Conforto ambiental em uma residência semiaberta com cobertura verde / Thermal confort in a residence built as a veranda with green roof

Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-22T02:21:00Z (GMT). No. of bitstreams: 1
Almeida_CarlaMatheusde_M.pdf: 11189524 bytes, checksum: a7fa919aa9c79e98af0575bc7bf36bb9 (MD5)
Previous issue date: 2013 / Resumo: Com a rápida urbanização, tem havido um aumento enorme de população e construções nas cidades. A alta concentração de prédios desencadeia muitas questões ambientais, como o efeito de ilhas de calor; que é agravado principalmente pela perda de áreas verdes no ambiente urbano (WONG et al., 2003). O alto consumo de energia para aquecimento e resfriamento de edificações é um dos maiores problemas do setor de energia e tem um impacto ambiental importante (JIMÉNEZ et al., 2010). A cobertura verde é uma boa estratégia para a redução do uso de energia, pois o calor externo é transmitido em menor quantidade e mais lentamente para o ambiente. Além da cobertura verde, a ventilação natural influencia positivamente no controle do conforto dos ambientes. A varanda constitui uma local agradável ambientalmente para a utilização nos países de clima tropical, pois possui uma cobertura para proteger dos raios solares diretos, permite a ventilação natural e ainda favorece a ligação com o entorno. Esta pesquisa tem como meta voltar-se para o conforto ambiental de forma passiva ao analisar o conforto ambiental de uma residência semiaberta na cidade de Atibaia, SP, construída em forma de varanda, com cobertura verde. A análise do conforto foi feita através de: medições in loco das variáveis ambientais, cálculo do Physiological Equivalent Temperature (PET) ensaia em túnel de vento e comparação dos resultados obtidos nessa simulação com aqueles obtidos nas medições in loco, visando verificar qual a real melhoria do conforto ambiental nessa área semiaberta. As medições in loco foram feitas no período outono e inverno de 2011 e verão de 2012. A partir dos resultados, pode-se inferir que, em relação à temperatura ambiente, apesar da temperatura superficial da cobertura verde ter uma atenuação de ate 9ºC em relação à da cobertura cerâmica, a combinação da cobertura verde com a cobertura cerâmica nessa área semiaberta proporciona uma atenuação da temperatura ambiente externa, de aproximadamente 2,5ºC graus. O calculo do PET mostrou que a área semiaberta melhora o grau de sensação de conforto. A análise da ventilação natural, feita através do ensaio em túnel de vento, mostrou que esse modo de implantação se faz eficiente para a diminuição da velocidade excessiva do vento na área semiaberta. O modelo de varanda com cobertura verde se mostrou uma boa forma para habitação para essa região / Abstract: With rapid urbanization, there has been a huge increase in population and buildings in cities. The high concentration of buildings triggers many environmental issues, such as the heat island effect, which is especially aggravated by the loss of green areas in urban environment (WONG et al., 2003). The high energy consumption for heating and cooling of buildings is one of the greatest problems of the energy sector and has a significant environmental impact (JIMÉNEZ et al., 2010). The green roof is a good strategy for reducing energy use, for the external heat is transmitted in less quantity and more slowly to the environment. Besides the green roof, natural ventilation positively influences in the control of the comfort of environments. The veranda, widely used in tropical countries, is a pleasant place, because it has a cover to protect from direct sunlight, allows natural ventilation and favors the connection with the surroundings. This research analyses the environmental comfort of a semi-open residence in the city of Atibaia, SP, built as a veranda, using green roof. The analysis of comfort was made through: local measurements of environmental variables, physiological Equivalent Temperature (PET) wind tunnel simulation and comparison between the results of wind speed obtained in the local measurements and the wind tunnel simulation, to identify what is the real improvement of thermal comfort in this semi-open area. The in site measurements were made during the autumn and winter of 2011 and summer of 2012. From the results, it could be inferred that, in relation to temperature, although the surface temperature of the green cover showed an attenuation of up to 9 ° C when compared to the tile roof, the combination of green roof with tile roof in this semiopen area provides a temperature attenuation of approximately 2.5 ° C degrees. The PET analyses showed that the semi-open area improves the level of comfort sensation. Regarding natural ventilation, the results showed that this mode of projecting was effective to reduce the excessive wind speed in the semi-open area / Mestrado / Arquitetura, Tecnologia e Cidade / Mestra em Arquitetura, Tecnologia e Cidade

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258592
Date22 August 2018
CreatorsAlmeida, Carla Matheus de
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Labaki, Lucila Chebel, 1943-, Lomardo, Louise Land Bittencourt, Bernardi, Nubia
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format82 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess