Return to search

Desenvolvimento de um sistema de controle automático para condicionamento de ar de secagem / Development of an automatic control system to condition drying air

Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-31T16:52:06Z
No. of bitstreams: 1
texto completo.pdf: 2344376 bytes, checksum: e39397755e2d8ce9c0f57409e180b30b (MD5) / Made available in DSpace on 2017-05-31T16:52:06Z (GMT). No. of bitstreams: 1
texto completo.pdf: 2344376 bytes, checksum: e39397755e2d8ce9c0f57409e180b30b (MD5)
Previous issue date: 2010-07-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A secagem dos produtos agrícolas é o processo mais utilizado para assegurar sua qualidade e estabilidade. Neste trabalho foi desenvolvido um sistema automático para realizar o controle sobre o ciclo de funcionamento de uma bomba de calor de forma a permitir que a mesma seja usada tanto para secagem quanto para aeração de grãos. Quando utilizada no processo de secagem, o sistema de controle é capaz de manter o ar de secagem com temperatura constante e umidade relativa dentro dos parâmetros definidos pelo usuário. Quando utilizada no processo de aeração, o sistema de controle é capaz de manter o ar de saída com valores de temperatura e umidade relativa tais que mantenham a relação de umidade de equilíbrio constante, em resposta às variações ocorridas no ar ambiente. Para o desenvolvimento deste sistema de controle foi utilizado um microcontrolador PIC 18F4550 da microchip, sensores de temperatura LM35 da National Semicondutor e sensores de umidade relativa HIH 4000-004 da Honeywell. Para realizar a ação de controle foi implementado uma estratégia de controle PID em linguagem C para microcontroladores, que de posse dos valores de temperatura e umidade relativa do ar ambiente, do ar na saída da bomba de calor e do ar na saída do silo secador, calcula os erros entre os valores medidos e os desejados. De posse dos valores destes erros, a estratégia de controle PID tende a minimizá-los atuando nos inversores de frequência que controlam o funcionamento do compressor e do ventilador da bomba de calor. Para o caso em que a umidade relativa do ar ambiente estivesse abaixo do valor mínimo para manter a umidade de equilíbrio durante o processo de aeração, foi desenvolvido um sistema borrifador que quando acionado pelo sistema de controle libera água em forma de névoa na entrada da bomba de calor, elevando-se assim a umidade relativa do ar a ser processado. Em todos os testes realizados para a validação do sistema de controle o mesmo foi capaz de manter os valores de temperatura e umidade relativa de acordo com os valores escolhidos, dentro da faixa de operação da bomba de calor utilizada, respondendo de forma satisfatória às variações ocorridas no ar ambiente. / The drying of agricultural products is the most used process to make certain its quality and stability. In this work was developed an automatic system to control the operation cycle of a heat pump with the purpose of to be used both in drier and in aeration of grains. When the heat pump is used in drier process, the control system is able to maintain the dryer air with constant temperature and humidity according to the parameters defined by the user. When used in the aeration process, the control system is able to maintain the air with values of temperature and humidity in such a way which keep moisture content of the grains constant, irrespective of environment changes. In the development of the control system a microcontroller PIC 18F4550, temperature sensors LM35 by National Semiconductors and Humidity sensors HIH 4000-004 by Honeywell was used. To produce the control action a PID control strategy was implemented in language C for microcontrollers, where reading the temperature and humidity sensors disposed at the environment, at the air exit of the heat pump and at the air exit of the grain store, the errors between the desired and the reads values is calculated. With the values of these errors, the PID control strategy try to keep it at the minimum value acting in the frequency inverters which control the compressor and the fan speed of the heat pump. To the case which the environment air humidity is below of the minimum value to maintain moisture contents of the grains in the aeration process, a spray system was purpose- built to produce a mist, when the system is turned on, in the air at the heat pump entrance, adding humidity to the air. After several tests to validate the performance of the control system developed in this work, was possible verify that the system is able to keep temperature and humidity of the air according with the values of set-point defined by user, respecting the operation range of the heat pump, independent of the environment changes. / Não foi localizado o cpf do autor.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:123456789/10453
Date27 July 2010
CreatorsNicacio, José Vitor
ContributorsLacerda Filho, Adílio Flauzinio de, Pizziolo, Tarcísio de Assunção, Martins, José Helvécio, Melo, Evandro de Castro
PublisherUniversidade Federal de Viçosa
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFV, instname:Universidade Federal de Viçosa, instacron:UFV
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds