Submitted by Elizabete Silva (elizabete.silva@ufes.br) on 2015-04-08T20:23:10Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Lilian Valadares Tose.pdf: 22786688 bytes, checksum: 4b658f7b5444bc01ea9bd4002e47455e (MD5) / Approved for entry into archive by Elizabete Silva (elizabete.silva@ufes.br) on 2015-04-14T19:21:33Z (GMT) No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Lilian Valadares Tose.pdf: 22786688 bytes, checksum: 4b658f7b5444bc01ea9bd4002e47455e (MD5) / Made available in DSpace on 2015-04-14T19:21:33Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Lilian Valadares Tose.pdf: 22786688 bytes, checksum: 4b658f7b5444bc01ea9bd4002e47455e (MD5)
Previous issue date: 2014-12 / A análise de hidrocarbonetos por técnicas de ionização a pressão atmosférica ou ambiente continua a ser um desafio na espectrometria de massas. Normalmente, a ionização ocorre através de mecanismos de protonação e desprotonação. Para isso, as moléculas de interesse devem apresentar um grupo básico ou ácido que proporcionem a geração de íons [M+H]+ ou [M-H]-. Para superar essa limitação, um
método analítico simples, fácil, rápido e poderoso foi desenvolvido com sucesso, adaptado a partir da literatura, para ionizar saturado e insaturado, linear, ramificado, e hidrocarbonetos cíclicos, bem como hidrocarbonetos poliaromáticos e heteroaromáticos presentes em frações de hidrocarbonetos e de misturas de parafina/petróleo bruto utilizando ionização química à pressão atmosférica (APCI), favorecido pela utilização de solventes alifáticos de cadeia curta em um espectrômetro de massas FT-ICR. Entre os reagentes alifáticos estudados, isoctano proporcionou os melhores resultados quando comparado com outros solventes. Além disso, foram estudados outros interferentes do processo de ionização, como
concentração da solução injetada e misturas parafina/óleo, que influenciavam desde o perfil dos espectros até as principais classes de compostos identificados. O método torna possível a ionização de hidrocarbonetos pela produção de íons [M -H]+ sem ocorrência de fragmentação. / The analysis of hydrocarbon using atmospheric or ambient ionization techniques still remains a challenge in mass spectrometry. Traditionally, the ionization occurs via protonation or deprotonation. The molecules of interest must have a basic or acidic group to generated [M + H]+ or [M - H]- ions. To overcome
such limitation, it is proposed a simple, easy, fast and powerful analytical methodology to ionize saturated (linear and branched), unsaturated, and cyclic hydrocarbons as well as polyaromatic and heteroaromatic hydrocarbonsby atmospheric pressure chemical ionization (APCI) using small hydrocarbons as
reagents in a FT-ICR mass spectrometer. These molecules may be present in hydrocarbon fraction samples and paraffin/crude oil blends. Among the APCI hydrocarbon reagents studied, isooctane provided the best results when compared to pentane, hexane, cyclohexane and heptane. The method renders the ionization of
hydrocarbons to yield [M – H]+ ions with no associated fragmentation using nitrogen as sheath gas.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufes.br:10/1348 |
Date | 12 December 2014 |
Creators | Tose, Lilian Valadares |
Contributors | Vaz, Boniek Gontijo, Romão, Wanderson |
Publisher | Mestrado em Química, Programa de Pós-Graduação em Química |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | text |
Source | reponame:Repositório Institucional da UFES, instname:Universidade Federal do Espírito Santo, instacron:UFES |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0023 seconds