Return to search

Análise fotoelástica da distribuição de tensões em implantes dentais sob carga axial e não axial comparando-se implantes cônicos e cilíndricos e a topografia das roscas / Photoelastic analysis of stress distribution on dental implants under axial and non axial loads comparing cylindrical and conical implants and the thread topography

Orientador: Luciana Asprino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T14:53:17Z (GMT). No. of bitstreams: 1
RodriguesCougo_MiltonCristian_M.pdf: 1951044 bytes, checksum: ba8e67a871a041bcbdcef11db00eea5e (MD5)
Previous issue date: 2014 / Resumo: A perda óssea ao redor dos implantes dentários geralmente está associada à concentração das cargas mastigatórias na interface osso-implante e a propagação dessas tensões na crista do osso alveolar, acarretando uma diminuição na longevidade dos implantes. O objetivo deste estudo foi avaliar, comparativamente, in vitro, o efeito de diferentes desenhos do corpo e das roscas de implantes dentários, empregando a técnica experimental da fotoelasticidade. Para isto foram testados implantes Neodent® com interface protética Cone Morse, de 3,5mm de diâmetro e 13mm de comprimento, variando-se o desenho dos implantes e das roscas entre: corpo cônico com dupla rosca Alvim®, corpo cilíndrico e dupla rosca Titamax Ex® e corpo cônico com roscas duplas e progressivas Drive®. Realizou-se avaliação qualitativa da distribuição das tensões geradas por incidência de cargas axiais e não axiais de 0,5 Kg, assim como avaliação quantitativa da tensão nos terços cervicais, médios e apicais dos implantes, após incidência destas cargas. Os valores das médias de tensões cisalhantes máximas foram submetidos à análise de variância para dados com dois fatores de estudo (ANOVA 2-Way), seguidos pelo teste de Tukey para a comparação entre as médias. Com esta análise constatou-se que o grupo Alvim® apresentou maior concentração de tensões em relação aos outros grupos, comparando-se os pontos cervicais, quando submetido a carregamento axial obteve-se os valores médios de 16,05±5,75 Kgf e não axial de 25,03±4,16 Kgf, significativamente maiores que os outros grupos testados. Em relação aos pontos médio e apicais não houve uma diferença estatisticamente significante entre os grupos. Foi constatado que os implantes com corpo cônico e roscas duplas progressivas apresentam melhor distribuição das tensões / Abstract: Bone loss around dental implants is generally associated with concentration of masticatory loads on the implant-bone interface and the spread of such strains in the alveolar bone crest, resulting in a decrease in longevity of implants. The goal of this study is do an in vitro evaluation of the effect of different body designs and threaded of dental implants, using the experimental technique of photoelasticity. For this Neodent implants will be tested with Morse taper interface, diameter: 3.5 mm and length: 13 mm, varying the design of implants and implant threads: 1- tapered body with double thread Alvim ®; 2- cylindrical body and double thread Titamax Ex ®; 3- tapered body with progressive double threads Drive ®. Were conducted a qualitative evaluation of the stress distribution generated by incidence of non-axial and axial loads, as well as quantitative evaluation of tension in the cervical, middle and apical thirds of the implants after incidence of these charges. The average values of maximum shear stress were subjected to analysis of variance for data with two factors studied (2 - Way ANOVA) followed by Tukey test for comparison between means. With this analysis, the group Alvim ® showed statistically significant higher concentration of stresses than other groups, comparing cervical points. when subjected to axial loading was obtained the average values of 16.05 ± 5.75 Kgf and not axial 25.03 ± 4.16 kgf significantly higher than the other groups tested. Regarding the medium and apical points there was no statistically significant difference between the groups .Was found that the implants Drive® showed better stress distribution over the implants compared to implants of the other groups / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289610
Date04 April 2014
CreatorsRodrigues Cougo, Milton Cristian, 1985-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Asprino, Luciana, 1974-, Junior, Manoel Gomes Troia, Correr, Ana Rosa Costa
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format67 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds