Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-01-09T11:36:05Z
No. of bitstreams: 1
brauliocesardeoliveira.pdf: 2150243 bytes, checksum: 62faa254539b7873aa1393d8cd8f1bf2 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2017-01-31T11:23:24Z (GMT) No. of bitstreams: 1
brauliocesardeoliveira.pdf: 2150243 bytes, checksum: 62faa254539b7873aa1393d8cd8f1bf2 (MD5) / Made available in DSpace on 2017-01-31T11:23:24Z (GMT). No. of bitstreams: 1
brauliocesardeoliveira.pdf: 2150243 bytes, checksum: 62faa254539b7873aa1393d8cd8f1bf2 (MD5)
Previous issue date: 2016-03-08 / O presente trabalho tem por objetivo apresentar uma metodologia para estimação de estados em sistemas de distribuição de energia elétrica. São utilizadas como variáveis de estado as correntes nos ramos. As medições são obtidas por meio de medições fasoriais sincronizadas(PhasorMeasurementUnits-PMUs),sendoqueostiposdemedidasadvindos desses equipamentos são as tensões nodais e as correntes nos ramos. A abordagem é trifásica, portanto representa as características próprias de um sistema de distribuição. A metodologia consiste em resolver um problema de otimização não linear cuja função objetivo associa o erro quadrático das medidas em relação aos estados estimados sujeito às restrições de carga das barras da rede que não possuem PMUs instaladas baseadas em estimativas de cargas obtidas para o instante “t-1”, partindo-se da premissa que em curtos intervalos de tempo a carga não sofre grandes variações, sendo esta em conjunto com a abordagem trifásica as principais contribuições deste trabalho. Outra contribuição do trabalho é a descentralização, com esta técnica pode-se dividir uma determinada rede em vários subsistemas que podem ser resolvidos de forma separada e independente. Isso torna o processo mais rápido do ponto de vista computacional além de permitir o uso do processamento paralelo, visto que já existe um paralelismo natural entre as tarefas que devem ser resolvidas. Outra vantagem da divisão em subsistemas reside no fato do monitoramento de áreas de interesse. Para utilizar a descentralização foi proposta uma alternativa de alocação de PMUs que consiste em posicionar duas unidades em cada ramificação do sistema, uma no começo e outra no final do trecho, procurando utilizar o menor número possível e que não comprometa a qualidade dos estados estimados. A resolução do problema de otimização é realizada através da implementação computacional do Método de Pontos Interiores com Barreira de Segurança (Safety Barrier Interior Point Method - SFTB - IPM) proposto na literatura especializada. As medidas das PMUs foram obtidas através de um Fluxo de Potência Trifásico via Injeção de Correntes (FPTIC). Foram realizadas diversas simulações variando-se o percentual da carga e os resultados obtidos foram comparados com outra metodologia existente na literatura e com os valores verdadeiros que foram obtidos através do FPTIC para as barras não monitoradas. Foram tambémcomparadosotempocomputacionalentreaexecuçãoserialeaexecuçãoutilizando o processamento paralelo. Os testes mostraram bons resultados o que torna a metodologia proposta aplicável na supervisão de sistemas de distribuição. / This work aims to present a methodology for static state estimation in electric power distribution systems. Branch currents are used as state variables. Measurements are obtained by means of Phasor Measurement Units (PMUs), in which voltage and current branches measurements are used. The approach is three-phase, thus represents the distribution system characteristics. The methodology consists of solving a nonlinear optimization problem minimizing a quadratic objective function associated with the estimated measurements and states subject to load constraints for the non monitored loads based on estimated load obtained from the ‘t-1’ instant, starting from the assumption that in short time intervals the load does not have large variations, which together with the the three-phase approach are the main contributions of this work. Another contribution of this work is the descentralided approach, with this assumption the network can be divided into several subnetworks that can be solved separately and independently. This speeds up the process of being solved from a computational point of view and allows the use of parallel processing, since there is already a natural parallelism among tasks to be solved. Another advantage of the division into subsystems is the fact that the monitoring areas of interest. With the aim of allowing the decentralization was proposed PMUs allocation strategy that consists of allocating two units for each lateral feeder, one at the beginning and one at the end, trying to use as little PMUs as possible in such a way that the quality of the estimated states are not compromised. The resolution of the optimization problem is done through a computer implementation of Interior Point Method with Security Barrier (SFTB - IPM) proposed in the literature. The PMUs measurements were emulated using a Three-PhasePowerFlowusingtheCurrentInjectionmethod(FPTIC).Severalsimulations were performed varying the load percentage and the results obtained were compared with other existing methodology in literature and also the true values that were obtained from the FPTIC to non monitored loads. The computational time using serial and parallel processing were also compared. Results show good results which makes the proposed methodology applicable in monitoring distribution systems.
Identifer | oai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/3141 |
Date | 08 March 2016 |
Creators | Oliveira, Bráulio César de |
Contributors | Pereira, José Luiz Rezende, Falcão, Djalma Mosqueira, Passos Filho, João Alberto, Garcia, Paulo Augusto Nepomuceno |
Publisher | Universidade Federal de Juiz de Fora (UFJF), Programa de Pós-graduação em Engenharia Elétrica, UFJF, Brasil, Faculdade de Engenharia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0036 seconds