Spelling suggestions: "subject:"instrumentos endodôntico"" "subject:"instrumentos ortodônticos""
1 |
Desinfecção de canais radiculares preparados por diferentes técnicas de instrumentação e regimes de irrigação / Disinfection of root canals prepared by different techniques of instrumentation and irrigation regimesNakamura, Vitor Cesar 23 September 2010 (has links)
O intuito do presente trabalho foi avaliar in vitro a desinfecção de canais radiculares de pré-molares inferiores humanos, variando a técnica de preparo e os regimes de irrigação utilizados. Para isso, 85 espécimes foram padronizados em comprimento e diâmetro apical e, após o devido preparo, receberam contaminação com Enterococcus faecalis e Candida albicans por 28 dias. Os canais foram divididos em 8 grupos: G1 - instrumentação manual associada à irrigação com solução fisiológica; G2 - instrumentação manual associada à irrigação com NaOCl à 1,0%; G3 - instrumentação manual associada à irrigação com NaOCl à 1,0% e AC à 15%; G4 - instrumentação manual associada à irrigação com NaOCl à 5,25%; G5 - instrumentação rotatória associada à irrigação com solução fisiológica; G6 - instrumentação rotatória associada à irrigação com NaOCl à 1,0%; G7 - instrumentação rotatória associada à irrigação com NaOCl à 1,0% e AC à 15%; G8 - instrumentação rotatória associada à irrigação com NaOCl à 5,25%. O grupo controle negativo foi composto por 5 dentes preenchidos com meio de cultura esterilizado. Todos os canais dos grupos experimentais foram preparados até instrumentos com diâmetro final de 0,50mm. Coletas microbianas foram realizada antes e após o PQC, com auxílio de pontas de papel esterilizadas. Raspas de dentina foram coletadas após o PQC com o intuito de verificar a ocorrência de MOs no interior dos túbulos dentinários. Não houve diferença estatística entre as técnicas de instrumentação, quanto à diminuição microbiana no interior dos canais. Quanto aos regimes de irrigação, o soro fisiológico produziu os piores resultados, seguido pelo NaOCl à 1,0%. Já quando acompanhado pelo AC, a desinfecção alcançada não demonstrou diferença estatística quanto aos grupos irrigados com NaOCl à 5,25%. / The purpose of this study was to evaluate the in vitro disinfection achieved in root canals of human mandibular premolars, varying the preparation technique and irrigation regimens. For this, 85 specimens were standardized in length and apical diameter, and after proper preparation were contaminated with Enterococcus faecalis and Candida albicans for 28 days. After this period, the canals were divided into eight experimental groups as follows: G1 - hand instrumentation with irrigation with sterile saline, G2 - hand instrumentation with irrigation with NaOCl to 1.0%, G3 - Manual instrumentation with irrigation with NaOCl to 1.0% and citric acid to 15%, G4 - instrumentation associated with irrigation with NaOCl at 5.25%; G5 - rotary instrumentation associated with irrigation with sterile saline and G6 - rotary instrumentation associated with irrigation with NaOCl to 1.0%; G7 - rotary instrumentation with irrigation with NaOCl to 1.0% and citric acid to 15%; G8 - rotary instrumentation with irrigation with NaOCl at 5.25%. Negative control group was composed of 5 teeth had their canals filled with sterile culture medium. All root canals of the specimens of experimental groups were prepared by instruments with a diameter equivalent to the tip end of 0.50 mm. Microbial samplings were performed before and after the PQC with the aid of sterilized paper points. Dentine chips were collected after the PQC in order to verify the occurrence of microorganisms inside the dentinal tubules. The results showed no statistical difference between the techniques of instrumentation, on the microbial reduction. As for systems of irrigation, saline produced the worst results followed by NaOCl 1.0%. When followed by citric acid, disinfection achieved no difference for the groups irrigated with NaOCl at 5.25%
|
2 |
Influência do diâmetro do forame apical e do calibre do instrumento endodôntico nas leituras odontométricas proporcionadas por dois aparelhos localizadores apicais / Influence of foramen diameter and endodontic instrument size on odontometry reading by two electronic apex locatorsBaldi, Járcio Victório 17 June 2005 (has links)
Este estudo objetivou avaliar a influência do diâmetro do forame e do instrumento endodôntico na leitura odontométrica de dois aparelhos localizadores apicais eletrônicos. Foram utilizados 40 dentes incisivos inferiores, divididos em 4 grupos, de acordo com o diâmetro do forame apical (100, 200, 300 e 400 µm). Após a abertura coronária desses dentes e o acesso aos canais radiculares, realizou-se a medição do comprimento dos mesmos com auxílio de um microscópio clínico com ampliação de 7,8X, da incisal até que a ponta da lima surgisse no forame apical. Os dentes foram colocados em potes individuais contendo solução de ágar a 1% em solução salina de fosfato tamponado, mantendo-se cerca de 2/3 de suas raízes imersas na solução para que pudesse ser feita a leitura com o Root ZX® (J.Morita, Japão) e o NovApex® (Fórum, Israel). Os mesmos foram medidos com limas nº10 até que a distância de 0,5 mm do ápice fosse acusada no display dos aparelhos. Uma outra medida foi realizada nos dentes utilizando-se lima nº10 e limas com diâmetros correspondentes ao diâmetro dos forames (200µm, 300µm e 400µm). Para a análise estatística foi empregado o teste de Análise de Variância a dois critérios para o confronto global entre os aparelhos e o emprego da lima nº10 em todos os dentes e teste de Tukey para as comparações individuais. Os resultados demonstraram diferença estatística na precisão dos dois aparelhos com um resultado mais preciso para o Root ZX® (p<0,05). Dentes com forame, de menor diâmetro, apresentaram uma medida mais precisa com o localizador apical e dentes com forame de maior diâmetro apresentaram uma maior discrepância na medida. O emprego de limas tipo K nº10 nos dentes com forames de diâmetros maiores apresentaram maior precisão na medição quando comparadas às limas coincidentes aos diâmetros dos forames para o aparelho Root ZX®. Para o NovApex® esta correlação só passou a ocorrer a partir da lima nº40. / This study evaluated the influence of foramen diameter and endodontic instrument size on the odontometry reading of two electronic apical measuring devices. Forty mandibular incisors were used, which were divided into four groups according to the apical foramen diameter (100, 200, 300 and 400µm). After coronal opening of these teeth and access to the root canals, the root canal length was measured with aid of a clinical microscope with 7.8x magnification, from the incisal edge until the file tip reached the apical foramen. Ten teeth with 100-µm diameter were placed in individual jars containing 1% agar solution in phosphate-buffered saline, maintaining around 2/3 of their roots immersed in the solution to allow measurement with Root ZX (J. Morita, Japan) and NovApex (Forum, Israel). Teeth were measured with files n. 10 until the distance of 0.5mm from the apex was indicated by the device. Another measurement was performed on the other thirty teeth with files n. 10 and files with diameters corresponding to the foramen diameters (200µm, 300µm and 400µm). Statistical analysis was performed by two-way analysis of variance for overall comparison between the devices and employment of file n. 10 in all teeth, and Tukey test for individual comparisons. The results demonstrated statistical difference in the precision of both devices, with a more accurate result for Root ZX (p<0.05). Teeth with narrower foramina presented a more accurate measurement with the apical measuring device, and teeth with wider foramina presented larger discrepancy in the measurement. Utilization of K file n. 10 in teeth with wider foramina showed more accurate measurements compared to files with size corresponding to the foramen diameters with the Root ZX® device. With the NovApex® device, this correlation was only observed with file n. 40.
|
3 |
Desinfecção de canais radiculares preparados por diferentes técnicas de instrumentação e regimes de irrigação / Disinfection of root canals prepared by different techniques of instrumentation and irrigation regimesVitor Cesar Nakamura 23 September 2010 (has links)
O intuito do presente trabalho foi avaliar in vitro a desinfecção de canais radiculares de pré-molares inferiores humanos, variando a técnica de preparo e os regimes de irrigação utilizados. Para isso, 85 espécimes foram padronizados em comprimento e diâmetro apical e, após o devido preparo, receberam contaminação com Enterococcus faecalis e Candida albicans por 28 dias. Os canais foram divididos em 8 grupos: G1 - instrumentação manual associada à irrigação com solução fisiológica; G2 - instrumentação manual associada à irrigação com NaOCl à 1,0%; G3 - instrumentação manual associada à irrigação com NaOCl à 1,0% e AC à 15%; G4 - instrumentação manual associada à irrigação com NaOCl à 5,25%; G5 - instrumentação rotatória associada à irrigação com solução fisiológica; G6 - instrumentação rotatória associada à irrigação com NaOCl à 1,0%; G7 - instrumentação rotatória associada à irrigação com NaOCl à 1,0% e AC à 15%; G8 - instrumentação rotatória associada à irrigação com NaOCl à 5,25%. O grupo controle negativo foi composto por 5 dentes preenchidos com meio de cultura esterilizado. Todos os canais dos grupos experimentais foram preparados até instrumentos com diâmetro final de 0,50mm. Coletas microbianas foram realizada antes e após o PQC, com auxílio de pontas de papel esterilizadas. Raspas de dentina foram coletadas após o PQC com o intuito de verificar a ocorrência de MOs no interior dos túbulos dentinários. Não houve diferença estatística entre as técnicas de instrumentação, quanto à diminuição microbiana no interior dos canais. Quanto aos regimes de irrigação, o soro fisiológico produziu os piores resultados, seguido pelo NaOCl à 1,0%. Já quando acompanhado pelo AC, a desinfecção alcançada não demonstrou diferença estatística quanto aos grupos irrigados com NaOCl à 5,25%. / The purpose of this study was to evaluate the in vitro disinfection achieved in root canals of human mandibular premolars, varying the preparation technique and irrigation regimens. For this, 85 specimens were standardized in length and apical diameter, and after proper preparation were contaminated with Enterococcus faecalis and Candida albicans for 28 days. After this period, the canals were divided into eight experimental groups as follows: G1 - hand instrumentation with irrigation with sterile saline, G2 - hand instrumentation with irrigation with NaOCl to 1.0%, G3 - Manual instrumentation with irrigation with NaOCl to 1.0% and citric acid to 15%, G4 - instrumentation associated with irrigation with NaOCl at 5.25%; G5 - rotary instrumentation associated with irrigation with sterile saline and G6 - rotary instrumentation associated with irrigation with NaOCl to 1.0%; G7 - rotary instrumentation with irrigation with NaOCl to 1.0% and citric acid to 15%; G8 - rotary instrumentation with irrigation with NaOCl at 5.25%. Negative control group was composed of 5 teeth had their canals filled with sterile culture medium. All root canals of the specimens of experimental groups were prepared by instruments with a diameter equivalent to the tip end of 0.50 mm. Microbial samplings were performed before and after the PQC with the aid of sterilized paper points. Dentine chips were collected after the PQC in order to verify the occurrence of microorganisms inside the dentinal tubules. The results showed no statistical difference between the techniques of instrumentation, on the microbial reduction. As for systems of irrigation, saline produced the worst results followed by NaOCl 1.0%. When followed by citric acid, disinfection achieved no difference for the groups irrigated with NaOCl at 5.25%
|
4 |
Influência do diâmetro do forame apical e do calibre do instrumento endodôntico nas leituras odontométricas proporcionadas por dois aparelhos localizadores apicais / Influence of foramen diameter and endodontic instrument size on odontometry reading by two electronic apex locatorsJárcio Victório Baldi 17 June 2005 (has links)
Este estudo objetivou avaliar a influência do diâmetro do forame e do instrumento endodôntico na leitura odontométrica de dois aparelhos localizadores apicais eletrônicos. Foram utilizados 40 dentes incisivos inferiores, divididos em 4 grupos, de acordo com o diâmetro do forame apical (100, 200, 300 e 400 µm). Após a abertura coronária desses dentes e o acesso aos canais radiculares, realizou-se a medição do comprimento dos mesmos com auxílio de um microscópio clínico com ampliação de 7,8X, da incisal até que a ponta da lima surgisse no forame apical. Os dentes foram colocados em potes individuais contendo solução de ágar a 1% em solução salina de fosfato tamponado, mantendo-se cerca de 2/3 de suas raízes imersas na solução para que pudesse ser feita a leitura com o Root ZX® (J.Morita, Japão) e o NovApex® (Fórum, Israel). Os mesmos foram medidos com limas nº10 até que a distância de 0,5 mm do ápice fosse acusada no display dos aparelhos. Uma outra medida foi realizada nos dentes utilizando-se lima nº10 e limas com diâmetros correspondentes ao diâmetro dos forames (200µm, 300µm e 400µm). Para a análise estatística foi empregado o teste de Análise de Variância a dois critérios para o confronto global entre os aparelhos e o emprego da lima nº10 em todos os dentes e teste de Tukey para as comparações individuais. Os resultados demonstraram diferença estatística na precisão dos dois aparelhos com um resultado mais preciso para o Root ZX® (p<0,05). Dentes com forame, de menor diâmetro, apresentaram uma medida mais precisa com o localizador apical e dentes com forame de maior diâmetro apresentaram uma maior discrepância na medida. O emprego de limas tipo K nº10 nos dentes com forames de diâmetros maiores apresentaram maior precisão na medição quando comparadas às limas coincidentes aos diâmetros dos forames para o aparelho Root ZX®. Para o NovApex® esta correlação só passou a ocorrer a partir da lima nº40. / This study evaluated the influence of foramen diameter and endodontic instrument size on the odontometry reading of two electronic apical measuring devices. Forty mandibular incisors were used, which were divided into four groups according to the apical foramen diameter (100, 200, 300 and 400µm). After coronal opening of these teeth and access to the root canals, the root canal length was measured with aid of a clinical microscope with 7.8x magnification, from the incisal edge until the file tip reached the apical foramen. Ten teeth with 100-µm diameter were placed in individual jars containing 1% agar solution in phosphate-buffered saline, maintaining around 2/3 of their roots immersed in the solution to allow measurement with Root ZX (J. Morita, Japan) and NovApex (Forum, Israel). Teeth were measured with files n. 10 until the distance of 0.5mm from the apex was indicated by the device. Another measurement was performed on the other thirty teeth with files n. 10 and files with diameters corresponding to the foramen diameters (200µm, 300µm and 400µm). Statistical analysis was performed by two-way analysis of variance for overall comparison between the devices and employment of file n. 10 in all teeth, and Tukey test for individual comparisons. The results demonstrated statistical difference in the precision of both devices, with a more accurate result for Root ZX (p<0.05). Teeth with narrower foramina presented a more accurate measurement with the apical measuring device, and teeth with wider foramina presented larger discrepancy in the measurement. Utilization of K file n. 10 in teeth with wider foramina showed more accurate measurements compared to files with size corresponding to the foramen diameters with the Root ZX® device. With the NovApex® device, this correlation was only observed with file n. 40.
|
5 |
Comparação do desgaste da zona de perigo de molares superiores utilizando o sistema rotatório ProTaper e brocas Gates-GliddenCarvalho, Flávio Narciso 30 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-20T19:34:56Z
No. of bitstreams: 1
flavionarcisocarvalho.pdf: 1211132 bytes, checksum: adfc5e1232b5cff137271982964292ec (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T15:25:51Z (GMT) No. of bitstreams: 1
flavionarcisocarvalho.pdf: 1211132 bytes, checksum: adfc5e1232b5cff137271982964292ec (MD5) / Made available in DSpace on 2016-07-13T15:25:51Z (GMT). No. of bitstreams: 1
flavionarcisocarvalho.pdf: 1211132 bytes, checksum: adfc5e1232b5cff137271982964292ec (MD5)
Previous issue date: 2012-03-30 / O objetivo desta pesquisa foi avaliar a espessura dentinária da parede distal das raízes mésio-vestibulares de molares superiores (zona de risco) quando submetida à ação das brocas Gates-Glidden (GG) ou ProTaper, durante processo de instrumentação dos canais radiculares. Para isso foram selecionados 20 molares superiores, que após serem incluídos num bloco de resina de poliéster foram seccionados transversalmente na área entre terço cervical e terço médio (zona de risco). Os espécimes foram fotografados antes e após processo operatório com uma câmera digital Nikon Coolpix 4300 acoplada ao Microscópio Cirúrgico (DF Vasconcelos). Dez amostras tiveram instrumentação realizada nos canais mésio-vestibulares pelas brocas Gates-Glidden (GG) e outras dez nos canais mésio-vestibulares instrumentados pelo sistema rotatório ProTaper. Após a fase de instrumentação os blocos foram novamente fotografados. A menor distância encontrada entre a parede interna do canal e a parede externa referente à zona de risco foi medida, através do programa Image TOOL, antes e após o uso das brocas. Os dados foram tabulados e levados para a análise estatística. Concluiu-se não haver diferença estatisticamente significante no desgaste causado por ambos instrumentos em todos setores analisados. / The aim of this study was to evaluate the thickness of the distal wall ofdentin mesio buccal roots of maxillary molars (risk zone) when subjected to the action of Gates Glidden drills (GG) or ProTaper for process instrumentation of root canals. For this we selected 20 molars, which after being included in a block of polyester resin were sectioned in the area between the cervical third and middle third (risk zone). The specimens were photographed before and after operative process with a Nikon Coolpix 4300 digital camera attached to the surgical microscope (DFVasconcelos). Ten samples were performed in the instrumentationchannels mesiobuccal by Gates Glidden drills (GG) and other ten-university channels mésios instrumented by rotary system ProTaper. After phase instrumentation blocks were photographed again. The shortest distance found between the inner wall of the channel and the outer wall on the risk area was measured using the Image TOOL before and after the use of drills. Data were tabulated and taken for statistical analysis. It was concluded that there was no statistically significant difference in wear caused by both instruments in all sectors analyzed.
|
6 |
Avaliação microtomográfica da modelagem de canais radiculares curvos preparados com sistemas automatizados / Microtomographic evaluation on the modeling of curved root canals prepared with automated systemsVentura, Breno Nappi 29 June 2017 (has links)
O preparo do canal radicular ideal relaciona-se ao processo de sanificação em conjunto com a modelagem que resulta em condições especificas para a obturação dos sistemas de canais radiculares. Com a evolução constante dos sistemas de preparo, a microtomografia computadorizada (micro-CT) se apresenta como método de pesquisa confiável que possibilita uma avaliação completa e detalhada do canal radicular. Para tanto, o objetivo deste estudo foi comparar a capacidade de modelagem do sistema ProTaper Gold (PTG) em relação ao ProTaper Next (PTN) com glide path realizado com lima K #15 ou sistema ProGlider (PG), analisando o transporte da curvatura original do canal, desgaste de dentina, aumento no volume e na superfície do canal radicular e a quantificação das superfícies não tocadas após o preparo do canal radicular em canais mesiais de molares inferiores com curvatura acentuada. A média de curvatura de todos os dentes foi de 54o. Vinte e quatro molares inferiores foram divididos em dois grupos (n=12) de acordo com o glide path realizado (com PG ou com lima K #15). A seguir, o sistema PTG foi utilizado no canal mésio-vestibular e o sistema PTN no canal mésio-lingual, criando mais dois subgrupos. Os dentes foram escaneados por meio da micro-CT antes e após o preparo. Os dados obtidos foram comparados utilizando teste ANOVA para análise de variância de dois fatores e teste Tukey para combinações múltiplas. Nos resultados, em toda extensão do canal radicular, assim como para as análises nos terços cervical, médio e apical, não houve diferença estatisticamente significativa entre os grupos quanto ao transporte do canal. Quanto à quantidade de dentina removida, o sistema PTN combinado com a lima K #15 apresentou porcentagem significativamente menor do que nos outros grupos apenas no terço médio. O percentual de aumento do volume do canal foi maior nos grupos onde o glide path foi realizado com lima K #15 em relação aos grupos com glide path realizado com PG e significativo na totalidade do canal e nas análises individualizadas para os terços cervical e médio. O percentual do aumento da área de superfície foi significativamente maior na análise da totalidade do canal e na análise individualizando o terço médio nos grupos onde o glide path foi realizado com lima K#15. Ocorreu diferença significativa e maior quantidade de paredes não tocadas no terço apical nos grupos onde foi realizado glide path com lima K#15. Diante dos resultados, é possível concluir que em todos os grupos o glide path realizado com lima K #15 ou PG, não apresentou interferência sobre o desvio da curvatura original do canal radicular, no entanto, nos grupos que o PG foi usado, houve maior quantidade de paredes tocadas na região apical. / The ideal root canal preparation is related to the process of cleaning and shaping that results in specific conditions for the filling of root canal systems. Due the constant evolution of preparation systems, microcomputed tomography (micro-CT) has been presented as a reliable method of research that possibilite a complete and detailed appraisal of the root canal. Few studies have been performed on instrumentation systems with this methodology. Therefore, the aim of this study was to compare the shaping ability of the ProTaper Gold (PTG) system and the ProTaper Next (PTN) with glide path done with K #15 file or ProGlider (PG) system, analyzing the canal transportation, quantity of dentine removed, increase in volume and surface of the root canal and the quantification of uninstrumented root canal surface after the its prepare into mesial canals of mandibular molars with severely curvature. Twenty-four mandibular molars were divided in two groups (n=12) according to the glide path accomplished (with PG or with K #15 file). After, the PTG system was used on the mesiobuccal canal and the PTN system on the mesiolingual, creating two more subgroups. The teeth were scanned by a micro-CT before and after the preparation. The obtained data were compared using ANOVA test for the variance analyzes of two factors and Tukey test for multiple combinations. In the results, on all of the root canal extension, as well as to the analysis on the cervical, middle and apical thirds, there was no statistically significant difference between the groups about the canal transportation. In terms of the quantity of dentine removed, the PTN system combined with K #15 file showed significant lower percentage than the other groups just in the middle third. The increase on percentage of the canal volume was bigger in the groups where the glide path was done with K #15 file in relation to the groups with glide path accomplished with PG and significant on the totality of the canal and on the individualized analyzes for the cervical and middle thirds. The percentage of the surface increase was significantly greater on the totality analyzes of the canal and on the one individualizing the middle third on the groups where the glide path was performed with K #15 file. There was meaningful difference and greater amount of walls uninstrumented in the apical third on the groups where glide path with K #15 file was used. In front of the results, is possible to conclude that the glide path, done with K #15 file or PG, didn\'t present interference on the deviation of the root canal original curvature to all groups; however, when PG was used, there was a greater number of walls instrumented on the apical region to both systems tested.
|
7 |
Análise comparativa em microtomografia do preparo dos canais mesiais de molares inferiores por quatro sistemas rotatórios de níquel-titânio / A comparison of four nickel-titanium Rotary system to prepare mesial root canals of mandibular molars. A microcomputed tomography studyVillas Bôas, Marcelo Haas 27 May 2011 (has links)
O objetivo deste estudo foi avaliar por meio da microtomografia computadorizada (micro-CT), a qualidade do preparo dos canais mesiais de molares inferiores, realizado pelos sistemas rotatórios de níquel-titânio (NiTi), ProTaper, Mtwo, BioRaCe e Twisted File. As variáveis testadas foram: habilidade em manter o canal centralizado, extensão e direção dos eventuais transportes, quantidade de dentina removida, espessura mínima de dentina remanescente e variações quanto aos volumes apical e total, antes e após a instrumentação. Sessenta e seis molares inferiores foram escaneados no microtomógrafo (Skyscan 1076) utilizando uma resolução de 18 µm. Após a reconstrução das imagens, quarenta dentes foram selecionados e divididos em quatro grupos de acordo com a similaridade da anatomia interna dos canais radiculares (N=10). Os dentes foram instrumentados com os sistemas rotatórios de NiTi até os instrumentos 25/.06 Mtwo e BioRaCe, 25/.08 Twisted File e F2 ProTaper. Após a instrumentação os dentes foram novamente escaneados e os parâmetros testados foram analisados, comparando os valores obtidos antes e após a instrumentação. Os resultados foram submetidos ao teste estatístico não-paramétrico de Mann Whitney e de Kruskal-Wallis e Dunn. Nos quatro grupos, não houve diferença entre os sistemas rotatórios relativos ao transporte do canal em todos os níveis radiculares. Adicionalmente, o terço cervical apresentou a maior quantidade de transporte quando comparado aos níveis apicais e a menor quantidade de dentina remanescente, especialmente para a zona de perigo em comparação com os demais níveis. A avaliação da variável dentina remanescente demostrou que não houve diminuição da quantidade de dentina em nenhuma das direções avaliadas nos níveis apicais em nenhum dos sistemas rotatórios. Similarmente não houve aumento significativo do volume apical e total em comparação ao volume pré-operatório. Não foram encontradas perfurações ou rasgos, o que indica que todos os sistemas avaliados foram seguros nesse item. Conclui-se que os sistemas rotatórios de NiTi avaliados não aumentaram significativamente os volumes apical e total dos canais radiculares, o maior índice de transporte foi no terço cervical e médio para todos os sistemas avaliados. A quantidade de dentina remanescente diminuiu significativamente nos terços cervical e médio na direção voltada para a furca, em todos os sistemas utilizados. / The aim of this study was to evaluate by microcomputed tomography (micro-CT), the quality of mesial canal preparation achieved by 4 nickel-titanium rotary systems (NiTi), ProTaper Mtwo, BioRaCe and Twisted File. The variables tested were: ability to maintain the center of the canal, the extent and direction of any transport, the amount of dentine removed, the remaining dentin thickness and variations in the apical and total volumes, before and after instrumentation. Sixty-six molars were scanned using a X-ray micro-CT scanner (SkyScan 1076) with a resolution of 18 micrometers, after image reconstruction forty teeth were selected and divided into four groups according to the similarity of the internal anatomy of root canals (N = 10). The root canals were instrumented with NiTi rotary systems Mtwo BioRaCe until the 25/.06 instrument, and to the 25.08 Twisted File and F2 ProTaper instruments. After instrumentation the teeth were again scanned and the tested parameters were analyzed by comparing the values obtained before and after instrumentation. The results were tested using statistical non-parametric Mann Whitney and Kruskal-Wallis and Dunn. The transportation of the root canal was similar using the evaluated Rotary systems at all levels. Additionally, the cervical showed the greatest amount of transport when compared to apical levels and the lowest amount of remaining dentin especially for the danger zone in comparison with other levels. The evaluation of the variable remaining dentin showed that there was no decrease in the amount of dentin in either direction evaluated at the apical levels in any of rotary systems. In addition, there was no significant increase in apical or total volume as compared to preoperative values. There were no perforations found indicating that all systems evaluated were safe in this item. It can be concluded that NiTi rotary systems evaluated did not significantly increase the volumes of the root canal system, the transport was higher in the cervical and middle third for all systems evaluated. The amount of remaining dentin decreased significantly in the cervical and middle thirds in the direction toward the furcation in all the systems used.
|
8 |
Metrologia de instrumentos endodônticos por microscopia eletrônica de varredura e análise digital de imagens: uma proposta metodológica / Endodontic instruments metrology by scanning electron microscopy and digital image analysis: a methodological proposalMarcelo Rolla de Souza 12 February 2008 (has links)
A padronização para a fabricação de instrumentos endodônticos em aço inoxidável contribuiu para o desenvolvimento de novos aspectos geométricos. Surgiram propostas de alterações no desenho da haste helicoidal, da seção reta transversal, da ponta, da conicidade e do diâmetro na extremidade (D0). Concomitantemente, o emprego de ligas em Níquel-Titânio possibilitou a produção de instrumentos acionados a motor, largamente empregados hoje. A cada ano a indústria lança instrumentos com diversas modificações, sem, contudo, disponibilizar informações suficientes quanto às implicações clínicas destas modificações. Existe um crescente interesse no estudo dos diferentes aspectos geométricos e sua precisa metrologia. Tradicionalmente, a aferição de aspectos geométricos de instrumentos endodônticos é realizada visualmente através de microscopia ótica. Entretanto, esse procedimento visual é lento e subjetivo. Este trabalho propõe um novo método para a metrologia de instrumentos endodônticos baseado no microscópio eletrônico de varredura e na análise digital das imagens. A profundidade de campo do MEV permite obter a imagem de todo o relevo do instrumento endodôntico a uma distância de trabalho constante. Além disso, as imagens obtidas pelo detector de elétrons retro-espalhados possuem menos artefatos e sombras, tornando a obtenção e análise das imagens mais fáceis. Adicionalmente a análise das imagens permite formas de mensuração mais eficientes, com maior velocidade e qualidade. Um porta-amostras específico foi adaptado para obtenção das imagens dos instrumentos endodônticos. Ele é composto de um conector elétrico múltiplo com terminais parafusados de 12 pólos com 4 mm de diâmetro, numa base de alumínio coberta por discos de ouro. Os nichos do conector (terminais fêmeas) têm diâmetro apropriado (2,5 mm) para o encaixe dos instrumentos endodônticos. Outrossim, o posicionamento ordenado dos referidos instrumentos no conector elétrico permite a aquisição automatizada das imagens no MEV. Os alvos de ouro produzem, nas imagens de elétrons retro-espalhados, melhor contraste de número atômico entre o fundo em ouro e os instrumentos. No porta-amostras desenvolvido, os discos que compõem o fundo em ouro são na verdade, alvos do aparelho metalizador, comumente encontrados em laboratórios de MEV. Para cada instrumento, imagens de quatro a seis campos adjacentes de 100X de aumento são automaticamente obtidas para cobrir todo o comprimento do instrumento com a magnificação e resolução requeridas (3,12 m/pixel). As imagens obtidas são processadas e analisadas pelos programas Axiovision e KS400. Primeiro elas são dispostas num campo único estendido de cada instrumento por um procedimento de alinhamento semi-automático baseado na inter-relação com o Axiovision. Então a imagem de cada instrumento passa por uma rotina automatizada de análise de imagens no KS400. A rotina segue uma sequência padrão: pré-processamento, segmentação, pós-processamento e mensuração dos aspectos geométricos. / The standardization of stainless steel endodontic instruments has contributed to the development of new geometric features. Many design changes in tip shape, cross section, tapering and diameters have come out. At the same time, the use of Ni-Ti alloys enabled the production of rotary instruments, which are widely employed nowadays. In fact, the industry continuously releases novel instruments with different designs. Nevertheless, not enough information is provided about these modifications and their clinical impacts. Thus, there is a growing interest in the study of these different geometric features and their accurate metrology. Traditionally, the measurement of geometric aspects in endodontic instruments is made visually under an optical microscope. However, this visual procedure is subjective and slow. This work proposes a new method for the metrology of endodontic instruments based on scanning electron microscope (SEM) and digital image analysis. The superior depth of field of the SEM allows the whole relief of an endodontic instrument to be imaged at a constant working distance. Moreover, the images from the back-scattered electrons (BSE) detector have less artifacts and shadows, making the image analysis task easier. In addition, image analysis provides efficient ways of measuring with greater speed and statistical quality. A specific sample holder was adapted for the task of imaging endodontic files. It is composed of a multiple electrical connector, a 12 pole screw terminal strip (4 mm), on an aluminum base covered by gold plates. The holes (female terminals) in the electrical connector have an appropriate diameter (2.5 mm) to fix the endodontic instruments. Besides, the ordered placement of endodontic instruments on the electrical connector allows automating image acquisition in the SEM. The gold plates produce, in BSE images, greater atomic number contrast between the gold background and the instruments. In the built sample holder, the gold plates are in fact gold targets of a sputter coater, because it is a material commonly present in SEM labs. For each file, 4 to 6 adjacent fields at 100X are automatically imaged, to cover its entire length with the required magnification and resolution (3.12 m/pixel). These acquired images are processed and analyzed by AxioVision and KS400 softwares. First, they are assembled in a single extended field image of each instrument by a semi-automated alignment procedure based on cross-correlation in AxioVision. Then, the image of each entire instrument passes through a fully automated image analysis routine in KS400. This routine follows the image analysis standard sequence: pre-processing, segmentation, post-processing and measurement of geometric aspects. The obtained results are consistent with manual measurements but the proposed method is faster. Since assembling 4 to 6 BSE images in an extended field image is the only step that is not fully automated, the proposed method depends much less on the subjectivity of the human operator.
|
9 |
Influência da conicidade no comportamento mecânico de instrumentos de níquel-titânio / Influence of the tapering in the mechanical behavior of instruments of nickel-titaniumMarco Aurélio Rodrigues do Prado 19 February 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho tem como objetivo avaliar a influência da conicidade de instrumentos de níquel-titânio acionados a motor, na flexibilidade; na resistência a fratura por torção à direita e na resistência a fratura por flexão rotativa, analisando ainda por meio de microscopia eletrônica de varredura a superfície de fratura dos instrumentos ocorridas por torção e por flexão rotativa, bem como a configuração das hélices das hastes de corte helicoidais dos instrumentos junto ao ponto de fratura. Foram utilizados sessenta instrumentos fabricados em níquel-titânio acionados a motor da marca K3 (Sybron Dental Specialties-Kerr, México), valores nominais de 25mm de comprimento, e de 0,25mm de diâmetro em Do, nas conicidades de 0,02 0,04 e 0,06mm/mm. Dez instrumentos endodônticos de cada conicidade foram avaliados por meio do ensaio não destrutivo de flexão em cantilever e dez instrumentos endodônticos de cada conicidade foram avaliados por meio dos ensaios destrutivos de torção à direita e de flexão rotativa. Diante das metodologias empregadas, dos resultados obtidos e após a execução dos testes estatísticos: Análise de variância no nível de significância de 5%, e do teste de comparações múltiplas de Student-Newman-Keuls a 5%, podemos concluir que: A flexibilidade dos instrumentos ensaiados diminui com o aumento da conicidade da haste de corte helicoidal. O ângulo máximo de torção dos instrumentos ensaiados por torção diminui com o aumento da conicidade da haste de corte helicoidal. O torque máximo até a fratura dos instrumentos ensaiados por torção aumentou com o aumento da conicidade da haste de corte helicoidal. O número de ciclos para a fratura em flexão rotativa diminui com o aumento da conicidade e com o aumento da resistência em flexão (diminuição da flexibilidade) dos instrumentos endodônticos ensaiados. E quanto à análise por meio do microscópio eletrônico de varredura, independentemente, da conicidade e do tipo de carregamento, (torção ou flexão rotativa) aplicado ao instrumento endodôntico, podemos concluir que as amostras fraturadas apresentaram superfície de fratura com característica dúctil. No ensaio de torção, observou-se a reversão do sentido das hélices das hastes de corte helicoidais junto ao ponto de imobilização dos instrumentos. No ensaio de flexão rotativa não ocorreu reversão do sentido das hélices das hastes de corte helicoidais (deformação plástica visível) dos instrumentos fraturados. / This work has as purpose to evaluate the influence of motor driven nickel-titanium instruments tapering, in the flexibility, resistance to fracture by twisting to the right by rotating flexure, analyzing also by means of scanning electronic microscopy the instruments fracture surface arising by twisting and rotating flexure, as well as the configuration of helices of helical cutting rods of instruments near the fracture point. Sixty instrument made of nickel- -titanium and motor-driven of K3 brand were used (Sybron Dental Specialties-Kerr, Mexico), nominal value of 25mm long, and 0,25mm diameter in Do, in tapering of 0,02 0,04 and 0,06mm/mm. Ten endodontic instruments of each tapering were evaluated by means of the non destructive test of flexure in cantilever and ten endodontic instruments of each tapering were evaluated by means of destructive tests twisting to the right and rotating flexure. After the performance of statistic test,: variance analysis at significance level of 5%, and multiple comparison test from Student-Newman-Keuls to 5%, Taking into consideration the implemented methodology, the applied statistical techniques (e.g. variance analysis at significance level of .05 and multiple comparison test from Student-Newman-Keuls at significance level of .05), and the obtained results, it was demonstrated that the flexibility of the instruments tested decreases as the tapering of the helices of helical cutting rods increases. The maximum twisting angle of the instruments tested by twisting decreases as the tapering of the helices of helical cutting rods increases. The maximum torque up to the fracture of the tested instruments increased as the tapering of the helices of helical cutting rods increased. The number of cycles for the fracture in rotating flexure decreases as the tapering increase and the increase of the resistance in flexure (flexibility decrease) of the tested endodontic instruments increased. The analysis by scanning electronic microscopy revealed that, independently of the tapering and the rotating type (twisting or rotating flexure) applied to the endodontic instrument, the fractured samples presented fractured surface of ductile characteristics. A reversion of the helical cutting rods course was observed on the twisting test near the immobilization point. A reversion of the helical cutting rods course (visible plastic deformation) on the rotating flexure test of the fractured instruments was not observed.
|
10 |
Influência da conicidade no comportamento mecânico de instrumentos de níquel-titânio / Influence of the tapering in the mechanical behavior of instruments of nickel-titaniumMarco Aurélio Rodrigues do Prado 19 February 2008 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho tem como objetivo avaliar a influência da conicidade de instrumentos de níquel-titânio acionados a motor, na flexibilidade; na resistência a fratura por torção à direita e na resistência a fratura por flexão rotativa, analisando ainda por meio de microscopia eletrônica de varredura a superfície de fratura dos instrumentos ocorridas por torção e por flexão rotativa, bem como a configuração das hélices das hastes de corte helicoidais dos instrumentos junto ao ponto de fratura. Foram utilizados sessenta instrumentos fabricados em níquel-titânio acionados a motor da marca K3 (Sybron Dental Specialties-Kerr, México), valores nominais de 25mm de comprimento, e de 0,25mm de diâmetro em Do, nas conicidades de 0,02 0,04 e 0,06mm/mm. Dez instrumentos endodônticos de cada conicidade foram avaliados por meio do ensaio não destrutivo de flexão em cantilever e dez instrumentos endodônticos de cada conicidade foram avaliados por meio dos ensaios destrutivos de torção à direita e de flexão rotativa. Diante das metodologias empregadas, dos resultados obtidos e após a execução dos testes estatísticos: Análise de variância no nível de significância de 5%, e do teste de comparações múltiplas de Student-Newman-Keuls a 5%, podemos concluir que: A flexibilidade dos instrumentos ensaiados diminui com o aumento da conicidade da haste de corte helicoidal. O ângulo máximo de torção dos instrumentos ensaiados por torção diminui com o aumento da conicidade da haste de corte helicoidal. O torque máximo até a fratura dos instrumentos ensaiados por torção aumentou com o aumento da conicidade da haste de corte helicoidal. O número de ciclos para a fratura em flexão rotativa diminui com o aumento da conicidade e com o aumento da resistência em flexão (diminuição da flexibilidade) dos instrumentos endodônticos ensaiados. E quanto à análise por meio do microscópio eletrônico de varredura, independentemente, da conicidade e do tipo de carregamento, (torção ou flexão rotativa) aplicado ao instrumento endodôntico, podemos concluir que as amostras fraturadas apresentaram superfície de fratura com característica dúctil. No ensaio de torção, observou-se a reversão do sentido das hélices das hastes de corte helicoidais junto ao ponto de imobilização dos instrumentos. No ensaio de flexão rotativa não ocorreu reversão do sentido das hélices das hastes de corte helicoidais (deformação plástica visível) dos instrumentos fraturados. / This work has as purpose to evaluate the influence of motor driven nickel-titanium instruments tapering, in the flexibility, resistance to fracture by twisting to the right by rotating flexure, analyzing also by means of scanning electronic microscopy the instruments fracture surface arising by twisting and rotating flexure, as well as the configuration of helices of helical cutting rods of instruments near the fracture point. Sixty instrument made of nickel- -titanium and motor-driven of K3 brand were used (Sybron Dental Specialties-Kerr, Mexico), nominal value of 25mm long, and 0,25mm diameter in Do, in tapering of 0,02 0,04 and 0,06mm/mm. Ten endodontic instruments of each tapering were evaluated by means of the non destructive test of flexure in cantilever and ten endodontic instruments of each tapering were evaluated by means of destructive tests twisting to the right and rotating flexure. After the performance of statistic test,: variance analysis at significance level of 5%, and multiple comparison test from Student-Newman-Keuls to 5%, Taking into consideration the implemented methodology, the applied statistical techniques (e.g. variance analysis at significance level of .05 and multiple comparison test from Student-Newman-Keuls at significance level of .05), and the obtained results, it was demonstrated that the flexibility of the instruments tested decreases as the tapering of the helices of helical cutting rods increases. The maximum twisting angle of the instruments tested by twisting decreases as the tapering of the helices of helical cutting rods increases. The maximum torque up to the fracture of the tested instruments increased as the tapering of the helices of helical cutting rods increased. The number of cycles for the fracture in rotating flexure decreases as the tapering increase and the increase of the resistance in flexure (flexibility decrease) of the tested endodontic instruments increased. The analysis by scanning electronic microscopy revealed that, independently of the tapering and the rotating type (twisting or rotating flexure) applied to the endodontic instrument, the fractured samples presented fractured surface of ductile characteristics. A reversion of the helical cutting rods course was observed on the twisting test near the immobilization point. A reversion of the helical cutting rods course (visible plastic deformation) on the rotating flexure test of the fractured instruments was not observed.
|
Page generated in 0.1395 seconds