Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-05-14T19:03:21Z
No. of bitstreams: 1
ELIANA PEREIRA DE SOUSA - DISSERTAÇÃO PPGSA PROFISSIONAL 2015..pdf: 1692020 bytes, checksum: 07e521abb68031a2118412065788e72e (MD5) / Made available in DSpace on 2018-05-14T19:03:21Z (GMT). No. of bitstreams: 1
ELIANA PEREIRA DE SOUSA - DISSERTAÇÃO PPGSA PROFISSIONAL 2015..pdf: 1692020 bytes, checksum: 07e521abb68031a2118412065788e72e (MD5)
Previous issue date: 2015 / A presente pesquisa investigou o desempenho do pós-tratamento de efluente de tanque séptico em filtros de areia de fluxos intermitentes, visando obter um esgoto tratado com qualidade adequada para reuso na irrigação. O esgoto doméstico foi proveniente do bloco de aulas II do Centro de Ciências e Tecnologia Agroalimentar (CCTA), da Universidade Federal de Campina Grande (UFCG). O controle de entrada do fluxo no sistema também foi quantificado. O sistema experimental foi constituído de um tanque séptico, três filtros de areia com fluxo intermitente e uma caixa de armazenamento. Os três filtros aeróbios de areia foram preenchidos com brita e areia na seguinte proporção: 10 cm de brita nº 1 na base, 50 cm de areia na porção mediana e 5 cm de brita nº 0 na porção superior. A areia utilizada nos três filtros foi a mesma, sendo peneirada numa peneira com diâmetro de 0,50 mm. O primeiro filtro recebeu 200 L/dia (50 L a cada 6hs) de efluente do tanque séptico, o segundo filtro recebeu 150 L/dia (50 L a cada 8hs) e o terceiro filtro recebeu 100 L/dia (50 L a cada 12hs). Realizaram-se campanhas de medição, no período de Novembro/2014 a Fevereiro/2015 para caracterizar os efluentes nos aspectos físico-químicos e microbiológicos como indicadores de transformação da qualidade
da água. Os parâmetros analisados foram: OD, temperatura, turbidez, pH, CE, cor, dureza
total, Ca, Mg, cloretos, N, Na, K, P, DQO, DBO5, CT, CTT e E.coli. A análise de variância
(ANOVA) foi realizada para comparar as concentrações de todos os parâmetros entre os efluentes, com nível de significância de 5%. Temperatura, turbidez, CE, cor, dureza total, Ca, Mg, cloretos, Na, K, P, DQO, DBO5, CT, CTT e E.coli não apresentaram diferenças estatísticas significantes. O OD apresentou significância. O N, muita significância e o pH, extrema significância estatística. Os filtros reduziram as concentrações de nutrientes, matéria orgânica e microorganismos patógenos, porém, com os reduzidos tempos de intermitências adotados não foi possível encontrar diferenças estatísticas entre os tratamentos. Os valores encontrados não foram compatíveis com os recomendados para uso na agricultura, segundo a Resolução do CONAMA. / This research investigated the performance of the post-treatment of septic tank effluent sand
filters intermittent flows, to obtain a treaty with sewage quality suitable for reuse in irrigation.
The sewage was coming from the classes of block II of the Center for Science and Technology
Agrifood (CCTA), the Federal University of Campina Grande (UFCG). The input flow
control in the system was also quantified. The experimental system was composed of a septic
tank of three sand filters with intermittent flow and a storage box. The three aerobic sand filters
were filled with gravel and sand at the following ratio: 10 cm crushed base # 1, 50 cm in
the middle portion sand and crushed stone No. 5 0 cm in the upper portion. The sand used in
the three filters was the same, being sieved through a sieve with a diameter of 0.50 mm. The
first filter received 200 L / day (50 L each 6am) of effluent from septic tank, the second filter
received 150 L / day (50 L every 8h) filter and the third received 100 L / day (50 L each
12pm). There were measurement campaigns, from November / 2014 to February / 2015 to
characterize the effluents in the physical, chemical and microbiological aspects as processing
indicators of water quality. The parameters analyzed were: OD, temperature, turbidity, pH,
EC, color, total hardness, Ca, Mg, chlorides, N, Na, K, P, COD, BOD 5, CT, CTT and E. coli.
The analysis of variance (ANOVA) was performed to compare the concentrations of all the
parameters in the effluent, at 5% significance level. Temperature, turbidity, EC, color, total
hardness, Ca, Mg, chlorides, Na, K, P, COD, BOD 5, CT, CTT and E. coli showed no statistically
significant differences. The OD showed significant. The N, much significance and the
pH, extreme statistical significance. The filters reduced the concentrations of nutrients, organic
matter and pathogenic microorganisms, but with reduced flickers adopted times could not
find statistical differences between treatments. These values were not compatible with those recommended for agricultural use, according to CONAMA resolution.
Identifer | oai:union.ndltd.org:IBICT/oai:localhost:riufcg/667 |
Date | 14 May 2018 |
Creators | SOUSA, Eliana Pereira de. |
Contributors | QUEIROZ, Manoel Moisés Ferreira de., ARAÚJO, Alfredina dos Santos., MARACAJÁ, Patrício Borges., PEREIRA JUNIOR, Ednaldo Barbosa. |
Publisher | Universidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM SISTEMAS AGROINDUSTRIAIS, UFCG, Brasil, Centro de Ciências e Tecnologia Agroalimentar - CCTA |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds