Return to search

Otimização de metodologia de análise de ácido graxo trans (C18:1 9t) por eletroferese capilar em amostras alimentícias

Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-05-10T18:25:16Z
No. of bitstreams: 1
patriciamendoncadecastro.pdf: 1709438 bytes, checksum: 8a160d714175f2a01b3cebc4f7a10f7b (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-11T13:28:35Z (GMT) No. of bitstreams: 1
patriciamendoncadecastro.pdf: 1709438 bytes, checksum: 8a160d714175f2a01b3cebc4f7a10f7b (MD5) / Made available in DSpace on 2017-05-11T13:28:35Z (GMT). No. of bitstreams: 1
patriciamendoncadecastro.pdf: 1709438 bytes, checksum: 8a160d714175f2a01b3cebc4f7a10f7b (MD5)
Previous issue date: 2010-02-22 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Foi desenvolvido um método alternativo para determinação do teor de trans total expresso em ácido elaídico utilizando eletroforese capilar de zona (CZE), com detecção indireta no UV em 224 nm e tempo de análise em torno de 8 minutos. O eletrólito de corrida otimizado é composto por 15,0 mmol L-1 KH2PO4 / Na2HPO4 (pH em torno de 6,8); Brij 35 8,0 mmol L-1, SDBS 4,0 mmol L-1, n-octanol 1,5% v/v, acetonitrila 45% v/v e metanol 8% v/v. A separação do par crítico C18:1 9t/C18:1 9c alcançou a linha base do eletroferograma com resolução acima do mínimo desejado de 1,50. Utilizou-se espectroscopia Raman para estudo sobre a composição do tampão fosfato utilizado no eletrólito e planejamento de experimentos 32 para determinação dos níveis ótimos de Brij 35 e n-octanol. Logo, após a otimização do sistema de eletrólito, realizou-se uma curva de calibração utilizando C15:0 como padrão interno e, após a verificar que não houve falta de ajuste no modelo proposto, o fator de resposta (Rf) foi calculado e aplicado na quantificação das amostras de gordura vegetal hidrogenada, margarina, requeijão e biscoito recheado por CE. O método otimizado por CE foi comparado com a metodologia oficial por cromatografia gasosa da American Oil Chemists’ Society (AOCS) para amostra de gordura vegetal hidrogenada. Os métodos foram comparados usando o teste t-student para amostras independentes com réplicas autênticas de seis e os resultados obtidos não apresentaram diferença significativa para o intervalo de confiança de 95% estimado. Os resultados alcançados foram satisfatórios, indicando que o método otimizado por eletroforese capilar pode ser usado para determinação do teor total de trans em diversas amostras alimentícias apresentando como vantagens: menor tempo de análise, ausência de passos de derivatização no preparo da amostra, uso de colunas não-específicas e baixo custo. / A different method for determination of total trans fatty acids expressed as elaidic acid by capillary zone electrophoresis (CZE) under indirect UV detection at 224 nm within an analysis time of 8 min was developed. The optimized running electrolyte includes 15.0 mmol L-1 KH2PO4/Na2HPO4 buffer (pH ∼ 6,8), 4.0 mmol L-1 SDBS, 8.0 mmol L-1 Brij 35, 45% v/v ACN, 8% v/v methanol and 1.5% v/v n-octanol. Baseline separation of the critical pair C18:1-9t / C18-9cis with a resolution higher than 1.5 was achieved. The optimum capillary electrophoresis (CE) conditions for the background electrolyte were established with the support of Raman spectroscopy and experiments of a 32 factorial design were used to better level of Brij 35 and noctanol determination. Following optimization electrolyte system was made calibration curve using C15:0 as the internal standard and, after certification where no lack of fit within proposed model the response factor (RF) was calculated and applied to total trans fatty acid (TTFA) analysis in a hydrogenated vegetable fat (HVF), margarine, spreadable cheese and strawberry cookies samples by CE. The CZE method was compared with the American Oil Chemists’ Society (AOCS) official method by gas chromatography (GC) to hydrogenated vegetable fat samples using independent sample t-student test for six genuine replicates and no significant difference was found within 95% confidence interval. The results obtained were satisfactory, indicating that the optimized methodology by CE can be useful for TTFA analysis in different matrix foods presenting as advantages short analysis time, no derivatization step in sample preparation, no specific separation columns and low cost.

Identiferoai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/4233
Date22 February 2010
CreatorsCastro, Patrícia Mendonça de
ContributorsOliveira, Marcone Augusto Leal de, Micke, Gustavo Amadeu, Silva, Julio Cesar Jose da
PublisherUniversidade Federal de Juiz de Fora (UFJF), Programa de Pós-graduação em Química, UFJF, Brasil, ICE – Instituto de Ciências Exatas
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF
Rightsinfo:eu-repo/semantics/openAccess