• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 1
  • Tagged with
  • 43
  • 43
  • 16
  • 16
  • 15
  • 15
  • 13
  • 10
  • 8
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influ?ncia do acabamento de preparos para coroas totais com microsc?pio operat?rio na adapta??o marginal de restaura??es em cer?mica tipo CAD-CAM

Oliveira, Jos? Pedro Peixoto de 16 January 2008 (has links)
Made available in DSpace on 2015-04-14T13:29:16Z (GMT). No. of bitstreams: 1 399743.pdf: 674310 bytes, checksum: 694cbc44bc682f21bed71e69a6f99e90 (MD5) Previous issue date: 2008-01-16 / Este estudo teve o objetivo de avaliar a adapta??o de infra-estruturas de cer?mica Lava (3M/ESPE) com tr?s diferentes tipos de acabamento em preparos para coroa total. Trinta pr?-molares humanos, extra?dos por raz?es terap?uticas, foram fixados em blocos de resina acr?lica e divididos aleatoriamente em tr?s grupos (n=10) de acordo com o procedimento para realizar os preparos: grupo 1 - ponta diamantada; Grupo 2 - ponta diamantada e broca multi-laminada; Grupo 3 - ponta diamantada e broca multi-laminada, sendo este ?ltimo instrumento com o uso do microsc?pio operat?rio em aumento de 12,5 vezes. Os preparos foram moldados com silicone por adi??o e os modelos obtidos em gesso especial tipo IV. Os modelos foram enviados para o laborat?rio da 3M/ESPE, o qual confeccionou os casquetes de cer?mica Lava. As infra-estruturas foram cimentadas nos dentes preparados com RelyX Unicem, sendo ent?o inclu?dos em blocos de resina acr?lica e cortados em dois planos: m?sio-distal e vest?bulo-lingual. Desta forma, obteve-se quatro fragmentos, sendo que cada fragmento forneceu duas regi?es para observar a discrep?ncia das margens. Por meio de lupa estereosc?pica, acoplada a uma c?mera de v?deo, foram obtidas imagens digitais da regi?o das margens em aumento de 70 vezes. As medidas de adapta??o marginal foram realizadas no programa Image Tool. De acordo com ANOVA e teste de Tukey (α=0,05), n?o houve diferen?a estat?stica entre os Grupo 1 (88,601 μm) e Grupo 2 (90,946 μm). A menor m?dia foi obtida para o Grupo 3 (58,497 μm), diferindo estatisticamente dos outros dois grupos. P?de-se concluir que o emprego do microsc?pio operat?rio favoreceu a melhor adapta??o marginal nos casquetes de cer?mica Lava.
42

Efeito do tipo de pino, altura do remanescente coronário e carregamento na distribuição de tensões em prótese fixa de três elementos / Effect of post, ferule presence and loading on stress distribution in 3-unit fixed parcial denture

Silva, Gisele Rodrigues da, 1982- 12 July 2012 (has links)
Orientador: Luís Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T16:51:03Z (GMT). No. of bitstreams: 1 Silva_GiseleRodriguesda_D.pdf: 2969310 bytes, checksum: 065fbdffc0e741bd55d3cb562acde2e8 (MD5) Previous issue date: 2012 / Resumo: O objetivo deste estudo foi investigar a influência do retentor intrarradicular, altura do remanescente coronário e tipo de carregamento virtualmente simulado, no comportamento biomecânico de prótese fixa anterior de 3 elementos. Quatro modelos tridimensionais de elementos finitos foram criados comparando-se o tipo de retentor nos dentes pilares (fibra de vidro ou núcleo metálico fundido) e a altura do remanescente coronário (0 e 2 mm). Para simular o tipo de carregamento foram considerados dois níveis de aplicação da força: 1- simulação de contato protrusivo (PRT): 200 N distribuídos nas cristas marginais palatinas dos incisivos superiores, sendo 50 N em cada crista marginal, a 45o do longo eixo do dente e 2- simulação de contato em lateralidade canina (LAT): 200 N aplicados na palatina do canino a 15º. Todos os materiais foram considerados homogêneos, lineares, elásticos e isotrópicos com exceção do pino de fibra de vidro, que foi considerado transversalmente isotrópico. O problema estrutural foi solucionado computacionalmente pelo Método de Elementos Finitos (MEF), em análise estrutural estática. A coerência da simulação foi observada pela análise do deslocamento e pelas tensões de von Mises. O deslocamento foi analisado de forma qualitativa e quantitativa comparando-se a região de deslocamento máximo sofrido pela prótese. Em seguida, foram comparadas as tensões máximas principais ocorridas na região de conexão entre pôntico e dentes pilares, na raiz do incisivo central, do canino e nas interfaces pino-dentina radicular e núcleo de preenchimento-dentina. Concluiu-se que as tensões de tração são concentradas entre pôntico/ pilar e na palatina dos dentes pilares da prótese fixa anterior. Sendo que a protrusão gera maior concentração de tensão máxima principal de tração nos dentes pilares e gera deslocamento duas vezes maior do que a lateralidade. Ademais, a presença de remanescente coronário melhora a distribuição das tensões e o pino de fibra de vidro mostrou-se adequado em prótese fixa anterior de 3 elementos / Abstract: The aim of this study was to investigate the influence of post, load condition and ferule presence in abutment teeth on the stress distribution in the anterior three-unit fixed dental prosthesis (FDP) made of lithium dissilicate. Four three-dimensional finite element (FE) models were created comparing the type of post using on the abutment teeth in two levels (fiberglass post and cast post-and-core) and the coronal remaining in two levels (with or without ferule presence). Two load conditions were applied: 1- 200 N was distributed on palatine marginal ridge of incisive, with 50 N in each ridge, under a 45o angle with the long axis of the tooth, simulating the protrusive contact or 2- 200N was applied on palatine of canine at 15o. All materials were considered homogeneous, linear elastic, and isotropic, with the exception of the glass fiber post, which was considered transversally isotropic. Analysis by Finite Elements Method (FEM), was performed structural analysis. The displacement and Von Mises stress was applied to analyze the coherence o simulation. The displacement was analyzed by quality and quantity resuts in region of maximum prostheses displacement. Maximum principal stress was used as a criterion to compare the study factors. The stress distribution was compared in a descriptive way in the area of the connector, along the interface post/dentin and core/dentin and on abutment dentin teeth. In conclusion, the highest tensile stress was observed in the connector areas and on palatine abutments roots surfaces. The protrusion causes higher stress and displacement than canine guide. The ferrule presence in the abutment teeth reduced the maximum principal tensile stresses on tooth-restoration complex and the fiberglass post seems to improve the stress distribution on anterior 3-unit fixed-dental prostheses / Doutorado / Dentística / Doutora em Clínica Odontológica
43

Fracture load and phase transformation in monolithic zirconia crowns submitted to hydrothermal or mechanical treatments = Carga à fratura e transformação de fase em coroas monolíticas de zircônia submetidas a envelhecimento hidrotérmico ou mecânico / Carga à fratura e transformação de fase em coroas monolíticas de zircônia submetidas a envelhecimento hidrotérmico ou mecânico

Bergamo, Edmara Tatiely Pedroso, 1985- 27 August 2018 (has links)
Orientadores: Wander José da Silva, Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T01:05:41Z (GMT). No. of bitstreams: 1 Bergamo_EdmaraTatielyPedroso_M.pdf: 7968983 bytes, checksum: ebd79c42e62e1085b97f070b982adcce (MD5) Previous issue date: 2015 / Resumo: Os sistemas cerâmicos representam na odontologia uma alternativa aos metais na reabilitação protética, sendo que a zircônia é o material com melhores propriedades mecânicas. Coroas confeccionadas em zircônia sem aplicação de cerâmica de cobertura, chamadas monolíticas, têm se mostrado uma alternativa favorável para reabilitação oral, pois associam alta resistência à fratura e estética satisfatória, assim como evitam a complicação mais evidente em infraestruturas de zircônia que é a fratura da cerâmica de cobertura. A zircônia pura pode assumir 3 formas cristalográficas: monoclínica, tetragonal e cúbica, dependendo da temperatura. A união da zircônia com óxidos estabilizadores, como o óxido de ítrio (Y-TZP) faz com que a zircônia se mantenha na fase tetragonal. No entanto, a zircônia permanece metaestável e mediante relativamente baixas temperaturas, umidade e estresse uma progressiva transformação de fase de tetragonal para monoclínica pode ocorrer e afetar a resistência da mesma. Assim sendo, o presente estudo avaliou a carga à fratura e a transformação de fases da zircônia em coroas monolíticas submetidas ao envelhecimento através de testes térmicos e mecânicos. Setenta coroas monolíticas de zircônia (Y-TZP) foram cimentadas em réplicas de resina composta e separadas aleatoriamente em 5 grupos (n=14): Controle (C), sem tratamento; Envelhecimento hidrotérmico (EH), 122°C, 2 bar de pressão por 1 hora; Fadiga térmica (FT), 104 ciclos, de 5 a 55°C por 30 segundos; Fadiga Mecânica (FM), 106 ciclos, 70 N de carga, deslizamento de 1,5 mm da cúspide mesiopalatina com frequência de 1,4 Hz; e Fadiga Mecânica associada com tratamento térmico (FMT). Ao final de cada tratamento, a carga à fratura foi determinada em máquina de testes universal com célula de carga de 10KN e velocidade de 1mm/min (n=12/grupo). Avaliação de alterações de superfície e o modo e a origem da fratura foram realizadas no microscópio eletrônico de varredura. A transformação de fases foi analisada através da difração de raios X (n=2/grupo). Os dados de resistência à compressão foram analisados por Análise de variância a um fator e o nível de significância foi de 5%. Também foi realizada a distribuição de Weibull. Todas as restaurações sobreviveram aos testes de envelhecimento e não foram observadas diferenças significantes entre os tratamentos para a carga à fratura (p>0,05). O módulo de Weibull variou de 6,2 a 16,6, com diferença significativa para o grupo envelhecido pelo tratamento hidrotérmico. Falhas catastróficas com origem na superfície foram evidenciadas. Na análise da difração de raios X foi observado que houve transformação de fases, para todos os grupos, nas diferentes faces da coroa, variando entre 1,9 a 8,9%. Com base nos dados concluí-se que coroas monolíticas de zircônia evidenciam uma alta carga à fratura, confiabilidade estrutural e apresentaram baixa transformação de fase / Abstract: Nowadays, in dentistry, zirconia ceramic systems represent an alternative to metals in prosthetic treatment due to the excellent mechanical properties. Zirconia crowns made without porcelain veneering, called monolithic, have proven to be a favorable alternative to oral rehabilitation, as they associate high strength and satisfactory aesthetic, while avoiding the most known complications in zirconia prosthesis, chipping and delamination. Pure zirconia can assume three crystallographic forms: monoclinic, tetragonal and cubic depending on the temperature. The zirconia association with stabilizing oxides, such as yttrium oxide (Y-TZP), maintains the zirconia in the tetragonal phase at room temperature. Therefore, zirconia remains metastable and at low temperatures, with moisture and stress a progressive transformation of tetragonal to monoclinic phase can occur and affect its strength. The present study evaluated the fracture load and phase transformation of zirconia monolithic crowns submitted to thermal and mechanical aging tests. Seventy monolithic zirconia crowns (Y-TZP) were cemented in resin-based replica and randomly divided into 5 groups (n = 14): Control (C), no treatment; Hydrothermal aging (HA), 122°C, 2 bar for 1 hour; Thermal Fatigue (TF), 104 cycles between 5 and 55°C for 30 seconds; Mechanical Fatigue (FM) 106 cycles, with a load of 70 N sliding of 1.5 mm in mesiopalatal cusp at 1.4 Hz; Mechanical and Thermal Fatigue associated (MTF). After each treatment, the fracture load was determined in a universal testing machine with 10KN load and speed of 1mm/min (n=12/group). Surface modifications and fracture origin and mode were evaluated by scanning electron microscope. The phase transformation was analyzed by x-ray diffraction (n=2/group). The fracture load data were analyzed by one-way ANOVA at a level of 5%. Also, the Weibull distribution was performed. All restorations survived the aging tests and no significant differences were observed in between treatments (p> 0.05). There was no statistically significant difference in the mean fracture load and characteristic fracture load among the groups (p>.05). The Weibull modulus ranged from 6.2 to 16.6, with significant difference between control and hydrothermal aging groups. Catastrophic failures were observed. Phase transformation was shown at the different surfaces of the crown in all groups (1.8-8.9%). In conclusion, monolithic zirconia crowns showed high fracture load, structural reliability and low phase transformation / Mestrado / Protese Dental / Mestra em Clínica Odontológica

Page generated in 0.1353 seconds