Submitted by Renata Lopes (renatasil82@gmail.com) on 2018-02-28T14:32:12Z
No. of bitstreams: 1
marianeflorianolopessantoslacerda.pdf: 10232685 bytes, checksum: 43a6424d223e0874ce221a2e6565b3ef (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-03-01T15:58:28Z (GMT) No. of bitstreams: 1
marianeflorianolopessantoslacerda.pdf: 10232685 bytes, checksum: 43a6424d223e0874ce221a2e6565b3ef (MD5) / Made available in DSpace on 2018-03-01T15:58:28Z (GMT). No. of bitstreams: 1
marianeflorianolopessantoslacerda.pdf: 10232685 bytes, checksum: 43a6424d223e0874ce221a2e6565b3ef (MD5)
Previous issue date: 2017-03-31 / PROQUALI (UFJF) / Objetivos: O presente estudo se propôs a avaliar a limpeza e modelagem de
canais ovais após preparo com 3 sistemas de instrumentação usando
correlação entre método analíticos.
Materiais e métodos: Raízes distais de molares inferiores com canais ovais e
vitalidade pulpar foram inicialmente escaneadas por microtomografia
computadorizada (micro-CT) para seleção e distribuição das amostras em três
grupos experimentais de acordo com o instrumento a ser avaliado: selfadjusting
files (SAF), TRUShape e XP-endo Shaper. Em todos os grupos,
hipoclorito de sódio a 5,25% aquecido a 37°C foi o irrigante. Após novo
escaneamento em micro-CT, as áreas não tocadas das paredes do canal foram
calculadas e, em seguida, avaliadas histologicamente quanto à quantidade de
remanescente pulpar nos terços radiculares.
Resultados: A 4mm do ápice, SAF apresentou valor significativamente menor
de paredes não tocadas em relação ao XP-endo Shaper (P<0,049). Não foi
possível verificar diferença estatística a 10 mm do ápice (P>0,05). A
quantidade de remanescentes pulpares não apresentou diferença significativa
entre os instrumentos, em nenhum dos terços avaliados. Não houve correlação
significativa entre área não tocada e remanescente pulpar para os instrumentos
testados.
Conclusão: Não houve diferença no percentual de paredes não tocadas entre
os 3 grupos, exceto entre SAF e XP-endo Shaper na avaliação dos 4 mm
apicais. Também não houve diferença significativa na limpeza das paredes não
tocadas. A não correlação entre paredes não tocadas e a quantidade de
remanescentes pulpares indica a eficácia do preparo químico-mecânico com
hipoclorito de sódio como irrigante na eliminação de matéria orgânica sobre as
paredes. / Purpose: The present study evaluated the cleaning and shaping ability of three
instrumentation systems in oval canals of vital teeth using a correlative
analytical approach.
Materials and methods: Distal roots of oval canals with pulp vitality were
scanned by computed microtomography (micro-CT) for sample selection and
distribution into three experimental groups according to the instrument to be
evaluated: self-adjusting files (SAF), TRUShape and XP-endo Shaper. In all
groups, the irrigant was sodium hypochlorite (5.25%) heated at 37°C. After rescanning
by micro-CT, the untouched walls were measured and then
histologically evaluated for the amount of pulp remaining in the root thirds.
Results: SAF was more effective in touching the walls at 4 mm from the apex,
presenting a significantly lower value of untouched walls when compared to XPendo
Shaper (P <0.049). However, it was not possible to verify significant
differences in the full canal length between groups. The amount of pulp
remnants also did not differ between instruments in the canal thirds. There was
no significant correlation between untouched areas and pulp remnants for any
instrument.
Conclusion: There was no significant difference in the amount of untouched
walls between instruments, except between SAF and XP-endo Shaper in the
apical 4 mm. There was no significant difference in the cleaning ability either.
The non-correlation between untouched walls and pulp remnants indicates the
effectiveness of different instruments and sodium hypochlorite irrigation in the
elimination of soft tissue from unprepared walls.
Identifer | oai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/6179 |
Date | 31 March 2017 |
Creators | Lacerda, Mariane Floriano Lopes Santos |
Contributors | Siqueira Júnior, José Freitas, Siqueira, Isabela das Neves Rôças, Marceliano-Alves, Marília, Gonçalves, Lúcio, Campos, Celso Neiva |
Publisher | Universidade Estácio de Sá, -, UERJ, Brasil, - |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Source | reponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0024 seconds