Submitted by Verônica Esteves (vevenesteves@gmail.com) on 2017-09-28T19:33:45Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação Flávio Gasperini.pdf: 2318649 bytes, checksum: af9486980e507779dbd5975709e84b4d (MD5) / Approved for entry into archive by Verônica Esteves (vevenesteves@gmail.com) on 2017-09-28T19:34:10Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação Flávio Gasperini.pdf: 2318649 bytes, checksum: af9486980e507779dbd5975709e84b4d (MD5) / Made available in DSpace on 2017-09-28T19:34:10Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação Flávio Gasperini.pdf: 2318649 bytes, checksum: af9486980e507779dbd5975709e84b4d (MD5)
Previous issue date: 2010 / Consultório / Os defeitos críticos ósseos oriundos de trauma, tumores ou doenças degenerativas determinam um desafio no campo da Ortopedia, visto que a reconstrução cirúrgica se faz necessária através de enxertos ósseos. Apesar de os enxertos autógenos serem considerados um “padrão ouro”, as cerâmicas sintéticas a base de Hidroxiapatita (HA) são materiais muito promissores, devido às suas inerentes características biocompatíveis. A possibilidade de diminuição do tamanho das partículas em escala nanométrica e o advento da hidroxiapatita nanoestruturada podem melhorar a remodelação óssea. O objetivo deste estudo foi avaliar a resposta tecidual e a biocompatibilidade de esferas de HA produzidas a partir de partículas nanométricas em comparação às esferas de HA produzidas a partir de partículas micrométricas, ambas no estado sinterizado e não-sinterizado (Sem tratamento térmico), bem como seu potencial de degradação e osteogênese, em relação ao grupo controle (coágulo). Os biomateriais foram implantados em defeitos ósseos nas tíbias de 12 coelhos da raça Nova Zelândia (Oryctolagus cuniculus), pesando entre 2000g e 3500g. As esferas (425-600 μm) tiveram as propriedades físicas e químicas caracterizadas por DRX, FT-IR, MEV e foram também submetidas ao teste de dissolução. Os animais foram divididos randomicamente em cinco grupos: Grupo 1 (Controle) – coágulo sanguíneo; Grupo 2 – HA Sinterizada; Grupo 3 – HA Sem tratamento térmico; Grupo 4 – NanoHA Sinterizada; e Grupo 5 – Sem tratamento térmico. Os animais foram mortos 7 e 28 dias após a cirurgia e as amostras submetidas ao processamento histológico. As esferas não-tratadas eram menos cristalinas que as sinterizadas (DRX e FT-IR), sendo mais solúveis in vitro (teste de dissolução). In vivo, a nanoHA e a HA, ambas sem tratamento térmico, dissolveram e promoveram maior formação de tecido ósseo em relação às esferas sinterizadas. Concluiu-se que os materiais se mostraram biocompatíveis e osteocondutores, porém a neoformação óssea foi mais acentuada nos grupos da HA e nanoHA não-tratadas termicamente. / Bone critical defects from trauma, tumors or degenerative diseases prescribe a challenge in orthopedics, since surgical reconstruction is required by bone grafts. Although autografts are considered a gold standard, the synthetic ceramics based on hydroxyapatite (HA) are promising materials due to their inherent characteristics biocompatible. The possibility of decreasing the size of the particles at the nanometer scale and the advent of nanostructured hydroxyapatite may improve bone remodeling. The aim of this study was to evaluate the tissue response and biocompatibility of HA spheres shape made from nano-sized particles compared to the HA spheres made from micro-sized particles, both in sintered and non-heat treated as well as its potential for degradation and osteogenesis compared to control group (clot). The spheres (425-600 μm) had the physical and chemical properties characterized by XRD, FT-IR, SEM and were also subjected to dissolution test and the biomaterials were implanted in bone defects on 12 New Zealand rabbit’s tibiae (Oryctolagus cuniculus), weighing between 2000g and 3500g. The animals were randomly divided into five groups: Group 1 (Control) - blood clot, Group 2 - sintered HA, Group 3 - non-heat treated HA, Group 4 - sintered NanoHA and Group 5 - non-heat treated NanoHA. Animals were euthanized at 7 and 28 days after surgery and samples submitted to histological procedings. The non-heat treated had a lower cristallinity that the sintered materials (XRD and FT-IR), being more soluble in vitro (dissolution tests). In vivo, NanoHA and HA, both non-treated, degraded and promoted greater bone formation in relation to the sintered spheres. In conclusion, materials showed biocompatibility and osteoconduction, but the bone formation was more accentuated in the non-heat treated groups.
Identifer | oai:union.ndltd.org:IBICT/oai:https://app.uff.br/riuff:1/4717 |
Date | January 2010 |
Creators | Gasperini, Flávio Marcos |
Contributors | Lugon, Jocemir Ronaldo, Tude, Elena Mavropoulos Oliveira, Lima, Inayá Corrêa Barbosa, Maia, Mõnica Diuana Calasans, Granjeiro, José Mauro |
Publisher | Universidade Federal Fluminense, Niterói |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFF, instname:Universidade Federal Fluminense, instacron:UFF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0027 seconds