being the groups restored with PFVR and RC showed the higher failure loads, not differing statistically from groups restored by PFV and PF, and the groups restored by cast post and core showed lower failure loads, not differing statistically from groups restored by PFV and PF. For the types of total crown (p< 0.0001), the groups restored by ceromer crowns showed higher failure loads than did groups restored by all ceramic crowns. The groups restored by polyethylene fiber ribbon post more frequently showed favorable failure modes, while the restored ones only by composite resin showed unfavorable failure modes, followed by cast post and core. For the types of total crown, the groups restored by all ceramic crowns more frequently showed favorable failure modes than did groups restored with ceromer crowns, being that the same it occurred for the groups without coronal tooth structure, when compared to the groups with 2 mm of coronal structure height / Doutorado / Dentística / Doutor em Clínica Odontológica
9

Avaliação da resistência à fratura de dentes endodonticamente tratados, reconstituídos com pinos intra-radiculares, quando submetidos à ciclagem dinâmica / Evaluation of the fracture strength of endodontically treated teeth, reconstructed with post and cores, when submitted to the dynamic loading

Fernando Furtado Antunes de Freitas 26 November 2007 (has links)
Neste estudo, foi avaliada a resistência à fratura de dentes que, já tratados endodonticamente, foram reconstruídos proteticamente com uma coroa de liga de NiCr (Verabond II), a qual era apoiada sobre núcleos compostos por diferentes materiais, obtidos por diferentes técnicas, cimentados no remanescente radicular com o ionômero de vidro Rely X Lutting 2, o qual é acrescido de resina composta. Esses núcleos eram do tipo metálico fundido, no grupo NMF; no grupo ANATO, a resina composta Filtek Z250 (3M ESPE, St. Paul-MN, USA) constituía o núcleo, contendo um pino de fibra de vidro (Reforpost Fibra de Vidro RX, Ângelus Indústria de Produtos Odontológicos Ltda.,Londrina-PR); este mesmo tipo de pino era utilizado no grupo PFFV, sendo diretamente cimentado, sem acréscimo de resina; finalmente, no grupo PFM, um pino metálico (no 064, FKG Dentaire S. A., La Chaux-de-Fonds, Swiss) era cimentado da mesma maneira descrita para o grupo anterior. Os remanescentes radiculares eram provenientes de dentes caninos superiores humanos, distribuídos aleatoriamente, compondo assim os quatro grupos, cada um com 10 espécimes: Os espécimes, após 24 horas da cimentação, foram submetidos a esforços cíclicos, em uma Máquina Eletro-Mecânica de Fadiga, aplicados no sentido do longo eixo dental, com carga de 20 N, na freqüência de 2,0 Hz, assim perfazendo um total de 250.000 ciclos. Excetuando-se 2 corpos-de-prova cujos núcleos soltaram-se da raiz, durante a carga cíclica, todos os demais foram submetidos a uma carga de compressão, numa máquina universal de ensaios (Kratos - Dinamômetros Ltda. São Paulo-SP), regulada na velocidade de 0,5 mm/min, com a força aplicada na face palatina da coroa, num ângulo de 45º em relação ao longo eixo dental, até a ocorrência da fratura radicular. Os valores de resistência encontrados foram os seguintes, em ordem decrescente: 47,677 kgf para o grupo NMF, 34,921 kgf para o PFM, 31,354 kgf para o PFFV e, 27,172 kgf para o ANATO. A análise de variância aplicada aos valores originais apontou diferença entre os grupos estudados e um subseqüente teste de Tukey (p<0,05) permitiu verificar semelhanças entre todos eles, com diferença significante apenas entre os grupos NMF e ANATO. / In this study, was evaluated the strength of endodontically treated teeth, had been reconstructed with a crown of NiCr alloy (Verabond II), which was supported by a post and core for different materials, gotten for different techniques, cemented in the root with the glass ionomer Rely X Lutting 2, which is increased of composed resin. These diferents post and cores were of the casting metallic type, in group NMF; in group ANATO, the composed resin Filtek Z250 (3M ESPE, St. Paul-MN, USA) was the core, contend a glass fiber post (Reforpost Fibra de Vidro RX, Ângelus Indústria de Produtos Odontológicos Ltda., Londrina - PR); this exactly type of post was used in group PFFV, being directly cemented, without resin addition on the core; finally, in group PFM, a metallic post (064, FKG Dentaire S. , La Chaux-of-Fonds, Swiss) were cemented in the same way described for the previous group. All the roots were proceeding from maxillary human canines, randomly distributed, thus composing the four groups, each one with 10 specimens: The specimens, after 24 hours of the cimentation, had been submitted the cyclical efforts, in an Electromechanical Machine of Fatigue, applied in the direction of the long dental axle, with load of 20 N, in the frequency of 2 Hz, thus occuring a total of 250.000 cycles. Excepting 2 body-of-test whose post and cores had been freed of the root, during the cyclical load, all excessively had been submitted to a compression load, in a universal machine of assays (Kratos - Ltda. Dinamômetros. São Paulo - SP), regulated in the speed of 0,5 mm/min, with the force applied in the lingual face of the crown, in an angle of 45º in relation to the long dental axle, until the occurrence of the any root fracture. The joined values of resistance had been following, orderly the decreasing one: 47,677 kgf for group NMF, 34.921 kgf for the PFM, 31,354 kgf for the PFFV and, 27,172 kgf for the ANATO. The analysis of variance applied to the original values pointed difference between the studied groups and a subsequent Tukey test (p<0,05) it allowed to verify similarities between all they, with significant difference only between groups NMF and ANATO.
10

DISTRIBUIÇÃO DE TENSÕES EM MOLAR RESTAURADO PELA TÉCNICA ENDOCROWN / Stress distribution in molar restored Endocrown technique

Molina, Andrés Felipe Cartagena 29 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:20Z (GMT). No. of bitstreams: 1 Andres Felipe Cartagena Molina.pdf: 3076315 bytes, checksum: 06060dc51df633a32dd15312c25f51cd (MD5) Previous issue date: 2012-02-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Endodontically treated molars generally present reduced crown structure, with a greater risk of biomechanical failure when compared with living teeth, restoration technique thereof being a challenge for dental profession. The aim of this paper was to analyze, using the finite elements method (FEM), the stresses distribution in a first molar restored with the Endocrown technique, after simulating functional forces. A lithium disilicate ceramic (IPSe.max Press) and a second generation indirect resin composite (SR Adoro) were used as restorative materials, adhesively cemented to the tooth with a dual polymerization luting agent (Variolink II). In order to obtain their mechanical properties, specimens of these materials were subjected to compressive and diametral tensile strength tests 24 h after manipulation. Based on a CAT scan of the lower third of the face, a 3D model of tooth 36 endodontically treated was simulated. Tooth was sectioned nearly 1 mm above the enamel margin, inner angles were rounded, a layer of 0.05 mm of luting agent was manufactured and the remnant of the original tooth was modeled with both restorative materials. The following models were obtained: Model 1, Endocrown in SR Adoro under axial load; Model 2, Endocrown in IPSe.max Press under axial load; Model 3, Endocrown in SR Adoro under oblique load; Model 4, Endocrown in IPS e.max Press under oblique load. Each model was subjected to a force of 100 N. The strength of the luting and restorative materials and of tooth tissues was evaluated using the Mohr Coulomb (MC) failure criterion, and tensile and compressive contact stresses and shear stresses at the adhesive interface were analyzed. As a result of simulations, according to the MC criterion, Model 2 proved to be 17% better than Model 1, and Models 3 and 4 showed failures in the restorative material. In the adhesive cement and enamel, both for axial and oblique loads, it was found that distribution of stresses was more homogeneous for models with more rigid restorative material, behavior which is repeated in the analysis of tensile and compressive contact stresses and shear stresses. Based on the results obtained, it was possible to conclude that Endocrown restorations, when perfectly cemented and made of ceramic are more resistant to fracture than composite Endocrown. Loads of the oblique direction represent a critical point in the success of the restoration, integrity of the margin and conservation of the tooth remaining. / Dentes tratados endodonticamente apresentam geralmente reduzida estrutura coronária e grande risco de falha biomecânica, quando comparados com dentes vitalizados, sendo, portanto, sua técnica restauradora um desafio para a Odontologia. O objetivo do presente estudo foi analisar, usando o método de elementos finitos (MEF), a distribuição de tensões em um primeiro molar restaurado com a técnica Endocrown, após a simulação de cargas oclusais funcionais. Uma cerâmica à base de dissilicato de lítio (IPSe.max Press) e uma resina composta laboratorial de segunda geração (SR Adoro) foram selecionadas como materiais restauradores, cimentados adesivamente ao dente por uma camada cimento de polimerização dual (Variolink II). Com o objetivo de obter suas propriedades mecânicas, corpos de prova dos materiais cimentante e restaurador foram submetidos a testes de resistência a compressão e tração diametral 24 h após sua manipulação. Utilizando-se uma tomografia do terço inferior da face, um modelo 3D do dente 36 com tratamento endodôntico foi obtido. O dente foi seccionado aproximadamente 1 mm acima do limite amelocementário, os ângulos internos do preparo foram arredondados, uma película de 0,05 mm de cimento foi construída e o restante do dente foi modelado com ambos os materiais restauradores. Foram obtidos os seguintes modelos: Modelo 1, Endocrown confeccionada em SR Adoro submetida a carga axial; Modelo 2, Endocrown confeccionada em IPSe.max Press submetida a carga axial; Modelo 3, Endocrown confeccionada em SR Adoro submetida a carga oblíqua; Modelo 4, Endocrown confeccionada em IPSe.max Press submetida a carga oblíqua. Cada modelo foi submetido a carga de 100 N. A resistência dos materiais cimentante e restauradores e também dos tecidos dentais foi avaliada segundo o critério de falha de Mohr Coulomb (MC), e as tensões de tração e de compressão de contato e as de cisalhamento na interface adesiva foram calculadas. De acordo com os resultados das simulações, segundo o critério de MC, o Modelo 2 demonstrou ser 17% superior ao 1, e os Modelos 3 e 4 demonstraram falha do material restaurador. A distribuição de tensões no cimento e no esmalte dentário, tanto para carga axial quanto para oblíqua, foi mais homogênea nos modelos restaurados com o material mais rígido, comportamento esse que se repetiu na análise de tensões de tração e compressão e de cisalhamento na interface. Concluiu-se que restaurações Endocrowns, se cimentadas adequadamente e confeccionadas em cerâmica, são mais resistentes à fratura do que as de resina laboratorial. As cargas oblíquas representam um ponto crítico para o sucesso da restauração, da sua integridade marginal e da conservação do remanescente dental.

Page generated in 0.1003 seconds