Return to search

Análise energética do milho em sistema de plantio direto, em assentamento rural, Itaberá/SP

Made available in DSpace on 2014-06-11T19:24:42Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-02-03Bitstream added on 2014-06-13T19:31:34Z : No. of bitstreams: 1
santos_rr_me_botfca.pdf: 739634 bytes, checksum: 22dd4ee99538bf6df069fdde6891965e (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo deste trabalho foi analisar do ponto de vista energético o agroecossistema milho, em sistema de plantio direto, localizado na área III do projeto de assentamento de trabalhadores rurais Pirituba II, no município de Itaberá/SP. A análise energética quantificou todas as operações realizadas, juntamente com suas exigências físicas (quilogramas, litros, horas, metro, hectare, alqueire etc), os insumos utilizados e os grãos produzidos, classificando-os em seus respectivos fluxos, a partir da definição das entradas e saídas de energia, traduzindo-os em equivalentes energéticos e determinando, assim, a matriz energética do agroecossistema. Os índices calóricos utilizados foram os de eficiência cultural e energia cultural líquida. Os resultados desta pesquisa demonstraram a dependência do sistema de fontes de energia industrial, provindas de fertilizantes (44,42%) e agrotóxicos (18,71%), e de energia fóssil do óleo diesel (28,06%). Os valores energéticos, referentes aos tipos de energia direta e indireta, apresentaram grandezas distintas, sendo que a energia indireta (65,60%) representou quase o dobro da energia direta (34,40%) utilizada no sistema, significando que as fontes energéticas utilizadas encontram-se pouco equilibradas. A 2 eficiência cultural encontrada foi de 14,39, apontando que para cada unidade calórica aplicada no agroecossistema o retorno foi de 13,39 unidades e a energia cultural líquida atingiu 115.388,28 MJ x ha-1. Num segundo momento, os dados obtidos foram comparados aos dados publicados por Bueno (2002), que realizou sua pesquisa neste mesmo agroecossistema, ano agrícola e área, porém em duas glebas diferentes que empregavam o sistema de plantio convencional. Na comparação entre os estudos, as entradas culturais de ambos os sistemas foram energeticamente muito semelhantes com 8.619,73 MJ x ha-1 (plantio direto)... / The aim of this work was to proceed, from the energetic point of view, an analysis of a corn agroecosystem, on the direct planting, located at Pirituba II rural workers placement project, Área III, city of Itaberá/SP. The energetic analysis mesured all operations, together with its fisical demands (kilograms, liters, hours, meters, surface measures, etc), the inputs and produced grains, classifying them within their respective flux, based on the definition of energy inputs and outputs, converting them into energetic equivalents and, so, determining the energetic matrix of de agroecosystem. The caloric index used were cultural efficiency and cultural liquid energy. The results showed the dependence of the studied systems on the chemical energy sources, from fertilizers (44,42%), agrotoxics (18,71%), and diesel (28,06%). The energetic values of the direct and indirect energy showed a very big difference between them: indirect energy (65,60%) represented almost twice the direct energy (34,40%) used on the system, what means that the energy sources used in the system are not balanced. The cultural efficiency found was 14,39, pointing that for every caloric unity applied on the agroecosystem, the return was of 13,39 units and cultural liquid energy got to 115.388,28 MJ x ha-1. Later on, obtained data was compared to already existing data in Bueno 4 (2002), who researched corn agroecosystem, in the same agriculture period, at the same area, in two different gleba, with conventional planting system. Comparing both studies, the cultural inputs of both systems were energeticaly almost the same: 8.619,73 MJ x ha-1 (direct planting), e 8.783,78 MJ x ha-1 (convencional planting). The outputs had very different results: 124.008,01 e 79.118,38 MJ x ha-1, respectively. So, we had much more cultural liquid energy on the studied system: 115.388,28 MJ x ha-1, compared... (Complete abstract click electronic access below)

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/90582
Date03 February 2006
CreatorsSantos, Ricardo Rodrigues dos [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Simon, Elias José [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatviii, 70 f. : tabs.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0024 seconds