Return to search

Análise da resistência mecânica e fractográfica de placas de titânio do sistema 1,5mm e dois métodos de fixação em fraturas simuladas em corpo de hemimandíbula de alumínio / Mechanical and fractographic analysis of 1,5mm titanium platesin two methods of fixation in simulated body fractures of aluminum hemimandibles

Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T17:35:55Z (GMT). No. of bitstreams: 1
Rodrigues_DanilloCosta_M.pdf: 1685806 bytes, checksum: 0e90fd8fb32a562bcf7161f1f78bfab7 (MD5)
Previous issue date: 2013 / Resumo: O presente estudo teve como propósito analisar a resistência mecânica de duas marcas de fixação do sistema 1,5mm através de teste mecânico de carregamento linear em dois métodos de fixação em modelos de hemimandíbulas de alumínio com fraturas simuladas e realizar análise fractográfica. Foi realizada a confecção de quatro estruturas de alumínio semelhantes a hemimandíbula, sendo utilizada duas hemimandíbulas para cada grupo de estudo. As mesmas foram fixadas com placas e parafusos das marcas Tóride® e Traumec®. No grupo I foi empregada uma placa reta de titânio de quatro furos na zona de compressão e outra na zona de tensão mandíbular; e no grupo II, foi empregada apenas uma placa reta de quatro furos na zona neutra. Para os testes mecânicos, foi utilizada a máquina para ensaio universal mecânica Instron® modelo 4411 até ocorrer a falha total do sistema de fixação (fratura da placa). Em seguida, as amostras foram submetidas a análises fractográficas das superfícies fraturadas com microscópio eletrônico de varredura FEI®. Foi aplicada a Análise de Variância (ANOVA) dois fatores e o teste de Tukey com significância de 5%. A fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01) em relação ao grupo de apenas uma placa, independente da marca comercial. A marca Tóride® apresentou média de deslocamento de pico maior que as placas Traumec® quando avaliadas nos grupos com uma placa e extensão de carga no deslocamento de 5mm. As amostras romperam por sobrecarga dúctil, por falha mecânica caracterizada por dano alveolar / Abstract: The purpose of this study was to analyze the mechanical strength of two brands of 1.5 mm system fixation through mechanical linear load test in two fixation methods in aluminum hemimandibles with simulated body fractures and perform fractographic analysis of the samples. Four aluminum structures similar to hemimandibles were fabricated with a linear sectioning simulating a fracture of mandibular body and two hemimandibles were used in each group for posterior fixation with plates and screws with two national brands: Toride® and Traumec®. The group I was fixed with a straight titanium plate with four holes in the compression zone and another one in the tension zone. Group II was fixed with a straight plate with four holes in the neutral zone. For mechanical testing, a universal mechanical testing Instron ® Model 4411 was used and the test was made until final failure of the system (fracture plate). Then, the samples were submitted to fractographic analysis through a scanning electron microscope FEI ®. A analysis of variance (ANOVA) Two-way and Tukey test with 5% significance (?= .05) were applied for statistical analysis. The fixation method with two straight plates showed a higher load resistance (p<0.01) when compared to the group of only one plate, regardless of the brand. The brand Toride® showed an average of peak displacement higher than Traumec® when the groups with only one plate with the extension of 5mm were evaluated. All the samples fractured by ductile overload, characterized by alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288764
Date23 August 2018
CreatorsRodrigues, Danillo Costa, 1981-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Moreira, Roger William Fernandes, 1971-, Araujo, Marcelo Marotta, Sverzut, Alexander Tadeu
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format42 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0086 seconds