Return to search

Análise de faltas em sistemas elétricos de potência considerando dados incertos / Fault analysis in electric power systems considering uncertain data

Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-03-13T20:53:05Z
No. of bitstreams: 1
rodolfooliveiraruback.pdf: 2343401 bytes, checksum: 8f9848927e2f5b7628d4e279716725d4 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-16T12:53:44Z (GMT) No. of bitstreams: 1
rodolfooliveiraruback.pdf: 2343401 bytes, checksum: 8f9848927e2f5b7628d4e279716725d4 (MD5) / Made available in DSpace on 2017-03-16T12:53:44Z (GMT). No. of bitstreams: 1
rodolfooliveiraruback.pdf: 2343401 bytes, checksum: 8f9848927e2f5b7628d4e279716725d4 (MD5)
Previous issue date: 2016-08-02 / A análise de faltas, também conhecida como análise de curto-circuito, é imprescindível tanto no âmbito de planejamento quanto na operação de um sistema elétrico de potência. Essa análise é geralmente realizada de forma determinística, para dados valores em um instante de tempo. Contudo, o sistema de potência é dinâmico e seus parâmetros estão sujeitos a variações. Desta forma, a utilização do modelo determinístico se torna inviável face as inúmeras simulações necessárias no sentido de representar todas as possíveis combinações das variações envolvidas no problema. Este trabalho propõe incorporar a matemática intervalar na análise de faltas, de modo a possibilitar a representação das incertezas dos parâmetros na forma de intervalos e, por conseguinte, gerar resultados intervalares de tensão e corrente na barra de falta, refletindo tais incertezas. Portanto, o objetivo básico é modelar e implementar um método para análise de faltas intervalar. Dois sistemas testes, um de 5 barras e outro de 14 barras, são utilizados para gerar as tensões e correntes intervalares no ponto de falta. Tais resultados são validados pela simulação de Monte Carlo. / Fault Analysis, also known as short-circuit analysis, is essential both in the planning and the operation of an electric power system. This analysis is usually done in a deterministic way for data values in an instant of time. However, the power system is dynamic and his parameters are subject to variations. Thus, using the deterministic model has become inaccurate face the numerous simulations required to represent all the combinations of possibles variations involved in the problem. This paper proposes to incorporate interval mathematics to fault analysis, in a way to represent the parameter uncertainties as intervals and therefore generate interval results of voltage and current in the short-circuited bar, reflecting these uncertainties. Therefore, the basic objective is to model and implement a method for interval fault analysis. Two test systems, one with 5 bars and the other with 14 bars, are used to generate voltages and currents interval in the fault point. These results are validated by Monte Carlo simulation.

Identiferoai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/3657
Date02 August 2016
CreatorsRuback, Rodolfo Oliveira
ContributorsCosta, Vander Menengoy da, Schilling, Marcus Theodor, Passos Filho, João Alberto
PublisherUniversidade Federal de Juiz de Fora (UFJF), Programa de Pós-graduação em Engenharia Elétrica, UFJF, Brasil, Faculdade de Engenharia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0016 seconds