• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 7
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da remoção de diferentes materiais obturadores pelo sistema reciprocante seguido de duas técnicas complementares em canais radiculares achatados / Evaluation of the removal of different filling materials using reciprocating system followed by two supplementary techniques in flattened root canals

Crozeta, Bruno Monguilhott 18 April 2018 (has links)
O objetivo do presente estudo foi avaliar, por meio de microtomografia computadorizada (micro-CT), o volume de remanescente de diferentes materiais obturadores (AH Plus e BC Sealer), após o uso do instrumento R50 e de técnicas complementares (inserto ultrassônico e instrumento XP-endo Finisher R) em canais radiculares ovais. Vinte e oito raízes distais de molares inferiores, com canal único e oval, foram selecionadas por micro-CT, preparados com instrumento R40 (40.06), e obturados com os seguintes cimentos: AH Plus (n = 14) e BC Sealer (n = 14), e submetidos à ciclagem térmica. Em seguida foi realizada a remoção inicial com R50 e os dentes foram escaneados no micro-CT para determinação do volume remanescente inicial de material obturador, e posterior complementação com inserto ultrassônico (n = 7) ou XP-endo Finisher R (n = 7). Os espécimes foram novamente escaneados, e a partir do volume inicial de material obturador (volinicial) e volume de material obturador remanescente (volrem) em mm3, obteve-se a % de volume de material remanescente após as técnicas de complementação (%volrem=volrem×100/volinicial). Para a análise qualitativa, as imagens de MEV e os modelos tridimensionais obtidos por micro-CT, foram avaliados em relação à presença/ausência e localização do remanescente de material obturador nos canais radiculares. Os dados de %volrem e volume remanescente de material obturador após o uso do instrumento R50 (%volR50) foram comparados pelo teste T, e os dados de %volrem foram submetidos ao teste ANOVA, seguido de teste de Tukey (nível de probabilidade de 95%). Considerando o canal como um todo, as técnicas de complementação promoveram redução significativa do volume remanescente de material obturador, sendo que menores valores foram observados quando utilizado o inserto ultrassônico (8,93 ± 6,12) em relação ao XP-endo Finisher R (16,26 ± 14,71) (P = 0,043). Quanto aos cimentos, pode-se observar que o BC Sealer apresentou maiores quantidades de remanescente (18,87 ± 13,42) quando comparado ao cimento AH Plus (6,33 ± 4,25) (P < 0,001). Em relação à avaliação por terços radiculares, observou-se que quando utilizado o instrumento XP-endo Finisher R, não houve diferença do volume de material remanescente entre os terços, independente do cimento obturador utilizado (P > 0,05). Entretanto, ao se utilizar inserto ultrassônico e cimento AH Plus, maiores valores de volume de material remanescente foram observados no terço apical (23,08 ± 18,1) (P < 0,001), e quando utilizado o BC Sealer, no terço médio (15,53 ± 6,0) (P = 0,022). Conclui-se que as técnicas de complementação aumentaram a remoção de material obturador, entretanto, nenhuma das técnicas removeu por completo o material obturador do canal radicular, principalmente quando o dente foi obturado com o cimento BC Sealer / The aim of the present study was to evaluate, by micro-computed tomography (micro-CT), the remaining volume of different filling materials (AH Plus and BC Sealer) after using the R50 instrument and supplementary techniques (ultrasonic insert and XP-endo Finisher R instrument) in oval-shaped root canals. Twenty-eight distal roots of mandibular molars with single and oval-shaped canals, verified by micro-CT, were prepared with R40 instrument (40.06), and filled with the following sealers: AH Plus (n = 14) and BC Sealer (n = 14), and subjected to thermocycling. Then, the initial removal was performed with R50 and the samples were scanned in micro-CT to determine the initial remaining filling material volume, and subjected to the supplementary techniques with ultrasonic tip (n = 7) or XP-endo Finisher R (n = 7). The specimens were again scanned, and the initial volume of filling material (volinitial) and the final volume of filling material after the supplementary techniques (volfinal), obtained in mm3, were used to calculate the volume % of remaining filling material (%volrem=volrem×100/volinitial). For the qualitative analysis, the SEM images and the three-dimensional models obtained by micro-CT were evaluated regarding the presence/absence and location of the remaining filling material in the root canals after retreatment. The data of %volrem and volume of the remaining filling material after R50 (%volR50) were compared by the T test, and the %volrem data were submitted to the ANOVA and Tukey tests (95% probability level). Considering the entire root canal, the supplementary techniques promoted significant reduction of the volume of the remaining filling material, and lower values were observed for the ultrasonic tip (8.93 ± 6.12) when compared to XP-endo Finisher R (16.26 ± 14.71) (P = 0.043). Regarding the different sealers, BC Sealer presented higher amounts of remaining material (18.87 ± 13.42) when compared to AH Plus (6.33 ± 4.25) (P <0.001). The evaluation by root thirds showed that when the XP-endo Finisher R instrument was used, there was no difference in the volume of remaining material between the thirds, regardless the sealer used (P > 0.05). However, when using ultrasonic tip and AH Plus, higher values were observed in the apical third (23.08 ± 18.1) (P <0.001), and when the BC Sealer was used, in the middle third 15.53 ± 6.0) (P = 0.022). It was concluded that supplementary techniques increased the removal, however, none of the techniques completely removed the root canal filling material, especially when the tooth was filled with BC Sealer. with R40 instrument (40.06), and filled with the following sealers: AH Plus (n = 14) and BC Sealer (n = 14), and subjected to thermocycling. Then, the initial removal was performed with R50 and the samples were scanned in micro-CT to determine the initial remaining filling material volume, and subjected to the supplementary techniques with ultrasonic tip (n = 7) or XP-endo Finisher R (n = 7). The specimens were again scanned, and the initial volume of filling material (volinitial) and the final volume of filling material after the supplementary techniques (volfinal), obtained in mm3, were used to calculate the volume % of remaining filling material (%volrem=volrem×100/volinitial). For the qualitative analysis, the SEM images and the three-dimensional models obtained by micro-CT were evaluated regarding the presence/absence and location of the remaining filling material in the root canals after retreatment. The data of %volrem and volume of the remaining filling material after R50 (%volR50) were compared by the T test, and the %volrem data were submitted to the ANOVA and Tukey tests (95% probability level). Considering the entire root canal, the supplementary techniques promoted significant reduction of the volume of the remaining filling material, and lower values were observed for the ultrasonic tip (8.93 ± 6.12) when compared to XP-endo Finisher R (16.26 ± 14.71) (P = 0.043). Regarding the different sealers, BC Sealer presented higher amounts of remaining material (18.87 ± 13.42) when compared to AH Plus (6.33 ± 4.25) (P <0.001). The evaluation by root thirds showed that when the XP-endo Finisher R instrument was used, there was no difference in the volume of remaining material between the thirds, regardless the sealer used (P > 0.05). However, when using ultrasonic tip and AH Plus, higher values were observed in the apical third (23.08 ± 18.1) (P <0.001), and when the BC Sealer was used, in the middle third 15.53 ± 6.0) (P = 0.022). It was concluded that supplementary techniques increased the removal, however, none of the techniques completely removed the root canal filling material, especially when the tooth was filled with BC Sealer
2

Avaliação, por meio de microtomografia computadorizada, das alterações na geometria e transporte de canais radiculares com curvatura severa após o preparo biomecânico com diferentes sistemas mecanizados / Micro-CT assessment of geometric changes and root canal transportion in molars with severe curvature after the biomechanical preparation performed by different mechanized systems.

Oliveira, Daniel José Filizola de 28 March 2018 (has links)
O objetivo do presente estudo foi analisar, por meio de microtomografia computadorizada, as alterações bidimensionais (área e perímetro), tridimensionais (volume, área de superfície e SMI) e o transporte do canal nas raízes mesiais de molares inferiores com curvatura severa, após o preparo biomecânico realizado por quatro sistemas de NiTi variando o tipo de cinemática e conceito de preparo, a geometria e design dos instrumentos e o tipo de tratamento da liga. Dessa forma, foram avaliados o sistema rotatório de instrumentos múltiplos Protaper Next (PTN); o sistema reciprocante de instrumento único Reciproc (RC); o sistema reciprocante de instrumento único, Reciproc Blue (RCB) e o sistema rotatório de instrumentos múltiplos TRUShape (TRS). Foram selecionados 32 molares inferiores com ângulo de curvatura da raiz mesial de 25-50º e raio 4 mm, e escaneados em microtomógrafo 1176 (SkyScan, Kontich, Bélgica), com resolução isotrópica de 18 m. Após isso, as imagens foram reconstruídas e analisadas com obtenção dos parâmetros iniciais (pré-instrumentação) bidimensionais de área e perímetro, e tridimensionais de volume, área de superfície e SMI, além do transporte do canal por meio da obtenção dos valores do centroide. Os espécimes foram então distribuídos em grupos experimentais de acordo com o sistema de instrumentação utilizado (n=8), e após a instrumentação, foi realizada nova análise microtromográfica seguindo os padrões iniciais descritos. Os dados pré e pós instrumentação foram tabulados e então realizada a análise estatística por meio de ANOVA e pós teste Tukey, com nível de significância de 5%. Os resultados demonstraram que, independente do sistema de instrumentação, houve alterações dos parâmetros bidimensionais e tridimensionais, como também transporte do canal pós-instrumentação. Não foram observadas diferenças estatisticamente significantes (p>0,05) entre os sistemas RC e RCB, bem como entre os sistemas PTN e TRS em nenhum dos parâmetros analisados (bidimensionais, tridimensionais e transporte do canal). No terço cervical, foram encontradas diferenças estatisticamente significantes (p<0,05) entre os sistemas, com maiores alterações entre RC e RCB, em relação aos sistemas PTN e TRS. No terço apical, não houve diferenças estatisticamente significantes (p>0,05) entre os sistemas, em relação aos parâmetros estudados. Pode-se concluir que os sistemas em estudo, independentemente do número de instrumentos, do tipo de movimento, do tipo de tratamento térmico das ligas e das características particulares de cada instrumento, não promoveram alterações na zona crítica apical, e que os instrumentos de maior conicidade promoveram maiores mudanças na morfologia do canal, de acordo com os parâmetros avaliados / The aim of the present study was to analyze, by micro-CT, the two (area and perimeter) and three (volume, surface area and SMI) dimensional changes and root canal transportation in mesial roots of mandibular molars with severe curvature, after the biomechanical procedures performed by four different NiTi, varying the kinematic type and preparation concept, the geometry and design of the instruments and the type of alloy treatment. In this way, the multi-instrument rotary system Protaper Next (PTN); the reciprocating single file system Reciproc (RC); the reciprocating single file system Reciproc Blue (RCB) and the multi-instrument rotary system TRUShape (TRS), were evaluated. Thirty-two lower molars with mesial root curvature angle of 25-50 ° and radius 4 mm were selected and scanned in a micro-CT 1176 (SkyScan, Kontich, Belgium) with 18 m isotropic resolution. After that, the images were reconstructed and analyzed to obtain the initial parameters (pre-instrumentation) of the area and perimeter, and three-dimensional volume, surface area, and SMI, besides of the root canal transportation by means of the centroid values. The specimens were distributed in experimental groups according to the instrumentation system used (n = 8), and after instrumentation, a new microtomographic analysis was performed following the initial standards described. The pre and post instrumentation data were tabulated and then the statistical analysis was performed using ANOVA and post Tukey test, with a significance level of 5%. The results showed that, regardless of the instrumentation system, changes in the two-dimensional and three-dimensional parameters, as well as the root canal transportation were noticed. No statistically significant differences (p> 0.05) were observed between the RC and RCB systems, as well as between the PTN and TRS systems in none of the analyzed parameters (bidimensional, three-dimensional and root canal transportation). In the cervical third, statistically significant differences (p <0.05) were found between the systems, with greater changes to RC and BCR, in relation to the PTN and TRS systems. In the apical third, there were no statistically significant differences (p> 0.05) between the systems, in relation to the parameters studied. It can be concluded that the systems analyzed in this study, independently of the number of instruments, the type of movement, the type of heat treatment of the alloys and the particular characteristics of each instrument, did not promote changes in the critical apical zone, and that the conicity promoted greater changes in the morphology of the canal, according to the evaluated parameters
3

Análise bi e tridimensional das alterações morfológicas em raízes mesiais de molares inferiores com curvaturas severas preparados por diferentes sistemas mecanizados. Estudo por microtomografia computadorizada / Bi and three-dimensional analysis of morphological alterations in mesial roots of mandibular molars with severe curvatures prepared by different mechanized systems. Computerized microtomography study

Flamini, Luís Eduardo Souza 19 April 2017 (has links)
O presente estudo teve como objetivo analisar, por meio de microtomografia computadorizada, os parâmetros morfológicos das raízes mesiais de molares inferiores, preparados por três sistemas mecanizados: reciprocante (Reciproc - RC), rotatório contínuo (OneShape - OS) e reciprocante/rotatório (Twisted-File Adaptive - TFA), precedidos ou não de pré-alargamento (ProGlider - PG). Foram utilizados trinta molares inferiores, com raiz mesial apresentando ângulo (&ge;25º) e raio de curvatura (&le;2mm) severos e dois canais distintos. Por meio da técnica de amostragem estratificada, os canais foram distribuídos em seis grupos (n=10) conforme protocolo de instrumentação: G1-TFA; G2-RC; G3-OS; G4-PG + TFA; G5 - PG + RC; G6- PG + OS. Após o preparo, foram avaliados os parâmetros bidimensionais (área, perímetro, circularidade, diâmetro maior e menor) nos 5mm apicais e tridimensionais (volume, área de superfície e SMI), bem como o transporte do canal radicular. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA seguido do complementar de Tukey (&alpha;=0,05). O RC apresentou valores, significantemente, maiores de área, perímetro e diâmetro menor em relação ao TFA (p<0,001), não havendo diferença significante entre os sistemas em relação à circularidade (p=0,056) e diâmetro maior (p=0,477). O aumento do volume do canal proporcionado pelos sistemas RC e OS foram semelhantes entre si (p=0,979) e diferente estatisticamente ao TFA (p<0,001). O aumento da área de superfície promovida pelo RC foi similar ao OS (p=0,254) e diferente estatisticamente ao TFA (p=0,001), não havendo diferença entre os dois últimos sistemas (p=0,075). Os valores de SMI do grupo PG + OS foram significativamente maiores que dos demais grupos (p<0,001). Não houve diferença entre os sistemas em relação ao transporte nos terços apical e médio. Concluiu-se que todos os sistemas avaliados apresentaram alterações morfológicas bi e tridimensionais após o preparo biomecânico. O emprego do sistema ProGlider previamente aos sistemas de instrumentação não influenciou as alterações dos parâmetros avaliados. / The present study aimed to analyze, by computerized microtomography, the morphological parameters of mesial roots of mandibular molars prepared by three mechanized systems: reciprocating (Reciproc - RC), continuous rotating (OneShape - OS) and Twisted - File Adaptive (TFA), preceded or not by pre - enlargement (ProGlider-PG). Thirty teeth were used, with mesial root presenting severe angle (&ge;25º) and a radius of curvature (&le;2mm) and two distinct canals. By means of the stratified sampling technique, the canals were distributed in six groups (n = 10) according to the instrumentation protocol: G1-TFA; G2-RC; G3-OS; G4-PG + TFA; G5 - PG + RC; G6- PG + OS. After preparation, the two-dimensional parameters (area, perimeter, roundness, major and minor diameter) were evaluated in the apical 5mm as well as three-dimensional parameters (volume, surface area and SMI) and root canal transportation. The data were statistically analyzed using the ANOVA test followed by Tukey\'s complement (&alpha; = 0.05). The RC presented significantly larger values of area, perimeter, and minor diameter in relation to the TFA (p<0,001), and there was no significant difference between the systems in relation to the roundness (p=0,056) and major diameter (p=0,477). The increased canal volume provided by the RC and the OS systems were similar to each other (p=0,979) and statistically different from the TFA (p<0,001). The increase of the surface area promoted by the RC was similar to the OS (p=0,254) and statistically different to the TFA (p=0,001), with no difference between the other two systems (p=0,075). The SMI values of the PG + OS group were significantly higher than the other groups (p<0,001). There was no difference between the systems in relation to transport in the apical and middle thirds. It was concluded that all evaluated systems presented bi-dimensional and three-dimensional morphological alterations after biomechanical preparation. The use of the ProGlider system prior to the instrumentation systems did not influence the parameters evaluated.
4

Estudo imaginológico da regeneração óssea guiada associada ou não à terapia de fotobiomodulação (PBMT) em ratas com osteoporose / Imaging study of guided bone regeneration associated or not with photobiomodulation therapy (PBMT) in rats with osteoporosis

Alves, Fernando Amorim Mendonça 14 September 2018 (has links)
A osteoporose é uma doença sistêmica caracterizada pela perda de conteúdo mineral do osso propiciando fraturas críticas. A regeneração óssea guiada e a terapia de fotobiomodulação (PBMT do inglês photobiomodulation therapy) favorecem a regeneração óssea. O objetivo do estudo foi avaliar o efeito da PBMT no reparação óssea guiada de lesões críticas de 36 ratas com osteoporose induzida por ooforectomia. Foram realizadas lesões ósseas estandardizadas nos ossos parietais e então tratadas de acordo com os seguintes grupos experimentais (n=12 lesões por grupo): Controle: sem tratamento adicional; Membrana - Colocação de uma membrana de colágeno suíno comercial (Bio-Gide®) dentro do leito cirúrgico; PBMT1- membrana e aplicação da PBMT1; PBMT2- membrana e aplicação da PBMT2. A PBMT foi realizada com laser de diodo infravermelho no modo contínuo, pontual e em contato (808nm, 40mW, 1,42W/cm2; PBMT1: 3s, 4J/cm2, 0,12J por ponto e PBMT2: 10s, 14J/cm2, 0,4J por ponto) imediatamente, 48 e 96 horas após a cirurgia. Quatro e oito semanas após a cirurgia os animais foram eutanasiados, a calota craniana dissecada, fixada e submetida à análise por microtomografia computadorizada. Foram coletados os seguintes dados: volume ósseo relativo (razão entre o volume ósseo e o volume total), número, espessura e separação de trabéculas, conectividade por densidade e índice de estrutura de modelo (SMI do inglês structure model index). Os dados de cada análise foram comparados pelo teste ANOVA dois critérios/Tukey ou Kruskal Wallis/Dunn e os dados de análises diferentes pelo teste de correlação de Spearman (p<0,05). Diferenças significativas foram observadas em 8 semanas. A PBMT, em especial nos parâmetros de menor energia (0,12J), acelerou o reparo ósseo resultando na obtenção de maior volume ósseo, com grande número de trabéculas, de espessura média, próximas e interconectadas e com valores baixos de SMI. Dentro das limitações deste trabalho in vivo, concluímos que a PBMT acelera a formação e maturação do tecido ósseo neoformado em lesões ósseas críticas de ratas osteoporóticas. / Osteoporosis is a systemic disease characterized by loss of bone mineral content leading to critical fractures. Guided bone regeneration and photobiomodulation therapy (PBMT) favor bone regeneration. The objective of the study was to evaluate the effect of PBMT on the guided bone repair of critical lesions of 36 rats with osteoporosis induced by oophorectomy. Standardized bone lesions were performed on the parietal bones and then treated according to the following experimental groups (n = 12 lesions per group): Control: no additional treatment; Membrane - Placement of a commercial swine collagen membrane (Bio-Gide®) within the surgical bed; PBMT1 membrane and PBMT1 application; PBMT2-membrane and PBMT2 application. PBMT was performed with continuous wave infrared diode lasers in punctual and contact mode (808nm, 40mW, 1.42W / cm2, PBMT1: 3s, 4J / cm2, 0,12J per ponit and PBMT2: 10s, 14J / cm2, 0.4J per point) immediately, 48 and 96 hours after surgery. Four and eight weeks after surgery, the animals were euthanized, the skulls dissected, fixed and submitted to the analysis by computerized microtomography. The following data were collected: bone volume, relative bone volume (ratio of bone volume to total volume), number, thickness and separation of trabeculae, density connectivity and model structure index (SMI). The data from each analysis were compared using the ANOVA two criteria / Tukey or Kruskal Wallis / Dunn test and the different analysis data by the Spearman correlation test (p <0.05). Significant differences were observed at 8 weeks. PBMT, especially in the lower energy parameters (0.12J), accelerated bone repair resulting in higher bone volume, with a large number of trabeculae, medium thickness, close to each other and interconnected, and with low SMI values. Within the limitations of this in vivo study, we concluded that PBMT accelerates the formation and maturation of neoformed bone tissue in critical bone lesions of osteoporotic rats.
5

Efeitos da sitagliptina no tecido ósseo em ratos diabéticos e não diabéticos / Effects of sitagliptin on bone tissue in diabetic and non-diabetic rats

Bautista, Cristhian Reynaldo Gomez 30 May 2018 (has links)
Submitted by Cristhian Reynaldo Gomez Bautista (cristhian_rey88@hotmail.com) on 2018-06-06T19:32:09Z No. of bitstreams: 1 Dissertação_Final.pdf: 1036748 bytes, checksum: 062ca5e9451ec3a79709fe89e619d109 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-06-06T19:44:21Z (GMT) No. of bitstreams: 1 bautista_crg_me_sjc.pdf: 1036748 bytes, checksum: 062ca5e9451ec3a79709fe89e619d109 (MD5) / Made available in DSpace on 2018-06-06T19:44:21Z (GMT). No. of bitstreams: 1 bautista_crg_me_sjc.pdf: 1036748 bytes, checksum: 062ca5e9451ec3a79709fe89e619d109 (MD5) Previous issue date: 2018-05-30 / A diabetes mellitus, doença caracterizada pelo aumento da glicemia no sangue, é um dos mais importantes problemas de saúde pública do mundo, com incidência crescente, sobretudo em países em desenvolvimento. Novas terapias medicamentosas para controlar os níveis de glicose no sangue têm sido desenvolvidas, entre elas, os inibidores da enzima dipeptidil peptidase-4 (DPP-4) como a sitagliptina. Pesquisas atuais mostram que este medicamento, além do controle da glicemia, contribui na estimulação da formação e inibição da reabsorção óssea e possui ação anti-inflamatória. O objetivo deste trabalho foi avaliar os efeitos da sitagliptina no tecido ósseo em ratos diabéticos e não diabéticos. Foram utilizados 38 ratos machos, divididos em 4 grupos: Grupo diabético tratado com sitagliptina (GDS- 10 mg/Kg/dia); Grupo diabético (GD); Grupo normoglicêmico tratado sitagliptina (GNS-10 mg/Kg/dia); Grupo normoglicêmico (GN). Para indução da diabetes os animais receberam solução 10% de frutose na água de beber por 14 dias, após o quê receberam 40 mg/Kg de estreptozotocina via intraperitoneal. Quatro semanas depois, avaliou-se a glicemia e iniciou-se o tratamento com sitagliptina nos grupos GDS e GNS, que continuou por mais 4 semanas, quando ocorreu a eutanásia. A glicemia e a resistência à insulina (HOMA-IR) foram avaliadas também no dia da eutanásia. As tíbias foram removidas e avaliadas a porcentagem de volume ósseo (BV/TV), espessura trabecular (Tb.Th), número de trabéculas (Tb.N) e a separação de trabéculas (Tb Sp) da metáfise tibiana por microtomografia computadorizada. Os dados foram submetidos à análise estatística, ao nível de 0,05. Os animais dos grupos GD e GDS apresentaram maior glicemia que os animais dos demais grupos, mas não houve diferença entre os grupos com relação aos dados de HOMA-IR, evidenciando a indução de diabetes do tipo I. Os animais diabéticos apresentaram menor BV/TV e Tb.N, e maior Tb.Sp. Não houve diferença com relação à Tb.Th. O modelo experimental foi eficaz para a indução da diabetes, mas o tratamento com sitagliptina não foi suficiente para reverter os efeitos da diabetes no tecido ósseo. / Diabetes mellitus, a disease characterized by increased blood glucose levels, is one of the most important public health problems in the world, with a growing incidence, especially in developing countries. New drug therapies to control blood glucose levels have been developed, including dipeptidyl peptidase-4 (DPP-4) inhibitors such as sitagliptin. Current research shows that this drug, in addition to glycemic control, contributes to stimulate the formation and inhibition of bone resorption and has an anti-inflammatory action. The aim of this study was to evaluate the effects of sitagliptin on bone tissue in diabetic and non-diabetic rats. Thirty-eight male rats were divided into four groups: Diabetic group treated with sitagliptin (GDS-10 mg / kg / day); Diabetic group (GD); normoglycemic group treated with sitagliptin (GNS-10 mg / kg / day); normoglycemic group (GN). For induction of diabetes the animals received 10% solution of fructose in the drinking water for 14 days, after which they received 40 mg / kg streptozotocin intraperitoneally. Four weeks later, glycemia was evaluated and sitagliptin treatment was started in the GDS and GNS groups, which continued for another 4 weeks, when euthanasia occurred. Blood glucose and insulin resistance (HOMA-IR) were also evaluated on the day of sacrifice. Bone volume (BV/TV), trabecular thickness (Tb.Th), number of trabeculae (Tb.N) and trabeculae separation (Tb.Sp) of the tibial metaphysis were evaluated by computerized microtomography. Data were submitted to statistical analysis at the 0.05 level. The animals of groups GD and GDS presented higher glycemia, but there was no difference regarding HOMA-IR, evidencing diabetes type I induction. The animals in which diabetes was induced presented lower BV/TV and Tb.N, and higher Tb.Sp. There was no difference among groups in TB.Th. The experimental model was sufficient for the induction of diabetes, but treatment with sitagliptin was not enough to reverse the effects of diabetes on bone tissue.
6

Análise bi e tridimensional das alterações morfológicas em raízes mesiais de molares inferiores com curvaturas severas preparados por diferentes sistemas mecanizados. Estudo por microtomografia computadorizada / Bi and three-dimensional analysis of morphological alterations in mesial roots of mandibular molars with severe curvatures prepared by different mechanized systems. Computerized microtomography study

Luís Eduardo Souza Flamini 19 April 2017 (has links)
O presente estudo teve como objetivo analisar, por meio de microtomografia computadorizada, os parâmetros morfológicos das raízes mesiais de molares inferiores, preparados por três sistemas mecanizados: reciprocante (Reciproc - RC), rotatório contínuo (OneShape - OS) e reciprocante/rotatório (Twisted-File Adaptive - TFA), precedidos ou não de pré-alargamento (ProGlider - PG). Foram utilizados trinta molares inferiores, com raiz mesial apresentando ângulo (&ge;25º) e raio de curvatura (&le;2mm) severos e dois canais distintos. Por meio da técnica de amostragem estratificada, os canais foram distribuídos em seis grupos (n=10) conforme protocolo de instrumentação: G1-TFA; G2-RC; G3-OS; G4-PG + TFA; G5 - PG + RC; G6- PG + OS. Após o preparo, foram avaliados os parâmetros bidimensionais (área, perímetro, circularidade, diâmetro maior e menor) nos 5mm apicais e tridimensionais (volume, área de superfície e SMI), bem como o transporte do canal radicular. Os dados obtidos foram analisados estatisticamente por meio do teste ANOVA seguido do complementar de Tukey (&alpha;=0,05). O RC apresentou valores, significantemente, maiores de área, perímetro e diâmetro menor em relação ao TFA (p<0,001), não havendo diferença significante entre os sistemas em relação à circularidade (p=0,056) e diâmetro maior (p=0,477). O aumento do volume do canal proporcionado pelos sistemas RC e OS foram semelhantes entre si (p=0,979) e diferente estatisticamente ao TFA (p<0,001). O aumento da área de superfície promovida pelo RC foi similar ao OS (p=0,254) e diferente estatisticamente ao TFA (p=0,001), não havendo diferença entre os dois últimos sistemas (p=0,075). Os valores de SMI do grupo PG + OS foram significativamente maiores que dos demais grupos (p<0,001). Não houve diferença entre os sistemas em relação ao transporte nos terços apical e médio. Concluiu-se que todos os sistemas avaliados apresentaram alterações morfológicas bi e tridimensionais após o preparo biomecânico. O emprego do sistema ProGlider previamente aos sistemas de instrumentação não influenciou as alterações dos parâmetros avaliados. / The present study aimed to analyze, by computerized microtomography, the morphological parameters of mesial roots of mandibular molars prepared by three mechanized systems: reciprocating (Reciproc - RC), continuous rotating (OneShape - OS) and Twisted - File Adaptive (TFA), preceded or not by pre - enlargement (ProGlider-PG). Thirty teeth were used, with mesial root presenting severe angle (&ge;25º) and a radius of curvature (&le;2mm) and two distinct canals. By means of the stratified sampling technique, the canals were distributed in six groups (n = 10) according to the instrumentation protocol: G1-TFA; G2-RC; G3-OS; G4-PG + TFA; G5 - PG + RC; G6- PG + OS. After preparation, the two-dimensional parameters (area, perimeter, roundness, major and minor diameter) were evaluated in the apical 5mm as well as three-dimensional parameters (volume, surface area and SMI) and root canal transportation. The data were statistically analyzed using the ANOVA test followed by Tukey\'s complement (&alpha; = 0.05). The RC presented significantly larger values of area, perimeter, and minor diameter in relation to the TFA (p<0,001), and there was no significant difference between the systems in relation to the roundness (p=0,056) and major diameter (p=0,477). The increased canal volume provided by the RC and the OS systems were similar to each other (p=0,979) and statistically different from the TFA (p<0,001). The increase of the surface area promoted by the RC was similar to the OS (p=0,254) and statistically different to the TFA (p=0,001), with no difference between the other two systems (p=0,075). The SMI values of the PG + OS group were significantly higher than the other groups (p<0,001). There was no difference between the systems in relation to transport in the apical and middle thirds. It was concluded that all evaluated systems presented bi-dimensional and three-dimensional morphological alterations after biomechanical preparation. The use of the ProGlider system prior to the instrumentation systems did not influence the parameters evaluated.
7

Avaliação da resistência da união de cimentos obturadores resinosos à dentina radicular, por meio do teste push-out acoplado ao microtomógrafo / Evaluation of bond strength of resin-based sealers to radicular dentin by push-out test coupled to a microtomography

Brito Júnior, Manoel 05 December 2014 (has links)
O objetivo deste estudo foi avaliar a resistência de união à dentina da obturação de canais radiculares com cimentos à base de resina epóxica e de metacrilato, por meio do dispositivo material testing stage (MTS) acoplado ao microtomógrafo (&mu;CT), bem como avaliar qualitativamente a ruptura da massa obturadora por meio de imagens de &mu;CT. Além disso, foram utilizados o método de elementos finitos 3D e microscopia confocal de varredura a laser (MCVL) para verificar, respectivamente, a distribuição de tensões e presença de gaps na interface de união. Raízes de caninos superiores com 17 mm de comprimento foram submetidas ao preparo biomecânico com instrumentos rotatórios de níquel titânio, sob irrigação constante com NaOCl 1% e irrigação final com EDTA 17%. Os canais foram obturados pela técnica da condensação lateral com cones de guta percha e os cimentos: AH Plus, Epiphany SE ou RealSeal XT. As raízes foram armazenadas (100% de umidade, 37°C) por três vezes o tempo de endurecimento do cimento utilizado. Após este período, as raízes foram seccionadas para obtenção de dois slices (2 mm) de cada terço radicular. Um slices de cada terço foi submetido ao teste de push-out através de dispositivo mecânico MTS acoplado ao &mu;CT SkyScan 1174 (50kV, 80mA). Após o escaneamento inicial do slices, com resolução isotrópica de 13 &mu;m, filtro de 0.5 mm de Al e 360º de rotação, o teste mecânico foi iniciado até que ocorresse o deslocamento do material. Novo escaneamento foi realizado com os mesmos parâmetros iniciais, que determinou regiões de ruptura da massa obturadora em secções axiais. Os tipos de falhas foram avaliados por MCVL e classificadas em: adesivas, coesivas e mistas. Modelos 3D de elementos finitos foram gerados para os terços cervical, médio e apical, a partir de imagens de &mu;CT. No segundo slices de cada terço radicular, foi aferido o percentual de gaps do material obturador às paredes do canal radicular, por meio de MCVL e do programa OLS 4000. Os dados foram analisados por testes estatísticos paramétricos e não paramétricos (p<0,05). O cimento AH Plus [1,89 (1,01/2,39) MPa] apresentou maior resistência de união à dentina (p<0,001) quando comparado aos cimentos Epiphany SE [0,36 (0,29/0,44) MPa] e RealSeal XT [0,43 (0,32/0,54) MPa]. Para os cimentos AH Plus e RealSeal XT, os terços cervical e médio apresentaram maior resistência de união à dentina que o terço apical (p<0,001). As rupturas ocorreram nas margens da massa obturadora para o cimento AH Plus, enquanto os cimentos Epiphany SE e RealSeal XT tiveram este tipo de ruptura, bem como na própria massa obturadora. No cimento AH Plus, a interface de união mostrou maior concentração de tensões, que foram distribuídas principalmente na massa obturadora para os cimentos Epiphany SE e RealSeal XT. Houve predominância de falhas adesivas e mistas em todos os cimentos. Em relação ao percentual de gaps, o cimento AH Plus apresentou as menores médias (11,14% ± 4,03), com diferença estatisticamente significante (p<0,05) dos cimentos Epiphany SE (55,39% ± 13,46) e RealSeal XT (62,50% ± 6,72). O cimento à base de resina epóxica (AH Plus) apresentou a maior resistência de união à dentina e teve comportamento diferente em relação aos outros cimentos, quanto à ruptura da massa obturadora e distribuição de tensão interfacial. Além disso, o cimento AH Plus apresentou o menor percentual de gaps entre o material obturador e as paredes do canal radicular / The aim of this study was to evaluate the bond strength of epoxy resin- and methacrylate-based sealers to root dentin, using the material testing stage (MTS) coupled to a micro-computed tomography (&mu;CT) device and to qualitatively assess the root-filling mass rupture by &mu;CT images. Additional analyses were conducted using the 3D element finite method and confocal laser scanning microscopy (CLSM) to verify, respectively, the stress distribution and percentage of gaps on dentin filling material interfaces. Maxillary canine roots measuring 17 mm were subjected to biomechanical preparation with nickel-titanium rotary instruments under constant irrigation with 1% NaOCl and final irrigation with 17% EDTA. Canals were filled by the lateral condensation technique with gutta-percha cones and the following sealers: AH Plus, Epiphany SE or RealSeal XT. The roots were stored (100% humidity, 37 °C) for a period three times longer than the setting time required for each sealer and then sectioned transversally to obtain two 2-mm-thick slices from each root third. One slice of each third was subjected to the push-out test using the MTS coupled to the SkyScan 1174 &mu;CT (50 kV, 80 mA) with 13 &mu;m isotropic resolution, 0.5 mm Al filter and 360° rotation. After the initial scanning of the slice, the mechanical test was performed until material dislodgement occurred. A new scanning was performed using the same initial parameters. The axial sections obtained were used for qualitative evaluation of the root-filling mass rupture. Failure modes were assessed by CLSM and classified as adhesive, cohesive or mixed. 3D &mu;CT based finite element models were generated from cervical, middle and apical root thirds to simulate the push-out test. The second slice of each root third was used to assess the percentage of gaps between the filling material and the root canal walls, using CLSM with the aid of the OLS 4000 software. The data were analyzed by parametric and non-parametric tests (p<0.05). AH Plus presented higher bond strength [1.89 (1.01/2.39) MPa] to dentin (p<0.001) than Epiphany SE [0.36 (0.29/0.44) MPa] and RealSeal XT [0.43 (0.32/0.54) MPa]. For AH Plus and RealSeal XT sealers, the cervical and middle thirds showed higher bond strength to dentin than the apical third (p <0.001). The ruptures occurred in the margins of the root filling mass for AH Plus, while Epiphany SE and RealSeal XT had this type of rupture as well as in the root filling mass itself. AH Plus showed stress concentration on bond interface, while in Epiphany SE and RealSeal XT the stress was mainly distributed on the root-filling mass. Adhesive and mixed failures were the predominant fracture modes in all sealers. Regarding the percentage of gaps between the filling material and the root canal walls, AH Plus presented the lowest means (11.14%±4.03), differing significantly (p<0.05) from Epiphany SE (55.39%±13.46) and RealSeal XT (62.50%±6.72) sealers. The epoxy resin-based sealer (AH Plus) presented the highest bond strength to dentin, which had different behavior from other sealers regarding root-filling mass rupture and interfacial stress distribution. Moreover, AH Plus resulted in the lowest percentage of gaps between the material and the root canal walls
8

Avaliação da resistência da união de cimentos obturadores resinosos à dentina radicular, por meio do teste push-out acoplado ao microtomógrafo / Evaluation of bond strength of resin-based sealers to radicular dentin by push-out test coupled to a microtomography

Manoel Brito Júnior 05 December 2014 (has links)
O objetivo deste estudo foi avaliar a resistência de união à dentina da obturação de canais radiculares com cimentos à base de resina epóxica e de metacrilato, por meio do dispositivo material testing stage (MTS) acoplado ao microtomógrafo (&mu;CT), bem como avaliar qualitativamente a ruptura da massa obturadora por meio de imagens de &mu;CT. Além disso, foram utilizados o método de elementos finitos 3D e microscopia confocal de varredura a laser (MCVL) para verificar, respectivamente, a distribuição de tensões e presença de gaps na interface de união. Raízes de caninos superiores com 17 mm de comprimento foram submetidas ao preparo biomecânico com instrumentos rotatórios de níquel titânio, sob irrigação constante com NaOCl 1% e irrigação final com EDTA 17%. Os canais foram obturados pela técnica da condensação lateral com cones de guta percha e os cimentos: AH Plus, Epiphany SE ou RealSeal XT. As raízes foram armazenadas (100% de umidade, 37°C) por três vezes o tempo de endurecimento do cimento utilizado. Após este período, as raízes foram seccionadas para obtenção de dois slices (2 mm) de cada terço radicular. Um slices de cada terço foi submetido ao teste de push-out através de dispositivo mecânico MTS acoplado ao &mu;CT SkyScan 1174 (50kV, 80mA). Após o escaneamento inicial do slices, com resolução isotrópica de 13 &mu;m, filtro de 0.5 mm de Al e 360º de rotação, o teste mecânico foi iniciado até que ocorresse o deslocamento do material. Novo escaneamento foi realizado com os mesmos parâmetros iniciais, que determinou regiões de ruptura da massa obturadora em secções axiais. Os tipos de falhas foram avaliados por MCVL e classificadas em: adesivas, coesivas e mistas. Modelos 3D de elementos finitos foram gerados para os terços cervical, médio e apical, a partir de imagens de &mu;CT. No segundo slices de cada terço radicular, foi aferido o percentual de gaps do material obturador às paredes do canal radicular, por meio de MCVL e do programa OLS 4000. Os dados foram analisados por testes estatísticos paramétricos e não paramétricos (p<0,05). O cimento AH Plus [1,89 (1,01/2,39) MPa] apresentou maior resistência de união à dentina (p<0,001) quando comparado aos cimentos Epiphany SE [0,36 (0,29/0,44) MPa] e RealSeal XT [0,43 (0,32/0,54) MPa]. Para os cimentos AH Plus e RealSeal XT, os terços cervical e médio apresentaram maior resistência de união à dentina que o terço apical (p<0,001). As rupturas ocorreram nas margens da massa obturadora para o cimento AH Plus, enquanto os cimentos Epiphany SE e RealSeal XT tiveram este tipo de ruptura, bem como na própria massa obturadora. No cimento AH Plus, a interface de união mostrou maior concentração de tensões, que foram distribuídas principalmente na massa obturadora para os cimentos Epiphany SE e RealSeal XT. Houve predominância de falhas adesivas e mistas em todos os cimentos. Em relação ao percentual de gaps, o cimento AH Plus apresentou as menores médias (11,14% ± 4,03), com diferença estatisticamente significante (p<0,05) dos cimentos Epiphany SE (55,39% ± 13,46) e RealSeal XT (62,50% ± 6,72). O cimento à base de resina epóxica (AH Plus) apresentou a maior resistência de união à dentina e teve comportamento diferente em relação aos outros cimentos, quanto à ruptura da massa obturadora e distribuição de tensão interfacial. Além disso, o cimento AH Plus apresentou o menor percentual de gaps entre o material obturador e as paredes do canal radicular / The aim of this study was to evaluate the bond strength of epoxy resin- and methacrylate-based sealers to root dentin, using the material testing stage (MTS) coupled to a micro-computed tomography (&mu;CT) device and to qualitatively assess the root-filling mass rupture by &mu;CT images. Additional analyses were conducted using the 3D element finite method and confocal laser scanning microscopy (CLSM) to verify, respectively, the stress distribution and percentage of gaps on dentin filling material interfaces. Maxillary canine roots measuring 17 mm were subjected to biomechanical preparation with nickel-titanium rotary instruments under constant irrigation with 1% NaOCl and final irrigation with 17% EDTA. Canals were filled by the lateral condensation technique with gutta-percha cones and the following sealers: AH Plus, Epiphany SE or RealSeal XT. The roots were stored (100% humidity, 37 °C) for a period three times longer than the setting time required for each sealer and then sectioned transversally to obtain two 2-mm-thick slices from each root third. One slice of each third was subjected to the push-out test using the MTS coupled to the SkyScan 1174 &mu;CT (50 kV, 80 mA) with 13 &mu;m isotropic resolution, 0.5 mm Al filter and 360° rotation. After the initial scanning of the slice, the mechanical test was performed until material dislodgement occurred. A new scanning was performed using the same initial parameters. The axial sections obtained were used for qualitative evaluation of the root-filling mass rupture. Failure modes were assessed by CLSM and classified as adhesive, cohesive or mixed. 3D &mu;CT based finite element models were generated from cervical, middle and apical root thirds to simulate the push-out test. The second slice of each root third was used to assess the percentage of gaps between the filling material and the root canal walls, using CLSM with the aid of the OLS 4000 software. The data were analyzed by parametric and non-parametric tests (p<0.05). AH Plus presented higher bond strength [1.89 (1.01/2.39) MPa] to dentin (p<0.001) than Epiphany SE [0.36 (0.29/0.44) MPa] and RealSeal XT [0.43 (0.32/0.54) MPa]. For AH Plus and RealSeal XT sealers, the cervical and middle thirds showed higher bond strength to dentin than the apical third (p <0.001). The ruptures occurred in the margins of the root filling mass for AH Plus, while Epiphany SE and RealSeal XT had this type of rupture as well as in the root filling mass itself. AH Plus showed stress concentration on bond interface, while in Epiphany SE and RealSeal XT the stress was mainly distributed on the root-filling mass. Adhesive and mixed failures were the predominant fracture modes in all sealers. Regarding the percentage of gaps between the filling material and the root canal walls, AH Plus presented the lowest means (11.14%±4.03), differing significantly (p<0.05) from Epiphany SE (55.39%±13.46) and RealSeal XT (62.50%±6.72) sealers. The epoxy resin-based sealer (AH Plus) presented the highest bond strength to dentin, which had different behavior from other sealers regarding root-filling mass rupture and interfacial stress distribution. Moreover, AH Plus resulted in the lowest percentage of gaps between the material and the root canal walls

Page generated in 0.1056 seconds