• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Emprego de topologia boost semicontrolada para mitigação do conteúdo harmônico de corrente em conversores de 12 pulsos /

Pelicer Junior, João Carlos. January 2019 (has links)
Orientador: Falcondes José Mendes de Seixas / Resumo: Os conversores multipulsos têm sido muito utilizados para a melhoria da qualidade de energia elétrica em sistemas de retificação trifásicos. O principal motivo para tal afirmação é a robustez apresentada por esses conversores, aliada às características intrínsecas da estrutura, que resulta no cancelamento natural de certas componentes de corrente na rede, devido ao defasamento angular provocado pela ação do transformador ou autotransformador utilizado. O que se propõe nesse trabalho é a substituição de cada ponte retificadora a diodos, presente no conversor de 12 pulsos, por uma topologia retificadora trifásica semicontrolada, baseada no conversor boost operando no modo de condução descontínuo (MCD), de modo que, seja possível reduzir de maneira significativa a DHTi (Distorção Harmônica Total de corrente), bem como, incorporar os volumosos transformadores de interfase (IPTs) aos indutores boost de alta frequência, resultando na redução de peso e volume. Foram confeccionadas duas versões do conversor de 12 pulsos com retificadores semicontrolados, uma utilizando transformador isolador e a outra um autotransformador. O que se verificou para ambas as configurações é que a estrutura apresenta um reduzido conteúdo harmônico de corrente se comparado ao conversor tradicional e que, ao se operar no modo de condução descontínuo, faz-se possível o emprego de uma lógica de controle simples, possibilitando assim empregar somente uma malha de tensão, e reduzir significativamente a DHTi do... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Multipulse converters have been widely employed for electrical power quality improvement in three-phase rectifiers systems. The main reason for this statement is the robustness shown by these structures, allied to their natural characteristics, resulting in harmonic canceling at the mains, due to the phase displacement provided by the transformer/autotransformer. In this work, it is proposed the replacement of each rectifier bridge, present in the 12-pulse converter, by a three-phase half-controlled rectifier topology, based on DCM (Discontinuous Conduction Mode) boost converter, thus making it possible to significative reduce the THDi (Total Harmonic Distortion) of the current injected on the mains by the structure. It also incorporates the voluminous IPT's (Interphase Transformer) in the boost high-frequency inductor, resulting in a reduction of weight and size. Two versions of the 12-pulse converter with semicontrolled rectifiers were made, one using an isolating transformer and other using an autotransformer. It was verified that both configurations present a reduced THDi when compared to the traditional converter. So, by electing DCM, it is possible to employ a simpler control logic, employing only one voltage loop and significantly reducing the THDi. / Doutor
2

Avaliação operacional dos efeitos do perfil de demanda de quatro sistemas de microgeração fotovoltaica conectados à rede / Operational evaluation of the effects of the demand profile of four grid-connected photovoltaic micro-generation systems

PARIJÓS JÚNIOR, Ivan Ruy de 29 June 2018 (has links)
Submitted by Luciclea Silva (luci@ufpa.br) on 2018-10-02T16:52:04Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Avaliacaooperacionalefeitos.pdf: 5484311 bytes, checksum: 4583d84683ffeac9822ae43a1e1959f5 (MD5) / Approved for entry into archive by Luciclea Silva (luci@ufpa.br) on 2018-10-02T16:52:34Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Avaliacaooperacionalefeitos.pdf: 5484311 bytes, checksum: 4583d84683ffeac9822ae43a1e1959f5 (MD5) / Made available in DSpace on 2018-10-02T16:52:34Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_Avaliacaooperacionalefeitos.pdf: 5484311 bytes, checksum: 4583d84683ffeac9822ae43a1e1959f5 (MD5) Previous issue date: 2018-06-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O tema qualidade de energia elétrica é amplamente pesquisado no meio científico.Diversos fenômenos que afetam a qualidade da energia, e suas consequências, têm sido investigados. Quando se trata de qualidade de energia envolvendo a operação de um sistema fotovoltaico conectado à rede, a preocupação principal é com a operação do inversor, equipamento esse responsável por fazer a interface do gerador fotovoltaico com a rede. A inserção da geração fotovoltaica na rede elétrica requer atenção acerca de certos fatores como a alteração da curva de carga de unidades consumidoras, bem como a elevação nos níveis de tensão, a presença de componentes harmônicas no sinal de corrente da saída do inversor e a variação do fator de potência da unidade consumidora. Este trabalho tem por objetivo realizar testes e avaliar alguns dos aspectos que podem influenciar a qualidade da energia com a inserção de geração fotovoltaica na rede de distribuição, mas também associado com o perfil de demanda do consumidor. Para isso utilizou-se quatro sistemas fotovoltaicos conectados à rede (SFCR), bem como foi montada uma bancada de testes e aquisição de dados para monitorar a operação desses sistemas. Neste trabalho é possível observar que a operação dos SFCR provoca alterações nos níveis de tensão no ponto de acoplamento comum, bem como a interação SFCR e carga causa alterações no perfil de demanda medido pela rede, implicando em uma distorção harmônica total na corrente (THDi) e FP medidos pelo lado da rede, diferentes dos medidos na carga e na saída do inversor. Observou-se que o SFCR pode contribuir tanto para o aumento como para a redução da THDi vista pela rede elétrica local, onde a maior contribuição para distorção harmônica na corrente entregue pela rede está atrelada ao perfil de demanda da carga. / Power quality has been widely researched. Several phenomena that affect power quality, and its consequences, have been investigated. When the power quality theme involves the operation of a grid-connected photovoltaic system, the main concern is about the operation of the inverter, which is responsible for the interface of the photovoltaic generator with the grid. The introduction of photovoltaic generation in the grid requires attention on certain factors such as changes in the load curve, voltage level, harmonic components in the inverter current and variation on the power factor (PF) of the costumer. This work aims to test and evaluate some aspects that may influence the power quality due to the insertion of photovoltaic generation in the grid, associated whit the load demand. Four grid-connected photovoltaic systems were used to develop this work, as well as a data acquisition bench that was set up to monitor the operation of these systems. In this work it is possible to conclude that the operation of photovoltaic systems causes changes in the voltage level at the point of common coupling. Also, the interaction between photovoltaic systems and loads causes changes in the load profile measured by the side of the grid, causing the total harmonic distortion in the current (THDi) and PF measured at this side to be different from those measured at the loads and photovoltaic sides. It is possible to observe that the grid-connected photovoltaic system can contribute to increase or reduce the THDi seen by the local grid, where the greatest contribution of harmonic distortion in the current delivered by the grid is associated to the demand profile of the load.
3

Avaliação da distorção harmônica total de tensão no ponto de acoplamento comum industrial usando o processo KDD baseado em medição / Evaluation of total voltage harmonic distortion at the industrial joint coupling point using the KDD-based measurement process

OLIVEIRA, Edson Farias de 27 March 2018 (has links)
Submitted by Kelren Mota (kelrenlima@ufpa.br) on 2018-06-13T17:38:37Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AvaliacaoDistorcaoHarmonica.pdf: 4309009 bytes, checksum: 017d26b4d8e0ce6653f66d67f13f4cb6 (MD5) / Approved for entry into archive by Kelren Mota (kelrenlima@ufpa.br) on 2018-06-13T17:39:00Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AvaliacaoDistorcaoHarmonica.pdf: 4309009 bytes, checksum: 017d26b4d8e0ce6653f66d67f13f4cb6 (MD5) / Made available in DSpace on 2018-06-13T17:39:00Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AvaliacaoDistorcaoHarmonica.pdf: 4309009 bytes, checksum: 017d26b4d8e0ce6653f66d67f13f4cb6 (MD5) Previous issue date: 2018-03-27 / In the last decades, the transformation industry has provided the introduction of increasingly faster and more energy efficient products for residential, commercial and industrial use, however these loads due to their non-linearity have contributed significantly to the increase of distortion levels harmonic of voltage as a result of the current according to the Power Quality indicators of the Brazilian electricity distribution system. The constant increase in the levels of distortions, especially at the point of common coupling, has generated in the current day a lot of concern in the concessionaires and in the consumers of electric power, due to the problems that cause like losses of the quality of electric power in the supply and in the installations of the consumers and this has provided several studies on the subject. In order to contribute to the subject, this thesis proposes a procedure based on the Knowledge Discovery in Database - KDD process to identify the impact loads of harmonic distortions of voltage at the common coupling point. The proposed methodology uses computational intelligence and data mining techniques to analyze the data collected by energy quality meters installed in the main loads and the common coupling point of the consumer and consequently establish the correlation between the harmonic currents of the nonlinear loads with the harmonic distortion at the common coupling point. The proposed process consists in analyzing the loads and the layout of the location where the methodology will be applied, in the choice and installation of the QEE meters and in the application of the complete KDD process, including the procedures for collection, selection, cleaning, integration, transformation and reduction, mining, interpretation, and evaluation of data. In order to contribute, the data mining techniques of Decision Tree and Naïve Bayes were applied and several algorithms were tested for the algorithm with the most significant results for this type of analysis as presented in the results. The results obtained evidenced that the KDD process has applicability in the analysis of the Voltage Total Harmonic Distortion at the Point of Common Coupling and leaves as contribution the complete description of each step of this process, and for this it was compared with different indices of data balancing, training and test and different scenarios in different shifts of analysis and presented good performance allowing their application in other types of consumers and energy distribution companies. It also shows, in the chosen application and using different scenarios, that the most impacting load was the seventh current harmonic of the air conditioning units for the collected data set. / Nas últimas décadas, a indústria de transformação, tem proporcionado a introdução de produtos cada vez mais rápidos e energeticamente mais eficientes para utilização residencial, comercial e industrial, no entanto essas cargas devido à sua não linearidade têm contribuído significativamente para o aumento dos níveis de distorção harmônica de tensão em decorrência da corrente conforme indicadores de Qualidade de Energia Elétrica do sistema brasileiro de distribuição de energia elétrico. O constante aumento dos níveis das distorções, principalmente no ponto de acoplamento comum, tem gerado nos dias atuais muita preocupação nas concessionárias e nos consumidores de energia elétrica, devido aos problemas que causam como perdas da qualidade de energia elétrica no fornecimento e nas instalações dos consumidores e isso têm proporcionado diversos estudos sobre o assunto. Com o intuito de contribuir com o assunto, a presente tese propõe um procedimento com base no processo Knowledge Discovery in Database - KDD para identificação das cargas impactantes das distorções harmônicas de tensão no ponto de acoplamento comum. A metodologia proposta utiliza técnicas de Inteligência computacional e mineração de dados para análise dos dados coletados por medidores de qualidade de energia instalados nas cargas principais e no ponto de acoplamento comum do consumidor e consequentemente estabelecer a correlação entre as correntes harmônicas das cargas não lineares com a distorção harmônica no ponto de acoplamento comum. O processo proposto consiste na análise das cargas e do layout do local onde a metodologia será aplicada, na escolha e na instalação dos medidores de QEE e na aplicação do processo KDD completo, incluindo os procedimentos de coleta, seleção, limpeza, integração, transformação e redução, mineração, interpretação, e avaliação dos dados. Com o propósito de contribuição foram aplicadas as técnicas de mineração de dados Árvore de Decisão e Naïve Bayes e foram testados diversos algoritmos em busca do algoritmo com resultados mais significativos para esse tipo de análise conforme apresentado nos resultados. Os resultados obtidos evidenciaram que o processo KDD possui aplicabilidade na análise da Distorção Harmônica Total de Tensão no Ponto de Acoplamento Comum e deixa como contribuição a descrição completa de cada etapa desse processo, e para isso foram comparados com diferentes índices de balanceamento de dados, treinamento e teste e diferentes cenários em diferentes turnos de análise e apresentaram bom desempenho possibilitando sua aplicação em outros tipos de consumidores e empresas de distribuição de energia. Evidencia também, na aplicação escolhida e utilizando diferentes cenários, que a carga mais impactante foi a sétima harmônica de corrente das centrais de ar condicionado para o conjunto de dados coletados.
4

Estudo de técnica utilizando a modulação PWM baseada em portadora aplicada ao inversores monofásicos assimétricos com diodos de grampeamento

Oliveira, Francisco Hércules de 25 May 2017 (has links)
Submitted by Gilvanedja Silva (gilvanedja@biblioteca.ufpb.br) on 2018-03-22T20:42:08Z No. of bitstreams: 1 arquivototal.pdf: 11929036 bytes, checksum: e796f3e04cbf0cf6da3fa9648d4f9270 (MD5) / Made available in DSpace on 2018-03-22T20:42:09Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 11929036 bytes, checksum: e796f3e04cbf0cf6da3fa9648d4f9270 (MD5) Previous issue date: 2017-05-25 / This work presents a technique using carrier-based pulse width modulation (PWM) applied to single-phase asymmetrical multilevel inverters with diodes clamped, aiming to increase the amount of output voltage levels to improve signal quality, reducing the total harmonic distortion rate (THD). The technique was used in inverters of three, four and five levels per arm, providing an output signal with seven, thirteen and nineteen levels respectively, presenting two, six and ten levels higher than the equivalent symmetrical multilevel inverters. The technique was described with a set of equations and procedures that can be generalized for inverters of any number of levels. To verify the operation, simulations were performed using the PSIM program and an experimental assembly of an asymmetrical multilevel inverter of three levels was performed, using a field programmable gate array device (FPGA) in the implementation of the PWM modulator. Finally, the simulation and experimental results that prove the effectiveness of the modulation strategy employed in this work are presented and compared / Este trabalho apresenta uma técnica utilizando a modulação por largura de pulso (PWM) baseada em portadora, aplicada aos inversores multiníveis monofásicos assimétricos com diodos de grampeamento, com o objetivo de elevar a quantidade de níveis na tensão de saída, para melhorar a qualidade do sinal, reduzindo a taxa de distorção harmônica total (THD). A técnica foi empregada em inversores de três, quatro e cinco níveis por braço, fornecendo um sinal de saída com sete, treze e dezenove níveis respectivamente, apresentando dois, seis e dez níveis a mais que os inversores multiníveis simétricos equivalentes. A técnica foi descrita com um conjunto de equações e procedimentos que pode ser generalizada para inversores de qualquer número de níveis. Para comprovar o funcionamento, foram realizadas simulações utilizando o programa PSIM e efetuada montagem experimental de uma inversor multinível assimétrico de três níveis, utilizando na implementação do modulador PWM um dispositivo em matriz de porta programável em campo (FPGA). Por fim, são apresentados e comparados os resultados de simulações e experimentais que comprovam a eficácia da estratégia de modulação empregada neste trabalho

Page generated in 0.1063 seconds