Return to search

Corte de bolsa de sangue e medição de elasticidade de hemácias com laser infravermelho

Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-09-12T14:28:27Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Tese _Diógenes Soares Moura_final.pdf: 4560976 bytes, checksum: efbc9854c7666e2a40de8b98b027e62d (MD5) / Made available in DSpace on 2016-09-12T14:28:27Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Tese _Diógenes Soares Moura_final.pdf: 4560976 bytes, checksum: efbc9854c7666e2a40de8b98b027e62d (MD5)
Previous issue date: 2016-02-25 / CAPEs / O presente trabalho explora a utilização de lasers na região do infravermelho do espectro eletromagnético em aplicações biomédicas. O uso dos lasers na indústria, para processamento de materiais e em aplicações médicas, como a realização de cirurgias, têm atraído grande interesse nas últimas décadas. Neste trabalho, laser infravermelho foi explorado no corte de bolsas de sangue e no desenvolvimento de sistema de avaliação de elasticidade de hemácias baseado em técnica de aprisionamento óptico. No corte de bolsas de sangue foram determinados os parâmetros da ablação como tempo de perfuração, taxa de ablação e diâmetro dos furos para diferentes fluências e taxas de repetição do laser. Neste trabalho foram utilizados laser pulsados no regime de femtossegundos, com comprimento de onda de 800 nm, com taxa de repetição de 10 Hz e 1 KHz. Os resultados mostraram uma dependência do processo de ablação com o aumento da fluência e da taxa de repetição do laser. Além disso, foram avaliados os resíduos gasosos emitidos durante o processo de ablação das bolsas. A avaliação dos parâmetros de ablação à laser de bolsas de sangue consiste em um estudo pioneiro e introduz um novo direcionamento no processo de corte das mesmas. No desenvolvimento de um sistema para avaliação automática de elasticidade de hemácias aprisionadas opticamente foram utilizados lasers contínuos nos comprimentos de onda de 785 nm e 1064 nm. O sistema permite obter o valor da elasticidade de uma célula em 20 segundos, o que imprime uma redução significativa do tempo do processo de avaliação (60 ×) comparada ao método convencional. O sistema automático pode ajudar a expandir as aplicações de pinças ópticas em Hematologia e Hemoterapia. Além disto, o sistema construído foi utilizado para avaliar danos em hemácias aprisionadas opticamente. Foi verificada uma dependência da elasticidade das células com o comprimento de onda, potência do laser incidente e com tempo de aprisionamento da hemácia. Observou-se que as hemácias, após 2 minutos de exposição ao laser de 785 nm tornaram-se até ~ 104% menos deformáveis que as hemácias controle. A exposição ao laser de 1064 nm de 2 minutos a 10 mW induziu um aumento de até ~ 20% na rigidez celular. Atribuiu-se a dependência do comprimento de onda dos danos ópticos à absorção do laser pela hemoglobina. As modificações observadas nas propriedades elásticas das células estudadas estabelecem novos limites para aplicações utilizando lasers em hemácias. / This work explores the use of lasers in the infrared region of the electromagnetic spectrum in biomedical applications. The use of lasers in industry for materials processing and in medical applications, such as in surgeries, have attracted great interest in recent decades. In this work, infrared lasers were explored in blood bags cutting and in the development of a red blood cells elasticity evaluation system based on optical trapping technique. For the blood bags cutting process, ablation parameters such as drilling time, ablation rate and ablation diameter for different laser fluence and repetition rates were determined. In this work we used pulsed laser in femtosecond regime, with a wavelength of 800 nm, with repetition rate of 10 Hz and 1 KHz. The results showed a dependence of the ablation process with laser fluence and repetition rate. In addition, the waste gases emitted during the blood bags ablation process were evaluated. The evaluation of the blood bag laser ablation parameters consists of a pioneering study and introduces a new direction in the blood bag cutting process. In the development of a system for automatic evaluation elasticity of optically trapped red blood cells (RBCs), continuous laser at a wavelength of 785 nm and 1064 nm were used. The system allows to obtain the value of cell elasticity in 20 seconds, establishing a significant reduction in the assessment process time (× 60) compared to the conventional method. The automated system can help expand the applications of optical tweezers in Hematology and Hemotherapy. In addition, the constructed system was used to evaluate damage to red blood cells optically trapped. A dependence of the cells elasticity with the wavelength and power laser and with cell time trapping was observed. The results shows that the red blood cells was up to ~104% less deformable after 2 minutes of 785 nm laser exposition. The 2 minutes exposure to 10 mW of 1064 nm laser induced an increase up to ~ 20% on cell rigidity. We ascribed the wavelength dependence of the optical damages to the laser absorption by the hemoglobin. Moreover, the increase of RBCs rigidity could be associated to initial changes optically caused in the hemoglobin after irradiation. The results establish new limits for laser applications in RBCs, by identifying considerable modifications on their elastic properties.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpe.br:123456789/17825
Date25 February 2016
CreatorsMOURA, Diógenes Soares
Contributorshttp://lattes.cnpq.br/6149477863429826, ARAÚJO, Renato Evangelista de
PublisherUniversidade Federal de Pernambuco, Programa de Pos Graduacao em Engenharia Eletrica, UFPE, Brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Repositório Institucional da UFPE, instname:Universidade Federal de Pernambuco, instacron:UFPE
RightsAttribution-NonCommercial-NoDerivs 3.0 Brazil, http://creativecommons.org/licenses/by-nc-nd/3.0/br/, info:eu-repo/semantics/openAccess

Page generated in 0.0019 seconds