Return to search

Medida da captação de iodo pela tireóide: análise comparativa entre sistema gama-câmara com colimador "Pinhole" e sistema 13S002

Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-09-11T17:15:57Z
No. of bitstreams: 1
CARLOS BORGES DA SILVA M.pdf: 7893155 bytes, checksum: 84e1a26e71c1b5d623dacd41d743b105 (MD5) / Made available in DSpace on 2017-09-11T17:15:57Z (GMT). No. of bitstreams: 1
CARLOS BORGES DA SILVA M.pdf: 7893155 bytes, checksum: 84e1a26e71c1b5d623dacd41d743b105 (MD5)
Previous issue date: 2001-01 / A medida da captação do radio iodo absorvido na glândula tireoide é geralmente considerada direta e precisa, porém, têm-se observado certas discrepâncias nos resultados obtidos quando são realizadas comparações entre medidas, utilizando-se equipamentos diferentes. Este estudo tenta encontrar a causa destas diferenças nos ensaios realizados com sonda de captação convencional e uma gama-câmara. Estas discrepâncias podem ser atribuídas a diferenças entre populações de pacientes, problemas nos próprios equipamentos ou erros associados aos procedimentos experimentais. Neste trabalho são apresentados os resultados das medidas comparativas de captação "in-vitro" utilizando simulador de pescoço e de captação "in-vivo" em 40 pacientes 4 horas após a administração de 123 I, efetuadas com um Sistema Gama-Câmara Ohio Nuclear modelo Sigma 410 com colimador tipo "pinhole" e com o Sistema de Contagem para Medicina Nuclear modelo 13S002, também conhecido como Sonda de Captação para Tireoide, desenvolvido no Instituto de Engenharia Nuclear. O conjunto de dados demonstra que, embora a literatura referente ao assunto relate alguns resultados não satisfatórios, tanto o Sistema 13S002 quanto o Sistema Gama-Câmara Ohio podem ser utilizados indistintamente para aplicações de diagnóstico de tireoide com nível de confiança de 99 %, desde que sejam seguidos todos os parâmetros de geometria descritos neste trabalho. / The thyroid uptake measurements are common in medical uses and are considered a direct and precise form of diagnostic, however, different results have been observed as measurements thyroid. uptake are taken using distinct equipment. This study attempts to find the cause of the differences between a thyroid uptake probe and a gamma camera. These discrepancies can be associated to the different patients samples, equipment's problems or operator procedures errors. This work presents the results of comparative uptake measurements performed in a neck phantom and a 4-hour thyroid uptake study in 40 patients, using a Gamma Camera Ohio Nuclear model Sigma 410 with a pinhole collimator and Nuclear Medicine System model 13S002, developed by Instituto de Engenharia Nuclear. The results observed show that in spite of non satisfactory results commented in literature, both the System 13S002 and System Gamma Camera Ohio can be used in uptake thyroid diagnostic with statistical confidence degree of 99 %, since be followed all the procedures of geometry herein described.

Identiferoai:union.ndltd.org:IBICT/oai:carpedien.ien.gov.br:ien/1904
Date01 1900
CreatorsSilva, Carlos Borges da, Instituto de Engenharia Nuclear
ContributorsMorales, Rudnei Karam, Mello, Rossana Corbo R., Tauhata, Luiz, Cardoso, Domingos D'Oliveira, Rebelo, Ana Maria de O., Morales, Rudnei Karam, Mello, Rossana Corbo R. de
PublisherInstituto de Engenharia Nuclear, Programa de Pós-Graduação em Engenharia Nuclear, IEN, Brasil, Instituto Militar de Engenharia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional do IEN, instname:Instituto de Engenharia Nuclear, instacron:IEN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.002 seconds