Return to search

Avaliação operacional dos efeitos do perfil de demanda de quatro sistemas de microgeração fotovoltaica conectados à rede / Operational evaluation of the effects of the demand profile of four grid-connected photovoltaic micro-generation systems

Submitted by Luciclea Silva (luci@ufpa.br) on 2018-10-02T16:52:04Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Avaliacaooperacionalefeitos.pdf: 5484311 bytes, checksum: 4583d84683ffeac9822ae43a1e1959f5 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-10-02T16:52:34Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Avaliacaooperacionalefeitos.pdf: 5484311 bytes, checksum: 4583d84683ffeac9822ae43a1e1959f5 (MD5) / Made available in DSpace on 2018-10-02T16:52:34Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_Avaliacaooperacionalefeitos.pdf: 5484311 bytes, checksum: 4583d84683ffeac9822ae43a1e1959f5 (MD5)
Previous issue date: 2018-06-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O tema qualidade de energia elétrica é amplamente pesquisado no meio científico.Diversos fenômenos que afetam a qualidade da energia, e suas consequências, têm sido investigados. Quando se trata de qualidade de energia envolvendo a operação de um sistema fotovoltaico conectado à rede, a preocupação principal é com a operação do inversor, equipamento esse responsável por fazer a interface do gerador fotovoltaico com a rede. A inserção da geração fotovoltaica na rede elétrica requer atenção acerca de certos fatores como a alteração da curva de carga de unidades consumidoras, bem como a elevação nos níveis de tensão, a presença de componentes harmônicas no sinal de corrente da saída do inversor e a variação do fator de potência da unidade consumidora. Este trabalho tem por objetivo realizar testes e avaliar alguns dos aspectos que podem influenciar a qualidade da energia com a inserção de geração fotovoltaica na rede de distribuição, mas também associado com o perfil de demanda do consumidor. Para isso utilizou-se quatro sistemas fotovoltaicos conectados à rede (SFCR), bem como foi montada uma bancada de testes e aquisição de dados para monitorar a operação desses sistemas. Neste trabalho é possível observar que a operação dos SFCR provoca alterações nos níveis de tensão no ponto de acoplamento comum, bem como a interação SFCR e carga causa alterações no perfil de demanda medido pela rede, implicando em uma distorção harmônica total na corrente (THDi) e FP medidos pelo lado da rede, diferentes dos medidos na carga e na saída do inversor. Observou-se que o SFCR pode contribuir tanto para o aumento como para a redução da THDi vista pela rede elétrica local, onde a maior contribuição para distorção harmônica na corrente entregue pela rede está atrelada ao perfil de demanda da carga. / Power quality has been widely researched. Several phenomena that affect power quality, and its consequences, have been investigated. When the power quality theme involves the operation of a grid-connected photovoltaic system, the main concern is about the operation of the inverter, which is responsible for the interface of the photovoltaic generator with the grid. The introduction of photovoltaic generation in the grid requires attention on certain factors such as changes in the load curve, voltage level, harmonic components in the inverter current and variation on the power factor (PF) of the costumer. This work aims to test and evaluate some aspects that may influence the power quality due to the insertion of photovoltaic generation in the grid, associated whit the load demand. Four grid-connected photovoltaic systems were used to develop this work, as well as a data acquisition bench that was set up to monitor the operation of these systems. In this work it is possible to conclude that the operation of photovoltaic systems causes changes in the voltage level at the point of common coupling. Also, the interaction between photovoltaic systems and loads causes changes in the load profile measured by the side of the grid, causing the total harmonic distortion in the current (THDi) and PF measured at this side to be different from those measured at the loads and photovoltaic sides. It is possible to observe that the grid-connected photovoltaic system can contribute to increase or reduce the THDi seen by the local grid, where the greatest contribution of harmonic distortion in the current delivered by the grid is associated to the demand profile of the load.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/10270
Date29 June 2018
CreatorsPARIJÓS JÚNIOR, Ivan Ruy de
ContributorsMACEDO, Wilson Negrão, PEREIRA, Edinaldo José da Silva
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Source1 CD-ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds