Return to search

High resolution ultrasonic monitoring of muscle dynamics and novel approach to modelling

The presented work is concerned with the development and application of an ultrasonic detection scheme suitable for the monitoring of muscle dynamics with high temporal - down to 5 µs - and spatial resolution - down to 0.78 µm. A differential detection scheme has been developed to monitor the variations of the velocity of longitudinal polarized ultrasound waves travelling in contracting and relaxing muscle, compensating for variations of the path length by referencing to a frame. The observed time dependent variations of the time-of-flight of the ultrasonic waves caused by variations in the muscle and in addition by minor deformations of the enclosure are detected each separately and synchronously and are evaluated differentially. Beside of the detected increase of the speed of sound observed for contracted muscle with respect to the relaxed state of about 0.6%, the recovery time from maximum isometric contraction is quantified and relaxation processes are observed for the recovery phase following the isometric contraction. The developed ultrasonic calliper was employed to monitor both, the brain controlled and externally excited muscle dynamics with sampling intervals down to 10 ms synchronously with signals relating to the excitation. Monitored are the activation, hold, and relaxation phase for maximum voluntary isometric contraction of the gastrocnemius muscle. A so far not reported post tetanus overshoot and subsequent exponential recovery are observed. Both are attributed to the muscle as suggested by combined monitoring with EMG and are modelled with a lumped mechanical circuit containing an idealized bidirectional linear motor unit, ratchet, damper, and springs. Both, the rapid contraction and relaxation phases require a high order filter or alternatively a kernel filter, attributed to the nerve system as suggested by external electric stimulation. The respective response function is modelled by an electrical lumped circuit. Together with a reaction time and occasionally observed droops in the hold phase, both adjusted empirically, the monitored response is represented in close approximation by the combined electrical and mechanical lumped circuits. The respectively determined model parameters provide a refined evaluation scheme for the performance of monitored athletes. Valuable parameters relate to the latent period, the muscle response time, the activation and deactivation dynamics, a possible droop and other instabilities of the hold phase, and parameters characterizing the relaxation phase including the observed post tetanus overshoot and subsequent contraction. Monitored and modelled are also the different processes involved in active muscle dynamics including isotonic, isometric, and eccentric contraction or stretching. The developed technology provides time sequential observation of these processes and registration of their path in the extension and force parameter space. Under suitable conditions the closed-loop cycles of mind controlled human muscle movements proceed along characteristic lines coinciding with well identifiable elementary processes. The presentation of the monitored processes in the extension and force parameter space allows the determination of the mechanical energy expenditure for the observed different muscle actions. An elementary macroscopic mechanical model has been developed, suitable to express the basic features of the monitored muscle dynamics.

Identiferoai:union.ndltd.org:DRESDEN/oai:qucosa.de:bsz:15-qucosa-102502
Date11 January 2013
CreatorsMuhammad, Zakir Hossain
ContributorsUniversität Leipzig, Fakultät für Physik und Geowissenschaften, Prof. Dr. Grill Wolfgang, Prof. Dr. Radmacher Manfred, Prof. Dr. Käs Josef, Prof. Dr. Grundmann Marius, Prof. Dr. Haase Jürgen, Prof. Dr. Kremer Friedrich, Prof. Dr. Witt Maren
PublisherUniversitätsbibliothek Leipzig
Source SetsHochschulschriftenserver (HSSS) der SLUB Dresden
LanguageEnglish
Detected LanguageEnglish
Typedoc-type:doctoralThesis
Formatapplication/pdf, application/pdf, application/pdf, application/pdf, application/zip

Page generated in 0.0023 seconds