Análise das microdeformações geradas ao redor de implantes de hexágono externo sob a aplicação de cargas verticais em pilares microunit retos e angulados /

Orientador: Renato Sussumu Nishioka / Banca: Rubens Nisie Tango / Banca: Luís Gustavo de Oliveira Vasconcellos / Resumo: O objetivo desse estudo foi avaliar in vitro, por meio da extensometria, a distribuição de tensões ao redor de implantes com conexão hexagonal externa diante diferentes situações de inclinação dos pilares protéticos. Foram utilizados 2 blocos de poliuretano, no primeiro bloco foram instalados 3 implantes paralelos entre si e inclinados em 17º, e no segundo bloco foram instalados 3 implantes paralelos entre si e perpendiculares a superfície. Houve o assentamento dos respectivos pilares protéticos microunit para correção das angulações. Coifas plásticas foram instaladas e unidas a 10 estruturas em resina acrílica para cada grupo. Na superfície do bloco foram colados 4 extensômetros tangenciando cada implante. Carregamentos estáticos verticais de 30 kg com intervalos de 10 segundos sobre os 3 parafusos de retenção da estrutura. Os dados obtidos pelos extensômetros sob 3 repetições foram submetidos ao teste ANOVA. Obtidas média de 294,32 ± 284,44 με ao redor dos implantes com pilares retos e média de 300,74 ± 238,85 με para o grupo com pilares angulados. Não houve diferença significativa entre os grupos, não observamos diferença de microdeformação entre os diferentes pontos de aplicação de carga. Concluiu-se que a utilização de implantes inclinados em 17º e sua correção por meio de pilares angulados apresenta resultados de microdeformação semelhantes a implantes perpendicularmente posicionados / Abstract: The aim of this study was to evaluate in vitro, by means of strain gauge analysis, the stress distribution around implants with external hexagon connection facing different tilt situations. Two blocks of polyurethane were used, in first block the 3 implants were installed parallel to each other and inclined at 17 degrees, and the second block 3 implants were installed parallel to each other and perpendicular to the surface, then their abutments were connected to correct angulation, being screwed with a torque of 20 N.cm. Plastic hoods were installed and united to 10 acrylic resin structures for each group. In the block area, four strain gauges were glued tangent to each implant. Vertical static loads of 30 kg with 10 second intervals over three retaining screws of the structure. The data obtained by the strain under three replicates were subjected to ANOVA. Average of 294.32 ± 284.44 με were recorded around implants positioned axially and average of 300.74 ± 238.85 με for the group with tilted implants. There was no significant difference between the group with implants straight and the group with tilted implants, no significant difference in microstrain between different points of load application. As conclusion, we observed the use of tilted implants in 17 degrees presents results of microstrain similar to axial implants / Mestre

Identiferoai:union.ndltd.org:UNESP/oai:www.athena.biblioteca.unesp.br:UEP01-000823040
Date January 2014
CreatorsLouzada, Frederico Freire.
ContributorsUniversidade Estadual Paulista "Julio de Mesquita Filho" Instituto de Ciência e Tecnologia (Campus de São José dos Campos).
PublisherSão José dos Campos,
Source SetsUniversidade Estadual Paulista
LanguagePortuguese, Portuguese, Texto em português; resumos em português e inglês
Detected LanguageEnglish
Typetext
Format80 f. :
RelationSistema requerido: Adobe Acrobat Reader

Page generated in 0.0908 seconds