• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • 2
  • Tagged with
  • 73
  • 73
  • 60
  • 33
  • 29
  • 27
  • 24
  • 20
  • 19
  • 17
  • 16
  • 16
  • 15
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do potencial de arrefecimento de edifícios através da ventilação natural

Verdelho, Sara Isabel Carvalho January 2008 (has links)
Tese de mestrado. Construção de Edifícios. Faculdade de Engenharia. Universidade do Porto. 2008
2

Sistemas de ventilação natural e mistos em edifícios de habitação

Amaral, Manuel António Pinto da Silva January 2008 (has links)
Tese de doutoramento. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2008
3

Ventilação natural na construção civil: análise de alternativas para implantação de sistemas

Spinelli, Rodrigo 20 August 2015 (has links)
Submitted by FERNANDA DA SILVA VON PORSTER (fdsvporster@univates.br) on 2016-04-12T19:49:22Z No. of bitstreams: 3 license_text: 22064 bytes, checksum: ef48816a10f2d45f2e2fee2f478e2faf (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) 2015RodrigoSpinelli.pdf: 9322349 bytes, checksum: 3464489aab5898a028b17d30c3e31c59 (MD5) / Approved for entry into archive by Ana Paula Lisboa Monteiro (monteiro@univates.br) on 2016-04-14T21:18:45Z (GMT) No. of bitstreams: 3 license_text: 22064 bytes, checksum: ef48816a10f2d45f2e2fee2f478e2faf (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) 2015RodrigoSpinelli.pdf: 9322349 bytes, checksum: 3464489aab5898a028b17d30c3e31c59 (MD5) / Made available in DSpace on 2016-04-14T21:18:45Z (GMT). No. of bitstreams: 3 license_text: 22064 bytes, checksum: ef48816a10f2d45f2e2fee2f478e2faf (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) 2015RodrigoSpinelli.pdf: 9322349 bytes, checksum: 3464489aab5898a028b17d30c3e31c59 (MD5) / Nos últimos anos tem se ampliada a preocupação com o planejamento adequado da construção civil e o aproveitamento das características climáticas do local onde será executada uma edificação. Com o problema energético surgido nas últimas décadas, os sistemas de climatização artificial, um dos elementos que mais demandam a utilização de energia elétrica, demonstram a necessidade de serem repensados. O objetivo da pesquisa foi de avaliar a viabilidade de utilização de um sistema de climatização natural, com capacidade de resfriamento do ar captado, em protótipos localizados na área de atuação de clima subtropical. Foram executados quatro protótipos com sistemas de ventilação natural, diferentes entre si, porém com materialidade similar a executada comercialmente em larga escala. A pesquisa exploratória desenvolveu-se a partir da medição de dados em quatro protótipos executados para o estudo, localizados na cidade de Lajeado/RS. Foi possível concluir que os sistemas possuem um limite de eficiência, e que para atender de forma adequada padrões de conforto, dependem da análise da influência do entorno próximo (edificações, vegetação, relevo, etc.), análise da utilização de outros elementos de isolamento térmico, elementos construtivos e de climatização natural para se atingir temperatura adequada no interior das edificações para se alcançar níveis de conforto do ambiente construído. / In recent years there has been an increasing concern for the proper planning of construction and the optimal use of climate characteristics of the site where a construction is built. With the emergence of the energy issue in the last few decades, the artificial air conditioning ventilation systems, one of the elements that require the use of electricity, point that needs a rethinking. The purpose this study was to assess the feasibility of using a natural ventilation/cooling system with the capacity of cooling captured air in prototypes located in subtropical climate areas. Four prototypes were built with natural ventilation systems, one different from the other, though all with the same material which was also the one used commercially on a large scale. This exploratory research was based on measuring data of prototypes developed for the study, which were made in the city of Lajeado/RS (Southern Brazil). It was concluded that the systems have a limited efficiency and to meet adequately standards of comfort depend on the analysis of the influence of the immediate surroundings (buildings , vegetation , relief, etc.) , analysis of the use of other insulating elements thermal, structural elements and natural cooling to achieve adequate temperature inside the buildings to achieve comfort levels of the built environment.
4

Impacto energético de ventilação mecânica e recuperação de calor em edifícios residenciais em Portugal

Silva, Fernando José Pinto da January 2008 (has links)
Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2008
5

Aplicação do método de Monte Carlo em simulações higrotérmicas de edifícios.

Fonte, Pedro Duarte Pereira Carvalhido Ribeiro da January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2010
6

Desempenho da qualidade do ar em estudos de caso de ambientes hospitalares no contexto climático de Brasília – DF

Aguiar, João Renato Carneiro de 15 September 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-12-13T19:13:41Z No. of bitstreams: 1 2017_JoãoRenatoCarneirodeAguiar.pdf: 9426890 bytes, checksum: 54a5a7b556bd833299a84edfd6f99c45 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-02-20T20:48:38Z (GMT) No. of bitstreams: 1 2017_JoãoRenatoCarneirodeAguiar.pdf: 9426890 bytes, checksum: 54a5a7b556bd833299a84edfd6f99c45 (MD5) / Made available in DSpace on 2018-02-20T20:48:38Z (GMT). No. of bitstreams: 1 2017_JoãoRenatoCarneirodeAguiar.pdf: 9426890 bytes, checksum: 54a5a7b556bd833299a84edfd6f99c45 (MD5) Previous issue date: 2018-02-20 / Estudos demonstram os efeitos negativos das altas concentrações de partículas indesejadas no ar para a saúde humana. Normas vigentes da área de saúde preconizam a utilização de equipamentos artificiais para manter a qualidade do ar interno nos ambientes hospitalares, em detrimento de soluções passivas de ventilação. Neste sentido, a presente dissertação aborda o tema da ventilação natural em ambientes de saúde, com o objetivo principal de avaliar a renovação do ar em ambientes hospitalares no contexto climático de Brasília por meio de simulações computacionais. Como estudos de caso foram estudados 5 ambientes hospitalares de Brasília: o Hospital de Base do Distrito Federal, Hospital da Criança de Brasília, Hospital Sarah Centro, Hospital Sarah Lago e Hospital de Apoio de Brasília. A pesquisa se estruturou a partir da revisão bibliográfica com o uso das normas e legislações específicas; coleta de informações referente aos estudos de caso escolhidos; métodos para a definição da velocidade dos ventos predominantes e, por fim, a realização da simulação pelo processo computacional CFD (Computacional Fluid Dynamics – CFD Autodesk 2015) para analisar o potencial da ventilação natural nos ambientes hospitalares estudados. Os parâmetros para definição da velocidade do vento foram fornecidos pelas normais climatológicas (INMET), pela ficha bioclimática e pela fórmula matemática que avalia condicionantes do terreno e altura das aberturas. Os resultados da pesquisa apontam que o uso da ventilação natural nos ambientes é eficaz na maioria dos casos, sobretudo quando são associados a boa qualidade do ar externo e uma boa análise das condicionantes do entorno (que envolve direção dos ventos predominantes e análise de barreiras urbanas), assim sendo suficiente para promover uma boa qualidade do ar interna. / Studies demonstrate the negative effects of high concentrations of unwanted particles in the air for the human health. Currents health standards recommend the use of artificial equipment to maintain indoor air quality in hospital environments, in detriment of passive ventilations solutions. In this sense, the present dissertation aims to disseminate the topic of natural ventilation in health environments, with the main objective of evaluating the air renewal in the hospitals in the climatic context of Brasília by means of computational simulations. The case studies were 5 hospitals environments in Brasília: The Hospital de Base do Distrito Federal, Hospital da Criança de Brasília, Hospital Sarah Centro, Hospital Sarah Lago and Hospital de Apoio de Brasília. The research was structured from the bibliographical review with the use of specific norms and legislation, collection of information regarding the selected case studies, methods for definition of prevailing wind velocity and, finally a simulation performance for the CFD (Computational Fluid Dynamics – CFD Autodesk 2015) process to analyze the potential of natural ventilation in the hospitals studied. The parameters for definition the wind speed is provided by normal climatological (INMET), by bioclimatic chart and by mathematical formula that evaluates terrain conditions and height of the openings. The results of the research indicated that the use of natural ventilation in the health environments is effective in the most cases, especially when good external air quality is associated with a good analysis of the environmental conditions factors (involving predominant winds directions and analysis of urbans barriers), thus being sufficient to promote a good indoor air quality.
7

Diagrama de ventilação natural : ferramenta de análise do potencial da ventilação natural no estudo preliminar de projeto

Sales, Gustavo de Luna 11 March 2016 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2016. / Submitted by Camila Duarte (camiladias@bce.unb.br) on 2016-07-20T16:28:11Z No. of bitstreams: 1 2016_GustavodeLunaSales.pdf: 6698120 bytes, checksum: 0e96c1b5bde43be2b8976e3584d413ad (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-02-23T14:50:54Z (GMT) No. of bitstreams: 1 2016_GustavodeLunaSales.pdf: 6698120 bytes, checksum: 0e96c1b5bde43be2b8976e3584d413ad (MD5) / Made available in DSpace on 2017-02-23T14:50:54Z (GMT). No. of bitstreams: 1 2016_GustavodeLunaSales.pdf: 6698120 bytes, checksum: 0e96c1b5bde43be2b8976e3584d413ad (MD5) / A presente tese aborda o desenvolvimento do Diagrama de Ventilação Natural (DVN) – ferramenta de análise do potencial da ventilação natural, para favorecer a Qualidade Interna do Ar (QIA) e o Conforto Térmico Passivo (CTP) em projetos de habitações. Parte-se da hipótese de que é possível desenvolver uma ferramenta que proporcione uma análise mais simples, amigável e rápida em comparação com as atuais ferramentas disponíveis, e que seja aplicável durante as primeiras etapas do processo de projetação – mais especificamente, na etapa do Estudo Preliminar (EP). Para tanto, foram levantados na bibliografia sobre o tema os principais fatores externos e internos ao projeto que influenciam o potencial da ventilação natural em termos de QIA e o CTP. Posteriormente foram levantados os parâmetros legais mínimos exigidos pelos Códigos de Edificações e Normas Técnicas referentes à ventilação natural que, juntamente com os fatores externos e internos de projeto, foram transformados em variáveis a serem analisadas pelo DVN. Por fim, foram analisados os principais modelos que atualmente estão disponíveis para a análise da ventilação natural no projeto de arquitetura – modelos analíticos e empíricos, modelos em escala, modelo multizona e de zona, modelos computacionais de dinâmica dos fluidos. Essa análise identificou as principais deficiências das ferramentas/modelos atuais em termos de aplicação durante a etapa de Estudo Preliminar de Projeto – sendo essas: custo de aplicação, nível de habilidade técnica exigido do usuário, e interface pouco amigável. Assim, para suprir as deficiências apontadas, foi identificado que a ferramenta a ser desenvolvida deveria ser fundamentada nos princípios dos modelos gráficos – que visam justamente à simplificação do problema a ser estudado, a análise das principais variáveis influentes e a obtenção de um diagnóstico/resultado estimado por meio da combinação das variáveis identificadas. Após a estruturação do DVN, foi desenvolvida a ferramenta com linguagem simples, amigável e acessível gratuitamente na rede mundial de computadores. O DVN possibilita a quantificação do potencial da ventilação natural em favorecer a QIA e o CTP, fornece o número de renovações de ar por hora estimado para os ambientes de quarto, sala, cozinha e banheiro, além de informar ao usuário quais os aspectos que o EP cumpre em termos normativos/legais e quais as diretrizes para a melhoria de possíveis problemas. / This thesis describes the development of Natural Ventilation Diagram (NVD) - an analysis tool of the potential of natural ventilation to provide the Indoor Air Quality and Passive Thermal Comfort in the design of residential buildings. It starts with the hypothesis that it is possible develop a tool that provides more simple, user friendly, and faster analysis in comparison with the current available tools - and that is applicable during the first stages of the design process. Have been raised in the literature the major internal and external factors that influence the potential of natural ventilation associated with IAQ and PTC. Afterwards have been identified the minimum legal standards required by the Building Codes and Technical Standards relating to natural ventilation. The legal parameters and external and internal factors were transformed into variables that the user can analyze by the NVD. Finally, were analyzed the main models that are currently available for the analysis of natural ventilation in architectural design – empirical and analytical models, scale models, multizonal and zonal models, computacional computational fluid dynamics models. This analysis identified the main weaknesses of the tools / current models in terms of application for the Preliminary Design stage process - related to the cost of implementation, technical skill level required of the user, and unfriendly interface. Therefore, to fulfill the identified deficiencies, it was identified that the tool to be developed should be based on the principles of graphical models. The graphics models aim at simplification of the problem to be studied, the analysis of main influential variables and obtaining a diagnostic/result estimated by the combination of the identified variables. After structuring of NVD, it was developed the tool with simple language, friendly and available free on the World Wide Web. The NVD enable quantification of natural ventilation potential, provides an estimation of the number of air change per hour for rooms, living room, kitchen and bathroom. As well as inform the user which aspects meets in regulatory / legal terms and what the guidelines for the improvement of potential problems. / En esta tesis se describe el desarrollo del Diagrama de Ventilación Natural (DVN) - una herramienta de análisis del potencial de ventilación natural para promover la Calidad del Aire Interior (CAI) y el Confort Térmico Pasivo (CTP) en proyectos de viviendas. La posibilidad de desarrollar una herramienta que proporciona un análisis simple de usar y rápido de usuario, en comparación con las herramientas actuales disponibles, y que es aplicable durante las primeras etapas del proceso de projetação es la hipótesis inicial. En un primer momento ha planteado en la literatura sobre el tema de los principales factores externos e internos que influyen en la ventilación potencial del proyecto. Después de los estándares legales mínimos aumentaron requeridos por los códigos de construcción y normas técnicas relativas a la ventilación natural. Todos estos parámetros planteados fueron transformadas en variables para ser analizados por la herramienta propuesta. Por último, los principales modelos que están actualmente disponibles se analizaron para el análisis de la ventilación natural en el diseño arquitectónico - modelos analíticos y empíricos, modelos a escala, multi-zona y el modelo de zona, los modelos informáticos de dinámica de fluidos. Este análisis identifica las principales deficiencias de las / los modelos actuales herramientas en términos de aplicación durante la etapa de diseño preliminar del estudio - a saber: el costo de aplicación, nivel de habilidad técnica requerida del usuario, y la interfaz poco amigable. Para satisfacer las deficiencias identificadas, se identificó que la herramienta que se desarrollen deben estar basadas en los principios de los modelos gráficos. Después de estructuración de lo DVN, se desarrolló la herramienta con un lenguaje sencillo, amable y disponible gratuitamente en la World Wide Web. Lo que permite la cuantificación de la potencial de la ventilación natural en la calidad del aire favor y confort térmico; proporciona el número de renovaciones de aire por hora para la sala de estar, cocina y baño, así como informar al usuario qué aspectos se reúne en términos normativos / legales y cuáles son las pautas para la mejora de los problemas potenciales.
8

Rugosidade e porosidade do tecido urbano como critérios de análise qualitativa da ventilação natural em cidades litorâneas

Costa Filho, Amando Candeira 01 February 2017 (has links)
Submitted by Marta Toyoda (1144061@mackenzie.br) on 2017-05-12T20:18:37Z No. of bitstreams: 2 Amando Candeira Costa Filho.pdf: 17131427 bytes, checksum: 924d06531366bd57d3a3435736e29e0d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Paola Damato (repositorio@mackenzie.br) on 2017-05-16T14:35:39Z (GMT) No. of bitstreams: 2 Amando Candeira Costa Filho.pdf: 17131427 bytes, checksum: 924d06531366bd57d3a3435736e29e0d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-05-16T14:35:39Z (GMT). No. of bitstreams: 2 Amando Candeira Costa Filho.pdf: 17131427 bytes, checksum: 924d06531366bd57d3a3435736e29e0d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-01 / There is a close interaction between urban planning, city morphology and climate. In order to create adequate environments for human needs, the design of cities must incorporate strategies adapted to the climate at its various scales. Respect for local and global climatic conditions can increase the health of city dwellers by promoting environmental comfort and social life (ZHAO, 2011). Among the bioclimatic attributes related to the urban form, the roughness and the porosity of the urban fabric, have significant interference in the behavior of the natural ventilation. The objective of this thesis is to verify and improve qualitative methods of analysis of the behavior of natural ventilation in coastal cities of hot and humid climate, from the bioclimatizing attributes of height rugosity and distance porosity of the urban fabric. The methods adopted in this research followed experimental and exploratory procedures. In the first moment, qualitative analyzes were carried out related to the bioclimatic attributes of the urban form and its influence on natural ventilation. Each addressed attribute generated a score that was organized into survey cards and the results were spatially exposed on roughness and porosity maps. The three areas of the northern coast of the city of Fortaleza were evaluated and quantitative analyzes of computational simulations were carried out to compare the results obtained in the roughness and porosity maps developed in the qualitative analysis. After the analysis of the results, it was evident that the evaluation of the height, roughness and the porosity of the distance, proved to be valid as a qualitative criterion of the natural ventilation. The different soil occupation situations that were studied had repercussions on the results and the formal attributes were efficient for the analysis of the behavior of the winds. There are recommendations for the improvement of the method: its application in other urban and climatic situations, the insertion of other environmental variables in the analyzes such as the geometry of the sun and other possible bioclimatizing attributes related to natural ventilation. / Há uma estreita interação entre planejamento urbano, morfologia da cidade e o clima. Para criar ambientes adequados às necessidades humanas o desenho das cidades deve incorporar estratégias adaptadas ao clima em suas diversas escalas. O respeito as condições climáticas, local e global, pode aumentar a saúde dos habitantes de uma cidade, promovendo conforto ambiental e vida social (ZHAO, 2011). Dentre os atributos bioclimáticos relacionados à forma urbana, a rugosidade e a porosidade do tecido urbano, têm interferência significativa no comportamento da ventilação natural. É objetivo desta tese verificar e aprimorar métodos qualitativos de análise do comportamento da ventilação natural em cidades litorâneas de clima quente e úmido com apoio nos atributos bioclimatizantes de rugosidade de altura e porosidade de afastamento do tecido urbano. Os métodos adotados nesta pesquisa seguiram procedimentos experimentais e exploratórios. No primeiro momento, foram realizadas análises qualitativas relacionadas aos atributos bioclimatizantes da forma urbana e sua influência na ventilação natural. Cada atributo abordado gerou uma pontuação que foi organizada em fichas de levantamento e os resultados expostos espacialmente em mapas de rugosidade e porosidade. As três áreas avaliadas do litoral norte da cidade de Fortaleza, passaram por análises quantitativas resultantes de simulações computacionais para comparação dos resultados alcançados nos mapas de rugosidade e porosidade desenvolvidos na análise qualitativa. Concluídas as análises dos resultados ficou evidente que avaliação da rugosidade de altura e da porosidade de afastamento, se mostrou válida como critério qualitativo da ventilação natural. As diferentes situações de ocupação do solo estudadas repercutiram nos resultados e, os atributos formais levantados, se revelaram eficientes para análise do comportamento dos ventos. Ficam como recomendações para o aprimoramento do método: sua aplicação em outras situações urbanas e climáticas, a inserção de outras variáveis ambientais nas análises como a geometria da insolação e outros possíveis atributos bioclimatizantes relacionados a ventilação natural.
9

Análise do desempenho térmico de edificações residenciais ventiladas naturalmente : NBR 15.575 e ASHRAE 55 / Analysis of thermal performance of free-running residential buildings : NBR 15.575 e ASHRAE 55

Silveira, Francisco Massucci, 1983- 05 June 2014 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T07:50:03Z (GMT). No. of bitstreams: 1 Silveira_FranciscoMassucci_M.pdf: 9492485 bytes, checksum: f3520eb8830cb5c6373fb8dc37cb631c (MD5) Previous issue date: 2014 / Resumo: A obtenção de ambientes internos confortáveis termicamente é um dos aspectos fundamentais na obtenção de um edifício de qualidade. Por vezes, para se atingir este objetivo consome-se quantidades significativas de energia em sistemas de condicionamento ambiente. É preciso ressaltar que grande parte da população não possui recursos para aquisição e manutenção destes sistemas, ficando, portanto, exposta ao comportamento térmico de suas edificações. Assim, é fundamental compreender, como e sob quais circunstâncias, ocupantes de uma edificação consideram-na confortável de modo a avaliar e propor soluções que permitam a geração de conforto ao menor custo. A obtenção do conforto através do uso exclusivo da climatização artificial vem se mostrando uma prática dispendiosa, dando lugar a introdução da ventilação natural e outras práticas de resfriamento passivo. A aplicação destes instrumentos tem ganhado força recentemente, sendo referenciado em normativos internacionais que regulam sobre o tema. A partir de 2004, a norma ASHRAE 55 Environmental Conditions for Human Occupancy adotou uma abordagem de análise denominada modelo adaptativo: uma metodologia opcional, proposta para avaliação do desempenho térmico em edifícios ventilados naturalmente. O método utiliza-se da temperatura operativa - que correlaciona efeitos da temperatura de bulbo seco, temperatura radiante e velocidade do ar - como principal fator indicador de conforto. Além disso, a norma correlaciona a faixa de temperatura de conforto à ocorrência de temperaturas externas, possibilitando a comparação entre edificações situadas em climas distintos. Neste contexto, esta pesquisa destina-se à verificação do desempenho térmico de uma edificação unifamiliar através da análise do conforto térmico, levando-se em consideração aspectos de uso, ocupação e ventilação natural, utilizando-se a abordagem adaptativa proposta pela norma ASHRAE 55/2013. O método utilizado compreende a simulação computacional de uma edificação habitacional unifamiliar de 63m², por meio da utilização do software EnergyPlus. O modelo simulado não possui sistema de condicionamento ativo e a ventilação natural foi simulada pelo EnergyPlus, através do algoritmo denominado AirflowNetwork, um modelo de ventilação por rede, onde são estimados fluxos de massa através de aberturas e perda de carga térmica em decorrência de diferenças de pressão nas aberturas do edifício. A condição para abertura das janelas é dependente da temperatura externa e de uma temperatura máxima interna arbitrada, o que permite utilizar a ventilação natural como ferramenta de resfriamento passivo. O trabalho compreende a análise de diferentes variáveis de projeto, divididas em cinco grupos, a partir de um caso base inicial. Os grupos de análise definidos são: componentes de fachada; componentes de cobertura; orientação da edificação; absortância de componentes de fachada e temperatura de setpoint para ventilação. Para cada grupo foram estipulados diferentes casos, compreendendo aspectos e elementos convencionais do mercado de construção habitacional. Todos os casos foram analisados para as condições climáticas de Campinas-SP, Curitiba-PR e Natal-RN a partir de modelo adaptativo de conforto pela norma ASHRAE 55/2013, e comparados ainda a resultados obtidos através do método simplificado e simulado, presente na norma NBR15575/2013. Os resultados apontam as melhores práticas construtivas, demonstrando substancial importância do modelo adaptativo na verificação do conforto térmico em projeto para edificações destinadas à habitação de interesse social / Abstract: Achieve thermal comfortable indoor environments is a key aspect to obtaining a quality building. Sometimes, in order to achieve it, significant amount of energy in conditioning systems is consumed. It should be emphasized that a large part of the population does not have resources for acquisition and maintenance of these systems, being exposed to passive thermal behavior of their buildings. Thus, it is essential to understand how and under what circumstances, occupants of a building consider it comfortable to assess and propose solutions that generate comfort at a lower cost. Obtaining comfort through exclusive use conditioning systems has proved an expensive practice, leading to the introduction of natural ventilation and other passive cooling practices. The application of these instruments has excelled recently, being referenced in international standards. In 2004, the ASHRAE 55 Environmental Conditions for Human Occupancy adopted a method called adaptive model analysis: an optional methodology, proposed for evaluation on thermal performance in naturally ventilated buildings. The method uses the operative temperature - which correlates the effects of dry bulb temperature, mean radiant temperature and air velocity - as the main indicator of comfort. Moreover, the standard correlates the range of comfort to the occurrence of outdoor temperatures, enabling comparison between buildings located at different climates conditions. Under this context, this study aimed to verify the thermal performance of a dwelling through the analysis of thermal comfort, including aspects of use, occupancy and natural ventilation. The method comprises the computer simulation of a 63m² single-family housing construction, using the software EnergyPlus. The simulated model has no active conditioning system. Natural ventilation was simulated with EnergyPlus through the algorithm AirflowNetwork, a model of ventilation network, where mass flows through openings and loss of thermal load, due to pressure differences in building, are estimated. The condition for opening window depends on external temperature and a setpoint temperature, which supposes the use of natural ventilation only as daytime passive cooling tool. The work includes the analysis of different design variables, divided into five groups, defined from an initial base case. The analysis groups are: masonry components; roofing components; orientation; absorptance and setpoint temperature for ventilation. For each group were prescribed different situations, including aspects and elements of conventional housing construction market. All cases were analyzed for the climatic conditions of Campinas - SP, Curitiba - PR and Natal - RN for adaptive comfort model by ASHRAE 55/2013, yet compared to results obtained by the simplified method and simulated method present in NBR15575/2013. The results indicate the best construction practices, demonstrating substantial importance of adaptive model to assess thermal comfort of dwellings / Mestrado / Arquitetura, Tecnologia e Cidade / Mestre em Arquitetura, Tecnologia e Cidade
10

Estudo da eficiência para a ventilação natural dos sheds em hospitais da Rede Sarah / Study of the efficiency of natural ventilation of sheds Sarah network in Hospitals

Camargo, Renata Martinho de 19 August 2018 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-19T06:39:40Z (GMT). No. of bitstreams: 1 Camargo_RenataMartinhode_M.pdf: 4984279 bytes, checksum: 362dc581c34f0a018e1778f146c62eab (MD5) Previous issue date: 2011 / Resumo: A ventilação natural em regiões tropicais é uma eficiente estratégia de projeto para a obtenção de conforto térmico e para a redução do consumo de energia. O aproveitamento dos recursos naturais e das condicionantes do clima melhora a integração do edifício com o entorno e a obtenção do conforto através de sistemas passivos de condicionamento. Os efeitos do vento em um edifício são analisados através da dinâmica dos fluidos computacional (CFD, Computational Fluid Dynamics) ou de estudos em túnel de vento. É importante quantificar variáveis como: velocidade, pressão, temperatura e coeficiente de pressão. Os Hospitais da Rede Sarah Kubistchek, projetados por João Filgueiras Lima, Lelé, são considerados bons exemplos de arquitetura bioclimática, devido as suas soluções passivas de conforto, como a utilização dos sheds, que promovem a iluminação e a ventilação natural. Esses hospitais foram construídos em várias capitais brasileiras, com diferentes climas. Este trabalho tem como objetivo avaliar a eficiência da ventilação natural dos Hospitais Sarah localizados nas cidades de Brasília e Belém. Essas cidades foram escolhidas devido às características climáticas bastante diferenciadas - clima quente seco e quente úmido. Os sheds no hospital de Belém funcionam como extratores de vento, ao passo que no hospital de Brasília Lago Norte foram projetados como captadores de vento. A análise é feita através de ensaios em túnel de vento de camada limite atmosférica. Os testes incluem medições de velocidade do ar e pressão em vários pontos dentro e fora dos edifícios. O hospital de Belém é analisado em sua implantação real e na situação em que o vento predominante incide perpendicularmente à fachada. Os resultados mostram que, tanto o conjunto de aberturas e o sistema de sheds do hospital de Belém, quanto a sua implantação, proporcionaram maior velocidade do ar nos ambientes internos do que o hospital Brasília Lago Norte. Os resultados dos coeficientes de pressão permitiram confirmar que, para os dois hospitais analisados, o projeto de ventilação natural aproveita as áreas de maior pressão para posicionamento das aberturas de entrada e saída de ar / Abstract: Natural ventilation in tropical regions is an efficient design strategy for achieving thermal comfort and reducing energy consumption. The utilization of natural resources and climate conditions improves integration of the building with its surroundings and allows comfort conditions through passive systems of conditioning. The effects of wind on a building are analyzed using computational fluid dynamics (CFD, Computational Fluid Dynamics) or wind tunnel studies. It is important to quantify variables such as speed, pressure, temperature and pressure coefficient. The Sarah Kubitschek Network hospital, designed by João Filgueiras Lima, Lelé, are considered good examples of bioclimatic architecture, due to the passive solutions for comfort, such as the use of sheds, which provide natural lighting and ventilation. These hospitals were built in several Brazilian cities with different climates. This study aims to evaluate the efficiency of natural ventilation of Sarah hospitals located in the cities of Brasília and Belém. These cities were chosen because of the different climate characteristics of the two cities - mild dry and hot humid. The sheds in the hospital of Belem act as wind extractors, while those in in Brasilia Lago Norte hospital was designed as a means of wind catchers. The analysis is done through testing in atmospheric boundary layer wind tunnel. The tests include measurements of air velocity and pressure at several points inside and outside of buildings. The Belém hospital is analyzed in its actual implantation and in the situation where the prevailing incident wind is perpendicular to the facade. The results show that both the number of openings and the shed system in the hospital in Belém, as well as its implantation, provided a higher air speed in indoor environments than the hospital Brasília Lago Norte. The results for the pressure coefficients allow to confirm that for both hospitals studied, the design of natural ventilation takes advantage of the higher pressure areas for positioning of the income and exit of air / Mestrado / Arquitetura e Construção / Mestre em Engenharia Civil

Page generated in 0.0948 seconds