• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do desajuste marginal de coroas totais fundidas em titanio comercialmente puro utilizando diferentes padrões para fundição / Evaluation of marginal misfit of casting commercially pure titanium total crow using differrent pattern for casting

Torres, Jose Walter Murta 09 January 2005 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T02:52:52Z (GMT). No. of bitstreams: 1 Torres_JoseWalterMurta_M.pdf: 1252099 bytes, checksum: 8a9ecb06692b975d77a7808edbe5eeec (MD5) Previous issue date: 2005 / Resumo: Padrões de fundição de restaurações protéticas metálicas são usualmente confeccionados em cera. Todavia, especula-se que possa haver aumento nos valores de desajuste marginal, causado por alterações dimensionais ocorridas quando da remoção dos padrões previamente à inclusão em revestimento. Assim, a resina acrílica quimicamente ativada tornou-se uma opção e seu uso rotineiro em laboratórios comerciais. O titânio possui propriedades como biocompatibilidade, baixa condutividade térmica, baixo custo e alta resistência mecânica, tornando-se o material preferido para implantes e o foco de inúmeros estudos visando seu uso em restaurações e coroas protéticas. Visando o menor desajuste marginal possível é recomendado pelo fabricante do sistema de fundição de titânio o uso de cera para a confecção dos padrões, não havendo avaliações do uso de resina acrílica para este fim. Foi propósito deste estudo comparar o desajuste marginal de coroas unitárias fundidas em titânio comercialmente puro (Ti CP - Tritan; Dentaurum, Alemanha), utilizando-se cera (como controle) e as resinas acrílicas Duralay (Reliance Dental Mfg, Co., EUA) e Pattern Resin (GC America Inc., EUA) na confecção dos padrões. Dez dentes bovinos foram preparados para restaurações tipo coroa total, moldados com silicone e replicados em gesso tipo IV. Dez padrões de fundição com 0,7 mm de espessura foram confeccionados para cada grupo (n=10). As coroas foram fundidas em titânio comercialmente puro em máquina de fundição por plasma e vácuo. Após a fundição, as coroas foram removidas do revestimento e ajustadas nos troquéis e nos dentes correspondentes. Para a leitura dos desajustes marginais foi utilizado um microscópio de medição com precisão de 0,5µm, sendo efetuadas 3 leituras em cada conjunto padrão/dente preparado. Os valores obtidos foram tabulados e submetidos à análise de variância e ao teste de Tukey ao nível de 5% de probabilidade. Foram verificados desajustes de 151µm para as coroas fundidas a partir dos padrões em cera, de 153µm para os padrões obtidos em resina Duralay e de 165µm para as fundições obtidas por padrões em resina Pattern. Não foram verificadas diferenças significativas entre os grupos avaliados, estando estes dentro de valores próximos a 150µm / Abstract: Patterns for casting metallic restorations are usually obtained from wax. However, it is speculated that increased marginal misfits could be created caused by dimensional changes during the removal of the pattern from the cast. Therefore, chemically activated acrylic resin is a routinely option in dental commercial laboratories. The characteristics of titanium include biocompatibility, low thermal conductivity, low cost and high mechanical resistance becoming the material of choice for implants and the focus of innumerous studies in prosthetic field such as crowns. To obtain the lowest marginal misfit in crowns, it is recommended that titanium appliances should be cast using wax as pattern, with no evaluation on the use of acrylic resin for this purpose. The aim of this study was to compare the marginal adjustment of crowns cast in commercially pure titanium (CP Ti - Tritan; Dentaurum, Germany)using wax (control), and the acrylic resins Duralay (Reliance Dental, Mfg Co., USA) and Pattern Resin (GC America Inc., USA) as patterns. Ten bovine teeth were prepared for full crown restorations. Impressions were made in silicone material and replicated in type IV dental stone. Ten 0.7 mm-casting patterns were made for each groups. The crowns were cast in CP Ti in a plasma-vacuum casting machine. After casting, the crowns were removed from the investment and adjusted on the respective preparation. For the marginal misfit readings, a 0.5µm-traveling microscope was used. Three readings were taken from each crown-preparation interface. The means were calculated and submitted to analysis of variance and Tukey test at 5% probability lever. Misfits of 151µm were obtained for the crowns cast using wax as patterns; 153µm when Duralay was used; and, 165µm for the crowns made from Pattern Resin. No significant differences were seen among the groups, and the values about 150µm / Mestrado / Protese Dental / Mestre em Clínica Odontológica
2

Efeito do tipo de pino, altura do remanescente coronário e carregamento na distribuição de tensões em prótese fixa de três elementos / Effect of post, ferule presence and loading on stress distribution in 3-unit fixed parcial denture

Silva, Gisele Rodrigues da, 1982- 12 July 2012 (has links)
Orientador: Luís Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T16:51:03Z (GMT). No. of bitstreams: 1 Silva_GiseleRodriguesda_D.pdf: 2969310 bytes, checksum: 065fbdffc0e741bd55d3cb562acde2e8 (MD5) Previous issue date: 2012 / Resumo: O objetivo deste estudo foi investigar a influência do retentor intrarradicular, altura do remanescente coronário e tipo de carregamento virtualmente simulado, no comportamento biomecânico de prótese fixa anterior de 3 elementos. Quatro modelos tridimensionais de elementos finitos foram criados comparando-se o tipo de retentor nos dentes pilares (fibra de vidro ou núcleo metálico fundido) e a altura do remanescente coronário (0 e 2 mm). Para simular o tipo de carregamento foram considerados dois níveis de aplicação da força: 1- simulação de contato protrusivo (PRT): 200 N distribuídos nas cristas marginais palatinas dos incisivos superiores, sendo 50 N em cada crista marginal, a 45o do longo eixo do dente e 2- simulação de contato em lateralidade canina (LAT): 200 N aplicados na palatina do canino a 15º. Todos os materiais foram considerados homogêneos, lineares, elásticos e isotrópicos com exceção do pino de fibra de vidro, que foi considerado transversalmente isotrópico. O problema estrutural foi solucionado computacionalmente pelo Método de Elementos Finitos (MEF), em análise estrutural estática. A coerência da simulação foi observada pela análise do deslocamento e pelas tensões de von Mises. O deslocamento foi analisado de forma qualitativa e quantitativa comparando-se a região de deslocamento máximo sofrido pela prótese. Em seguida, foram comparadas as tensões máximas principais ocorridas na região de conexão entre pôntico e dentes pilares, na raiz do incisivo central, do canino e nas interfaces pino-dentina radicular e núcleo de preenchimento-dentina. Concluiu-se que as tensões de tração são concentradas entre pôntico/ pilar e na palatina dos dentes pilares da prótese fixa anterior. Sendo que a protrusão gera maior concentração de tensão máxima principal de tração nos dentes pilares e gera deslocamento duas vezes maior do que a lateralidade. Ademais, a presença de remanescente coronário melhora a distribuição das tensões e o pino de fibra de vidro mostrou-se adequado em prótese fixa anterior de 3 elementos / Abstract: The aim of this study was to investigate the influence of post, load condition and ferule presence in abutment teeth on the stress distribution in the anterior three-unit fixed dental prosthesis (FDP) made of lithium dissilicate. Four three-dimensional finite element (FE) models were created comparing the type of post using on the abutment teeth in two levels (fiberglass post and cast post-and-core) and the coronal remaining in two levels (with or without ferule presence). Two load conditions were applied: 1- 200 N was distributed on palatine marginal ridge of incisive, with 50 N in each ridge, under a 45o angle with the long axis of the tooth, simulating the protrusive contact or 2- 200N was applied on palatine of canine at 15o. All materials were considered homogeneous, linear elastic, and isotropic, with the exception of the glass fiber post, which was considered transversally isotropic. Analysis by Finite Elements Method (FEM), was performed structural analysis. The displacement and Von Mises stress was applied to analyze the coherence o simulation. The displacement was analyzed by quality and quantity resuts in region of maximum prostheses displacement. Maximum principal stress was used as a criterion to compare the study factors. The stress distribution was compared in a descriptive way in the area of the connector, along the interface post/dentin and core/dentin and on abutment dentin teeth. In conclusion, the highest tensile stress was observed in the connector areas and on palatine abutments roots surfaces. The protrusion causes higher stress and displacement than canine guide. The ferrule presence in the abutment teeth reduced the maximum principal tensile stresses on tooth-restoration complex and the fiberglass post seems to improve the stress distribution on anterior 3-unit fixed-dental prostheses / Doutorado / Dentística / Doutora em Clínica Odontológica

Page generated in 0.0884 seconds