Return to search

A sobrecarga aguda cardÃaca advinda de fÃstula aorto-caval retarda o esvaziamento gÃstrico de lÃquidos em ratos acordados. / The overload acute cardiac after aortocaval fistula delays the gastric emptying of liquids in awake rats.

CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Tendo em vista que o comportamento motor do trato gastrointestinal parece ter intima relaÃÃo com a atividade do sistema cardiovascular, decidimos verificar se a redistribuiÃÃo do volume sanguÃneo atravÃs de fistula aorto-caval com agulhas de calibres (21, 23 ou 26G) afeta a motilidade do trato gastrintestinal em ratos acordados. Ratos machos albinos (230 a 280g) foram divididos em grupos falso-operado (FO) ou com fÃstula designados (F), alÃm disso, tiveram grupos fÃstula+sangria (FS), fÃstula+vagotomia (FV) bem como fÃstula+esplancnotomia (FE), todos estudados com 24 horas apÃs a confecÃÃo da fistula com agulha (21G). Os parÃmetros hemodinÃmicos de pressÃo arterial mÃdia (PAM), freqÃÃncia cardÃaca (FC), e pressÃo venosa central (PVC) foram monitorados continuamente e o dÃbito cardÃaco (DC) determinado por termo-diluiÃÃo. ApÃs os procedimentos cirÃrgicos os ratos FO e os (F) tiveram os parÃmetros hemodinÃmicos e o esvaziamento gÃstrico (EG) estudados nos tempos pÃs-prandial (10, 20 ou 30min.). A PA dos ratos (F) tiveram valores inferiores (p < 0,05) quando comparados aos FO (116,3  3,5 vs 101,3  3,3mmHg). Por outro lado, nos ratos (F) houve aumento (p < 0,05) nos valores da PVC (1,9  0,4 vs 5,8  0,6cmH2O) da FC (365,0  7,0 vs 417,0  7,0bpm) e do DC (119,9  9,6 vs 172  5,3ml/min) quando comparados aos ratos FO. Em relaÃÃo ao FO ocorreu uma retenÃÃo gÃstrica nos ratos (F) nos tempos pÃs-prandial 10, 20 e 30min (45,6 Â3,6 vs 57,5  2,1%; 36,4  2,7 vs 50,5  3,3 % e 33,3  2,7 vs 44,7  3,0 %, respectivamente). Os ratos do grupo (FS), apresentaram valores de (EG) inferiores aos animais (F) (36,5  3,2 vs 50,5  3,3%, p<0,05), mas similares aos FO (36,4  2,7%). Em relaÃÃo à vagotomia (FV), a mesma reverteu o retarde no (EG) induzido pela FÃstula (F) (40,4  2,3 vs 50,5  3,3%), em contrapartida, os ratos submetidos a esplancnotomia (FE) nÃo apresentaram diferenÃas com os (F) (50,5  3,3 e 50,1  1,4%). AlÃm do mais, nÃo foi encontrada participaÃÃo da secreÃÃo Ãcida no retarde do (EG) apÃs fÃstula. Portanto, a sobrecarga cardÃaca advinda de fÃstula arteriovenosa com agulhas de calibre (21, 23 ou 26G) alÃm de promover alteraÃÃes nos parÃmetros hemodinÃmicos, induz retarde no (EG) e interfere no trÃnsito intestinal de lÃquidos em ratos acordados. Tal retarde no (EG) inclusive foi abolido apÃs sangria ou vagotomia subdiafragmÃtica prÃvias, mas nÃo havendo alteraÃÃo apÃs esplancnotomia. / In view that the behaviour of gastrointestinal tract seems to have intimate relationship with the activity of the cardiovascular system, we decided to verify whether the redistribution of blood volume through fistula aorto-caval with sizes of needles (21, 23 or 26G) affect the motility of the gastrointestinal tract in rats awaked. Male albino rats (230 to 280g) were divided into groups false-operated (FO) or designated with fistula (F), moreover, had groups fistula + bleeding (FS), fistula + vagotomy (FV) and fistula + esplancnotomy (FE), all with studied 24 hours after preparation of the fistula with needle (21G). Hemodynamic parameters of mean arterial pressure (MAP), heart rate (HR), central venous pressure (CVP) were monitored continuously and cardiac output (CO) determined by term-dilution. After the surgical procedures the rats FO and (F) had the hemodynamic parameters and gastric emptying (GE) studied in the time post-prandial (10, 20 or 30min.). The MAP of rats (F) had lower values (p <0.05) when compared to FO (116.3  3.5 vs. 101.3  3.3 mmHg). Moreover, in rats (F) increased (p <0.05) the values of CVP when compared to rats FO (1.9  0.4 vs 5.8  0.6 cmH2O), HR (365.0  7.0 vs 417.0  7.0 bpm) and the CO (119.9  9.6 vs 172  5.3 ml / min). In relation the rats the FO was a gastric retention increased in (F) in the time post-prandial 10, 20 and 30min (45.6  3.6 vs 57.5  2.1%; 36.4  2.7 vs 50.5  3.3% and 33.3  2.7 vs 44.7  3.0%, respectively). The rats of the group (FS), showed values of (GE) lower than the animals (F) (36.5  3.2 vs 50.5  3.3%, p <0.05) but similar to FO ( 36.4  2.7%). The vagotomy (FV), it reversed the delay in the (GE) induced by fistula (F) (40.4  2.3 vs 50.5  3.3%), in contrast, the rats undergoing esplancnotomy (FE) showed no differences in comparation with the (F) (50.5  3.3 and 50.1  1.4%). Moreover, was not found involvement of acid secretion in the delays of the (GE) after fistula. Therefore, the overload heart arisen from arteriovenous fistula with needles, size (21, 23 or 26G) to promote changes in hemodynamic parameters, leads decreases the (GE) and interfere in the intestinal transit of liquids in rats awaked. This delay in the (GE) was also abolished after bleeding or prior the subdiaphragmatic vagotomy, but no change after esplancnotomy.

Identiferoai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:2439
Date15 February 2008
CreatorsMoisÃs Tolentino Bento da Silva
ContributorsArmÃnio Aguiar dos Santos, Josà Ronaldo Vasconcelos da GraÃa, AntÃnio Aldo Melo Filho
PublisherUniversidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Farmacologia, UFC, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0085 seconds