Return to search

Durabilidade da união resina-dentina : efeito da umidade dentinaria na resistencia da união mediada por primers experimentais / Resin-dentin bonding durability : effect of dentin moisture on bond strength mediated by experimental primers

Orientadores: Mario Fernando de Goes, Marcela Rocha de Oliveira Carrilho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T06:17:38Z (GMT). No. of bitstreams: 1
Almeida_JulioCesarFranco_D.pdf: 499079 bytes, checksum: 777476c1e47008d96a6038604656dce4 (MD5)
Previous issue date: 2009 / Resumo: O objetivo geral deste estudo foi avaliar in vitro os efeitos de variações na umidade dentinária no estabelecimento e durabilidade da união resina-dentina através da associação de materiais e técnicas que apresentam potencial para uso em restaurações adesivas. Para atender ao objetivo geral, dois estudos com objetivos específicos foram propostos: 1) avaliar os efeitos da condição de umidade da dentina na durabilidade da resistência da união (RU) à dentina obtida por meio da associação de oxalato de potássio com primers a base de água ou etanol. 2) avaliar os efeitos da técnica úmida utilizando etanol na durabilidade da RU à dentina obtida através do uso de primers com características
hidrofílicas e hidrofóbicas. Os primers experimentais foram preparados utilizando-se a proporção 35% monômeros / 65% solventes (v/v), como se segue: HEMA/água, HEMA/etanol, Bis-GMA/etanol e um agente de união com características hidrofóbicas (Adper Scothbond Multi-Purpose adhesive, 3M/ESPE) foi usado nos dois estudos. A RU foi avaliada pelo teste de resistência à microtração 24 h após a realização do procedimento adesivo ou após 6 meses de armazenamento em água, utilizando-se dentes humanos hígidos recém extraídos para confecção das amostras de acordo com os objetivos específicos de cada estudo. Os resultados do estudo 1 mostraram que de uma maneira geral a associação de oxalato de potássio com primers a base de água e etanol reduziu significativamente a RU imediata e a longo prazo para os primers a base de água e etanol, independente da condição de umidade da dentina. Os resultados do estudo 2 indicaram que a técnica úmida com etanol resultou em maior RU imediata para os primers com características hidrofílicas e hidrofóbicas enquanto o armazenamento em água por 6 meses diminuiu a RU para o primer hidrofílico, independente da técnica utilizada. / Abstract: The overall goal of this investigation was to evaluate in vitro the effects of dentin moisture variations in the establishment and durability of the resin-dentin bonds by the association of materials and techniques with potential for use in adhesive restorative procedures. In order to meet the overall objective, two studies with specific goals were proposed. 1) to evaluate the effects of dentin moisture condition on the durability of the bond strength (BS) to dentin produced by the association of potassium oxalate with experimental water-and ethanolbased primers; 2) to evaluate the effects of the ethanol wet-bonding technique on the durability of the BS produced with the use of experimental primers with hydrophilic and hydrophobic characteristics. The experimental primers were prepared using the proportion 35% monomers / 65% solvents (v/v) as follows: HEMA/water, HEMA/ethanol, Bis-GMA/ethanol and the same bonding agent with hydrophobic characteristics was used in both studies (Adper Scothbond Multi- Purpose adhesive, 3M/ESPE). A microtensile bond strength test was performed 24 h after bonding procedures and 6 months after water storage, using freshly extracted noncarious human teeth for specimen preparation according to the specific goals of each study. In general, the results of study 1 showed that the association of potassium oxalate with water-and ethanol-based primers reduced significantly the immediate and long-term BS, regardless of the dentin moisture condition. The results of study 2 showed that the ethanol wet-bonding technique resulted in higher immediate BS for the hydrophilic and hydrophobic primers, while 6-month water storage reduced the BS for the hydrophilic primer, regardless of the employed bonding technique. / Doutorado / Doutor em Materiais Dentários

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288202
Date13 August 2018
CreatorsAlmeida, Julio Cesar Franco
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Goes, Mario Fernando de, 1954-, Carrilho, Marcela Rocha de Oliveira, Wang, Linda, Giannini, Marcelo, Pereira, Patricia Nobrega Rodrigues, Souza, João Batista de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Materiais Dentários
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format60 f., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds