• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação radiográfica do preparo apical de canais radiculares instrumentados com limas manuais e sistenas rotatórios

José Vasconcelos de Queiroz, Artur January 2003 (has links)
Made available in DSpace on 2014-06-12T23:00:15Z (GMT). No. of bitstreams: 2 arquivo8509_1.pdf: 624683 bytes, checksum: 3bb183e86aacbaf66ac07943ca0139d3 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / Desde a introdução das primeiras limas confeccionadas em liga de níquel-titânio na endodontia, diversos instrumentos manuais e rotatórios foram integrados ao arsenal endodôntico com a promessa de se realizar uma instrumentação rápida e segura do sistema de canais radiculares. No presente trabalho foram utilizados 50 molares inferiores humanos, com processo de rizogênese completa, obtidos no banco de dentes do Curso de Pós-Graduação em Odontologia do Centro de Ciências da Saúde da Universidade Federal de Pernambuco, com o objetivo de avaliar, através de tomadas radiográficas de dupla exposição, as alterações morfológicas produzidas pelo preparo biomecânico no terço apical dos canais radiculares mésio-vestibulares, tendo como instrumento apical final (IAF), uma lima com diâmetro da ponta (D0) igual a 0,25 milímetros. Para se observar a ocorrência da manutenção da patência original do canal foi realizada sobreposição da imagem radiográfica do instrumento apical inicial (IAI), Lima K 10# e o IAF. Foram utilizadas as limas manuais de aço inoxidável Flexofile® (Dentsply/Maillefer, Ballaigues, Swiss), e Tipo K® (Dyna, Burges, France). As limas de níquel-titânio, Nitiflex® (Dentsply/Maillefer, Ballaigues, Swiss) e os sistemas rotatórios Protaper® e Profile® .04/.06(Dentsply/Maillefer, Ballaigues, Swiss). A avaliação das imagens radiográficas, foi realizada por três examinadores independentes e previamente calibrados. Os resultados obtidos permitiram concluir que os melhores instrumentos em ordem decrescente foram: Flexofile®, Protaper®, Nitiflex®, Profile® e a lima Tipo K
2

Avaliação, por meio de microtomografia computadorizada, das alterações na geometria e transporte de canais radiculares com curvatura severa após o preparo biomecânico com diferentes sistemas mecanizados / Micro-CT assessment of geometric changes and root canal transportion in molars with severe curvature after the biomechanical preparation performed by different mechanized systems.

Oliveira, Daniel José Filizola de 28 March 2018 (has links)
O objetivo do presente estudo foi analisar, por meio de microtomografia computadorizada, as alterações bidimensionais (área e perímetro), tridimensionais (volume, área de superfície e SMI) e o transporte do canal nas raízes mesiais de molares inferiores com curvatura severa, após o preparo biomecânico realizado por quatro sistemas de NiTi variando o tipo de cinemática e conceito de preparo, a geometria e design dos instrumentos e o tipo de tratamento da liga. Dessa forma, foram avaliados o sistema rotatório de instrumentos múltiplos Protaper Next (PTN); o sistema reciprocante de instrumento único Reciproc (RC); o sistema reciprocante de instrumento único, Reciproc Blue (RCB) e o sistema rotatório de instrumentos múltiplos TRUShape (TRS). Foram selecionados 32 molares inferiores com ângulo de curvatura da raiz mesial de 25-50º e raio 4 mm, e escaneados em microtomógrafo 1176 (SkyScan, Kontich, Bélgica), com resolução isotrópica de 18 m. Após isso, as imagens foram reconstruídas e analisadas com obtenção dos parâmetros iniciais (pré-instrumentação) bidimensionais de área e perímetro, e tridimensionais de volume, área de superfície e SMI, além do transporte do canal por meio da obtenção dos valores do centroide. Os espécimes foram então distribuídos em grupos experimentais de acordo com o sistema de instrumentação utilizado (n=8), e após a instrumentação, foi realizada nova análise microtromográfica seguindo os padrões iniciais descritos. Os dados pré e pós instrumentação foram tabulados e então realizada a análise estatística por meio de ANOVA e pós teste Tukey, com nível de significância de 5%. Os resultados demonstraram que, independente do sistema de instrumentação, houve alterações dos parâmetros bidimensionais e tridimensionais, como também transporte do canal pós-instrumentação. Não foram observadas diferenças estatisticamente significantes (p>0,05) entre os sistemas RC e RCB, bem como entre os sistemas PTN e TRS em nenhum dos parâmetros analisados (bidimensionais, tridimensionais e transporte do canal). No terço cervical, foram encontradas diferenças estatisticamente significantes (p<0,05) entre os sistemas, com maiores alterações entre RC e RCB, em relação aos sistemas PTN e TRS. No terço apical, não houve diferenças estatisticamente significantes (p>0,05) entre os sistemas, em relação aos parâmetros estudados. Pode-se concluir que os sistemas em estudo, independentemente do número de instrumentos, do tipo de movimento, do tipo de tratamento térmico das ligas e das características particulares de cada instrumento, não promoveram alterações na zona crítica apical, e que os instrumentos de maior conicidade promoveram maiores mudanças na morfologia do canal, de acordo com os parâmetros avaliados / The aim of the present study was to analyze, by micro-CT, the two (area and perimeter) and three (volume, surface area and SMI) dimensional changes and root canal transportation in mesial roots of mandibular molars with severe curvature, after the biomechanical procedures performed by four different NiTi, varying the kinematic type and preparation concept, the geometry and design of the instruments and the type of alloy treatment. In this way, the multi-instrument rotary system Protaper Next (PTN); the reciprocating single file system Reciproc (RC); the reciprocating single file system Reciproc Blue (RCB) and the multi-instrument rotary system TRUShape (TRS), were evaluated. Thirty-two lower molars with mesial root curvature angle of 25-50 ° and radius 4 mm were selected and scanned in a micro-CT 1176 (SkyScan, Kontich, Belgium) with 18 m isotropic resolution. After that, the images were reconstructed and analyzed to obtain the initial parameters (pre-instrumentation) of the area and perimeter, and three-dimensional volume, surface area, and SMI, besides of the root canal transportation by means of the centroid values. The specimens were distributed in experimental groups according to the instrumentation system used (n = 8), and after instrumentation, a new microtomographic analysis was performed following the initial standards described. The pre and post instrumentation data were tabulated and then the statistical analysis was performed using ANOVA and post Tukey test, with a significance level of 5%. The results showed that, regardless of the instrumentation system, changes in the two-dimensional and three-dimensional parameters, as well as the root canal transportation were noticed. No statistically significant differences (p> 0.05) were observed between the RC and RCB systems, as well as between the PTN and TRS systems in none of the analyzed parameters (bidimensional, three-dimensional and root canal transportation). In the cervical third, statistically significant differences (p <0.05) were found between the systems, with greater changes to RC and BCR, in relation to the PTN and TRS systems. In the apical third, there were no statistically significant differences (p> 0.05) between the systems, in relation to the parameters studied. It can be concluded that the systems analyzed in this study, independently of the number of instruments, the type of movement, the type of heat treatment of the alloys and the particular characteristics of each instrument, did not promote changes in the critical apical zone, and that the conicity promoted greater changes in the morphology of the canal, according to the evaluated parameters
3

Analysis of novel ultrasonic tips for the instrumentation and removal of filling material in flattened/oval-shaped root canals: a micro-computed tomographic study / Avaliação de novos insertos ultrassônicos para preparo e desobturação de canais achatados: análise por microtomografia computadorizada

Peña, Melissa Esther Rivera 26 February 2018 (has links)
Aim: To analyse the influence of novel ultrasonic tips on the instrumentation and removal of filling material in flattened/oval-shaped canals. Methodology: Forty-five mandibular incisors were selected and randomly divided into three experimental groups according to different protocols. For the instrumentation procedures, the following protocols were used: Group PFCP: ProDesign Logic 25/.05 + Flatsonic + Clearsonic + Prodesign Logic 40/.01, Group FCP: Flatsonic + Clearsonic + ProDesign Logic 40/.01 and Group PP: Prodesign Logic 25/.05 + Prodesign Logic 40/.05. After the instrumentation procedures, the samples were randomly divided into three experimental groups for the removal of filling material: Group R: Reciproc R25/.08, Group RC: Reciproc R25/.08 + Clearsonic tip and Group CR: Clearsonic tip + Reciproc R25/.08. The teeth were scanned pre and post-operatively by the means of a micro-computed tomography system. The percentage values for increase in volume, non-instrumented surface area, dentine removal, degree of canal transportation, centering ratio and percentage of residual filling material between the experimental groups were examined. Data were analysed using non-parametric Kruskal-Wallis and Dunn\'s tests. The significance level was of P<0.05. Results: The instrumentation technique applied in group PFCP provided the greatest volume increase in the total portion of the root canal, showing the lowest percentage of noninstrumented surface area. Regarding the degree of transportation in the buccolingual direction, statistically significant differences between groups PFCP and PP were observed in the coronal third of the canal. In the mesio-distal direction, no statistically significant differences in the coronal, middle and apical thirds were observed. As for the centering ratio, statistically significant differences were found in the bucco-lingual direction. In the mesio-distal direction, no statistically significant differences in the coronal, middle and apical thirds were observed between the instrumentation protocols used in this study. Statistically significant differences between the experimental groups were found in the total portion of the root canal, where group R provided the highest percentage of residual root canal filling material when compared to groups RC and CR. In group C, the lowest percentage of residual root canal filling material was observed. Concerning the percentage of residual root canal filling material in the apical third of the root canal, statistically significant differences were found between the different protocols used in this study. The technique used in group CR, provided the lowest percentage of residual root canal filling material. Conclusions: The protocol used in the PFCP group provided a significant increase in volume and reduced the percentage of non-instrumented walls during the shaping of oval-shaped canals. The use of the ClearSonic tip as the first instrument followed by the Reciproc 25/.08 file for the removal of filling material, resulted in the lowest percentage of residual filling material in the total portion and in the apical third of the root canal. / Objetivo: Analisar a influência de novos insertos ultrassônicos para o preparo e remoção de material obturador em canais achatados. Metodologia: Quarenta e cinco incisivos inferiores foram selecionados e divididos aleatoriamente em três grupos experimentais dependendo da técnica de preparo e remoção de material obturador. Para o preparo dos espécimes, os seguintes protocolos foram utilizados: Group PFCP: ProDesign Logic 25/.05 + Flatsonic + Clearsonic + Prodesign Logic 40/.01, Group FCP: Flatsonic + Clearsonic + ProDesign Logic 40/.01 and Group PP: Prodesign Logic 25/.05 + Prodesign Logic 40/.05. Posteriormente, os espécimes foram redistribuídos em três grupos experimentais para a remoção do material obturador: Group R: Reciproc R25/.08, Group RC: Reciproc R25/.08 + Clearsonic tip and Group CR: Clearsonic tip + Reciproc R25/.08. Os espécimes foram escaneados antes e após os procedimentos operatórios por meio de micro-tomografia computadorizada. Foram examinados os valores de aumento de volume, área de superfície não tocada, remoção de dentina, grau de transporte do canal, centralização do preparo e material obturador remanescente entre os grupos experimentais. Os dados foram analisados com os testes estatísticos não paramétricos de Kruskal-Wallis e Dunn. O nível de significância foi de 5%. Resultados: A técnica de preparo aplicada no grupo PFCP promoveu o maior aumento de volume na porção total do canal radicular, mostrando a menor porcentagem de área não tocada. Em relação ao grau de transporte no sentido vestíbulo-lingual, diferenças estatísticas significantes foram encontradas no terço cervical entre o grupo PCFP e PP. No sentido mesio-distal, não houve diferença estatística significante nos terços cervical, médio e apical. No que diz respeito a centralização do preparo, diferenças estatísticas significantes foram encontradas no sentido vestíbulo-lingual. Considerando a porcentagem de material obturador remanescente, foram observadas diferenças estatísticas significantes entre os grupos experimentais na porção total do canal radicular, onde o grupo R apresentou a maior porcentagem de material obturador remanescente, quando comparado aos grupo RC e CR. No grupo CR, a menor porcentagem de material obturador remanescente foi constatada. Diferenças estatísticas significantes foram encontradas entre os grupos experimentais na porção apical do canal radicular. Desse modo, a técnica usada no grupo CR, promoveu a menor porcentagem de material obturador remanescente no terço apical. Conclusões: O protocolo utilizado no grupo PFCP promoveu a maior porcentagem de aumento de volume e reduziu a porcentagem de áreas não tocadas durante o preparo de canais achatados. A associação do inserto ultrassônico ClearSonic antes da utilização do instrumento reciprocante R25 para a remoção de material obturador, promoveu a menor porcentagem de material obturador remanescente na porção total e apical do canal radicular.
4

Comparação do desgaste da zona de perigo de molares superiores utilizando o sistema rotatório ProTaper e brocas Gates-Glidden

Carvalho, Flávio Narciso 30 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-20T19:34:56Z No. of bitstreams: 1 flavionarcisocarvalho.pdf: 1211132 bytes, checksum: adfc5e1232b5cff137271982964292ec (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T15:25:51Z (GMT) No. of bitstreams: 1 flavionarcisocarvalho.pdf: 1211132 bytes, checksum: adfc5e1232b5cff137271982964292ec (MD5) / Made available in DSpace on 2016-07-13T15:25:51Z (GMT). No. of bitstreams: 1 flavionarcisocarvalho.pdf: 1211132 bytes, checksum: adfc5e1232b5cff137271982964292ec (MD5) Previous issue date: 2012-03-30 / O objetivo desta pesquisa foi avaliar a espessura dentinária da parede distal das raízes mésio-vestibulares de molares superiores (zona de risco) quando submetida à ação das brocas Gates-Glidden (GG) ou ProTaper, durante processo de instrumentação dos canais radiculares. Para isso foram selecionados 20 molares superiores, que após serem incluídos num bloco de resina de poliéster foram seccionados transversalmente na área entre terço cervical e terço médio (zona de risco). Os espécimes foram fotografados antes e após processo operatório com uma câmera digital Nikon Coolpix 4300 acoplada ao Microscópio Cirúrgico (DF Vasconcelos). Dez amostras tiveram instrumentação realizada nos canais mésio-vestibulares pelas brocas Gates-Glidden (GG) e outras dez nos canais mésio-vestibulares instrumentados pelo sistema rotatório ProTaper. Após a fase de instrumentação os blocos foram novamente fotografados. A menor distância encontrada entre a parede interna do canal e a parede externa referente à zona de risco foi medida, através do programa Image TOOL, antes e após o uso das brocas. Os dados foram tabulados e levados para a análise estatística. Concluiu-se não haver diferença estatisticamente significante no desgaste causado por ambos instrumentos em todos setores analisados. / The aim of this study was to evaluate the thickness of the distal wall ofdentin mesio buccal roots of maxillary molars (risk zone) when subjected to the action of Gates Glidden drills (GG) or ProTaper for process instrumentation of root canals. For this we selected 20 molars, which after being included in a block of polyester resin were sectioned in the area between the cervical third and middle third (risk zone). The specimens were photographed before and after operative process with a Nikon Coolpix 4300 digital camera attached to the surgical microscope (DFVasconcelos). Ten samples were performed in the instrumentationchannels mesiobuccal by Gates Glidden drills (GG) and other ten-university channels mésios instrumented by rotary system ProTaper. After phase instrumentation blocks were photographed again. The shortest distance found between the inner wall of the channel and the outer wall on the risk area was measured using the Image TOOL before and after the use of drills. Data were tabulated and taken for statistical analysis. It was concluded that there was no statistically significant difference in wear caused by both instruments in all sectors analyzed.

Page generated in 0.0696 seconds