Return to search

Índice geométrico na determinação da perda de carga localizada em conexão de emissores sobre tubos de polietileno de pequenos diâmetros / Geometrical Index in the determination of head losses located in connection of emitters on polyethylene pipes of small diameters

O procedimento de dimensionamento de uma linha lateral de microirrigação necessita avaliar com precisão as perdas de carga distribuídas na tubulação e as perdas de carga localizadas nas inserções dos emissores com os tubos. Estas perdas localizadas podem ser significativas quando comparadas com as perdas de carga totais, devido ao grande número de emissores instalados ao longo da linha lateral. Este trabalho reporta os resultados de um experimento sobre perda de carga distribuída, fator de atrito e perda de carga localizada em conexões de emissores &#34;on-line&#34; em tubos de polietileno de pequeno diâmetro. Foram utilizados cinco tubos com diâmetros internos de 10,0 mm, 13,0 mm, 16,3 mm, 17,4 mm e 19,7 mm. O experimento foi conduzido para números de Reynolds no intervalo de 5000 a 68000, obtidos pela variação da vazão nos tubos, a uma temperatura média da água de 20 &#177; 2 &#176;C. Os resultados foram analisados e concluiu-se que o fator de atrito f da equação de Darcy-Weisbach pode ser estimado com c = 0,300 e m = 0,25. A equação de Blasius com c = 0,316 e m = 0,25 mostrou-se conservadora na estimativa do fator de atrito, porém esse fato não constitui limitação para sua utilização em projetos de microirrigação. As análises mostraram que as duas equações proporcionam estimativas de f com pequeno desvio médio (5,1%). Para um dado conjunto tubo-conexão o coeficiente de carga cinética (KL) foi praticamente independente do número de Reynolds, para R>20000, sugerindo que cada conjunto tubo-conexão pode ser caracterizado por um valor médio de KL. Para desenvolver um procedimento de estimativa de KL, a geometria da conexão entre o emissor e o tubo foi caracterizada por um índice de obstrução IO, que depende da razão (r) entre a área da seção transversal do tubo, onde o conector está localizado, e a área da seção transversal do tubo fora do conector. Uma função potência foi ajustada aos pares experimentais (IO, KL). A seleção do modelo é consistente com o fenômeno físico uma vez que KL = 0 para r = 1 (nenhuma obstrução dentro do tubo). Para 5000<R68000 a relação foi KL = 1,23 (IO)0,51 com R2 = 0,9556 e erro padrão do ajuste igual a 0,04245. As diferenças entre os valores de KL estimados e observados são normalmente distribuídas. / Microirrigation lateral design procedure needs to accuratel evaluation of both the pipe head losses and the local losses that are due to the protrusion of emitter barbs into the flow. These local losses, in fact (in relation to the high number of emitters located along the line) can become significant compared to the overall energy loss. On this paper, the results of an experimental study on the pipe head losses, friction factor and head local losses for small-diameters polyethylene pipes are reported. The experiment was carried out using a range of Reynolds number between 5000 to 68000, obtained by varying discharge at 20 &#177; 2 &#176;C water temperature, with a internal diameter pipes of 10,0 mm, 13,0 mm, 16,3 mm, 17,4 mm and 19,7 mm. According to the results analysis and experimental conditions the friction factor (f) of the Darcy-Weisbach equation can be estimated with c = 0,300 and m = 0,25. The Blasius equation (c = 0,316 and m = 0,25) gives a conservative estimative of f, although this fact is non restrictive for microirrigationsystem design. The analysis shows that both the Blasius and the adjusted equation parameters allow accurate friction factor estimate, characterized by low mean error (5,1%). For a given pipeconnection system, the fraction KL of kinetic head was practically independent of the Reynolds number, for R>20000, which suggested that each system can be characterized by the mean value of KL. To derive an estimating procedure of KL, the geometry of the connection between the emitter and the pipe was characterized by the obstruction index IO, which is dependent on the ratio (r) between the pipe cross-section area corresponding to the section in which the emitter is located, and the pipe cross-section area. A power relationship was then fitted to the experimental IO, KL data pairs. The selection form of thr relationship is consistent with the physical phenomenon since it estimates KL = 0 for r = 1 (no obstruction into the pipe). For 5000<R<68000 the relationship was KL = 1,23 (IO)0,51 with R2 = 0,9556 and standard fit error equal to 0,04245. The differences between KL observed values and the calculated ones are normally distributed.

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-21082007-115147
Date01 August 2007
CreatorsCardoso, Gabriel Greco de Guimarães
ContributorsFrizzone, Jose Antonio
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguageEnglish
TypeDissertação de Mestrado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.0023 seconds