Return to search

Avaliação da eficiência energética em sistemasde iluminação predial = estudo de casos em dois hipermercados na cidade de Campo Grande - MS / Evaluation of the energy efficiency of lighting systems in comercial buildings : a case study in two hipermarkets in the city of Campo Grande-MS, Brazil

Orientador: Alberto Luiz Francato / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo. / Made available in DSpace on 2018-08-20T02:27:34Z (GMT). No. of bitstreams: 1
Mangiapelo_LeonardoBrunoSantos_M.pdf: 36586082 bytes, checksum: 8113b13216e191e2b209d281e23af5bc (MD5)
Previous issue date: 2012 / Resumo: No Brasil, as edificações são responsáveis por 45% do consumo de toda energia elétrica produzida no país, sendo 14,6% representado pelo setor comercial. Neste setor, os sistemas de iluminação artificial representam em média 22% do consumo de energia, apresentando grandes possibilidades para ações de eficiência energética. Estudos mostram que é possível reduzir 61% do custo com energia elétrica com ações de eficiência energética em sistemas de iluminação. Levantamentos realizados pelo Procel indicam que nos hipermercados 66,7% possuem potência instalada em iluminação acima de 100 kW, oferecendo grandes oportunidades para ações de eficiência energética no setor de iluminação. A integração da iluminação artificial com a natural possibilita grandes reduções nos custos com energia elétrica, além de proporcionar ambientes mais agradáveis e saudáveis para seus usuários. Ainda, estudos ressaltam que nos projetos luminotécnicos em geral, a eficiência energética do conjunto de equipamentos luminária-lâmpada-reator não costuma ser considerada, sendo comum a adoção de lâmpadas eficientes com luminárias ou reatores pouco eficientes. Neste trabalho, foram analisados dois hipermercados localizados na cidade de Campo Grande - MS. O hipermercado B possui um sistema de aberturas zenitais que possibilita o aproveitamento da iluminação natural e um conjunto de luminárias com refletores brancos e lâmpadas fluorescentes tubulares T8, enquanto o hipermercado A possui um sistema de fechamento com forro e um conjunto de luminárias com refletores metálicos e lâmpadas fluorescentes tubulares T5. Para realizar uma avaliação visando à eficiência energética de ambos os sistemas de iluminação destes hipermercados foram realizados levantamentos em campo, medições do consumo de energia elétrica nos circuitos de iluminação e também medições da distribuição dos níveis internos de iluminâncias. O estudo conclui que o aproveitamento da iluminação natural, associada ao correto dimensionamento do conjunto lâmpada luminária- reator e uso de sistemas automatizados oferecem grandes potenciais para a eficiência energética / Abstract: Buildings in Brazil are responsible for 45% of the whole electrical energy consumption, where 14,6% are performed in commercial buildings. In this sector, artificial lighting represent about 22% share of their energy consumption. Studies show that it is possible to reduce over 50% of the energy cost by implementing energy efficiency actions in lighting systems. According to PROCEL, the installed power with lighting in hypermarkets is greater than 100 kW in over 60% of the cases, thus representing an important type of building in the commercial sector. Additionally, studies show that the group efficiency of the lamp-ballast-luminary if often forgotten, yielding in inefficient lighting projects. The use of natural lighting integrated to the artificial lighting can offer not only potential to reduce energy consumption but also a more pleasant and healthy environment. This work describes a field study that was conducted in two different hypermarkets in the city of Campo Grande - MS in Brazil, with different artificial and natural lighting systems. The lighting system in hypermarket A consists of fluorescent T5 lamps in luminaries with reflexive components and no natural lighting openings while in hypermarket B, it consists of fluorescent T8 lamps in luminaries with no reflexive components and 12 openings for natural lighting. To evaluate and compare the energy efficiency of both lighting systems field research, energy consumption and lighting distribution measurements were carried out. The authors concluded that the use of natural lighting, associated with an efficient combination of lamp-luminary-ballast and automation systems offer great potential for energy efficiency / Mestrado / Recursos Hidricos, Energeticos e Ambientais / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258777
Date20 August 2018
CreatorsMangiapelo, Leonardo Bruno Santos
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Francato, Alberto Luiz, 1969-, Labaki, Lucila Chebel, Jota, Fabio Gonçalves
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format201 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds