Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-02T17:32:40Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_MetodoEspectralLocalizacao.pdf: 36751428 bytes, checksum: 91ff2c96311b8efad399a416dbaad775 (MD5) / Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2017-10-10T17:02:37Z (GMT) / Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-16T14:15:49Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_MetodoEspectralLocalizacao.pdf: 36751428 bytes, checksum: 91ff2c96311b8efad399a416dbaad775 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-11-13T15:52:43Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_MetodoEspectralLocalizacao.pdf: 36751428 bytes, checksum: 91ff2c96311b8efad399a416dbaad775 (MD5) / Made available in DSpace on 2017-11-13T15:52:44Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_MetodoEspectralLocalizacao.pdf: 36751428 bytes, checksum: 91ff2c96311b8efad399a416dbaad775 (MD5)
Previous issue date: 2014-08-18 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, é estabelecida uma metodologia baseada em análise espectral para localização de múltiplas descargas parciais na região dielétrica de bobinas de hidrogeradores. Esta localização de várias descargas objetiva viabilizar diagnóstico preventivo da região isolante da bobina. É concebido um modelo computacional utilizando-se o método das diferenças finitas no domínio do tempo para solucionar numericamente as equações de Maxwell, o qual é validado experimentalmente. O campo elétrico transitório associado a descargas parciais que ocorrem em diferentes posições da bobina é registrado e seu espectro, após processamento e análise estatística, é utilizado para realizar o diagnóstico. Em aproximadamente 90% das simulações realizadas, estimativas precisas da localização das descargas foram obtidas. Um novo método de injeção de sinais de descargas parciais também foi desenvolvido neste trabalho. / A methodology based on spectral analysis is established for performing localization of multiple partial discharges in dielectric region of hydro-generators coils. This pinpointing of multiple discharges aims to provide means for performing preventive diagnosis of the insulating region of the referred coil. A computer model of the structure was conceived by using the finite-difference time-domain method (FDTD-3D) to numerically solve Maxwell’s equations, which is experimentally validated. The transient electric field associated with partial discharges that occur at different positions of the coil is calculated and its spectrum, after processing and statistical analysis, is used to perform the diagnosis. In approximately 90% of simulations, accurate estimates of simultaneous discharges location were obtained. Transient numerical results are in agreement with literatures measurements performed experimentally. A new method of injection of partial discharge signals was also developed in this work.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/9238 |
Date | 18 August 2014 |
Creators | MODESTO, Jonathas Felippe Morais |
Contributors | OLIVEIRA, Rodrigo Melo e Silva de, DMITRIEV, Victor |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0135 seconds