Return to search

Influence in the biomechanicals of different metal alloys and prosthetic abutments in the prosthesis partial fixed of three elements = Influência de diferentes ligas metálicas e pilares protéticos na biomecânica de próteses parciais fixas de três elementos / Influência de diferentes ligas metálicas e pilares protéticos na biomecânica de próteses parciais fixas de três elementos

Orientador: Guilherme Elias Pessanha Henriques / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T15:50:42Z (GMT). No. of bitstreams: 1
Luthi_LeonardoFlores_D.pdf: 11662191 bytes, checksum: a2fdd8f7955f803f55d8b5d7bcd0f0bc (MD5)
Previous issue date: 2014 / Resumo: Pilares tipo UCLA calináveis são bem aceitos no meio odontológico por permitirem manipulação em laboratório a custo reduzido e a individualização das próteses em função de cada paciente. Porém quando utilizados para sobrefundição possuem prerrogativas de menores custos que os pilares pré-fabricados e melhor adaptação que os calcináveis. Assim o objetivo, deste estudo foi avaliar a influência na indução de tensão aos implantes por meio de extensometria utilizando próteses confeccionadas com pilares UCLA sobrefundidos em diferentes ligas metálicas. O presente estudo apresenta dois capítulos, sendo que o primeiro aborda as diferenças entre os pilares calcináveis e os sobrefundidos e suas respectivas ligas. Para tanto, foram confeccionados 40 infraestruturas metálicas sobre implantes simulando próteses parciais fixas de 3 elementos utilizando pilares UCLAs convencionais e pilares UCLAs metaloplásticos em Co-Cr e Ni-Cr, os quais foram fundidos ou sobrefundidos utilizando Co-Cr e Ni-Cr-Ti respectivamente (n=10). Com o auxílio da extensometria avaliou-se a tensão no momento da fixação da prótese sobre as replicas dos implantes. O teste estatístico empregado foi o ANOVA dois fatores, com o nível de significância de 5%. Os resultados obtidos apontam para um aumento na tensão gerada nos pilares calcináveis para ambas as ligas estudadas, sendo os pilares calcináveis em Co-Cr os que apresentaram os maiores valores de tensão. Nesse capítulo foi possível concluir que, os pilares sobrefundidos apresentaram menores valores de tensão. O segundo capítulo aborda diferentes metodologias usando strain gauges na avaliação da tensão. Foram confeccionados dois modelos para análise das tensões, um com gesso e duas réplicas de implantes, e outro em resina fotoelástica e dois implantes de conexão hexagonal externa. Foram utilizadas 40 infraestruturas metálicas utilizando pilares UCLAs calcináveis ou sobrefundidos em Co-Cr e Ni-Cr-Ti (n=10) totalizando oito grupos de estudo. A tensão foi avaliada em 3 momentos. Primeiramente no momento da fixação das peças sobre implantes ou réplicas, e posteriormente na aplicação de duas cargas com valores de 100 e 200N na região do pôntico (segundo pré-molar). O teste estatístico empregado foi o ANOVA de medidas repetidas com nível de significância de 5%. Os resultados mostraram que os pilares sobrefundidos em Co-Cr apresentaram os menores valores médios de tensão entre os grupos, e que existe diferença entre as técnicas empregadas para análise com strain gauges. Sendo assim, foi possível concluir que a liga de Co-Cr quando sobrefundida pode ser empregada na reabilitação com implantes e que a técnica que utiliza modelo com resina fotoelástica apresenta valores diferentes quando comparados aos modelo de gesso / Abstract: UCLA abutments are well accepted in dentistry because they allow reduced cost and individualization of prostheses according to each patient. However, when used for overcastting they har as prerogatives lower costs than the prefabricated abutments and better adaptation than the castables. Thus, the aim of this study was to evaluate the induction of stress to the implants by means of strain gages analysis, using prostheses made of UCLA overcast abutments in different alloys. This study presents two chapters, in which, the first is about the differences between the abutments calcinable and overcast and their respective alloys. For this, forty metal implant infrastructures were used simulating Fixed Partial Dentures of 3 elements, using conventional UCLAs abutments and overcast UCLAs in Co - Cr and Ni - Cr , which were cast or overcast using Co - Cr and Ni - Cr -Ti ( n = 10). With the aid of the strain gauge, the stress was evaluated at the time of fixation of the prosthesis on the replicas of the implants. The statistical test used was the two-factor ANOVA at a significance level of 5 %. The results indicate an increase in tension generated in the castable abutments for both alloys studied and also that, the abutments calcinable in Co - Cr present the highest levels of strain. So, in this chapter it was concluded that the lowest strain values are present in the overcast abutment . The second chapter discusses different methods using strain gauges and different values of tension. Two models were prepared for analysis of strain: one with plaster and two replicas of implants, and in other with photoelastic resin and two implants with hexagonal external connection. So, the forty infrastructures of calcinable or overcast UCLAs abutments in Co - Cr and Ni - Cr -Ti ( n = 10 ) were used, totaling eight study groups . The strain was assessed three times. First, at the time of fixation of implant parts or replicas, and after, at the application time of two loads with values of 100 and 200N on the pontic (second premolar). The statistical test used was ANOVA at the significance level of 5 %. The results showed that overcast UCLA abutment in Co - Cr present the lowest values of tension among the groups, and also that there is not difference between the techniques for analysis with strain gauges. Thus, one was concluded that the Co - Cr alloy, when with overcast abutments in Co-Cr, more suitable rehabilitation with implants. Furthermore, the technique with photoelastic resin model showed diference of tension when compared to the plaster model / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289173
Date02 June 2014
CreatorsLuthi, Leonardo Flores, 1984-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Henriques, Guilherme Elias Pessanha, 1968-, Rebelato, Cassius, Spazzin, Aloísio Oro, Mesquita, Marcelo Ferraz, Nóbilo, Mauro Antonio de Arruda
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguageInglês
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format42 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds