Return to search

Efeito da aplicação de carga em coroas de diferentes materiais, confeccionadas sobre implantes unitários curtos e com diferentes diâmetros nas deformações da crista óssea : análise in vitro e in silico /

Orientador: Lafayette Nogueira Junior / Banca: Guilherme de Siqueira Ferreira Anzaloni Saavedra / Banca: Dárcio Kitakawa / Resumo: O intuito deste estudo in vitro e in silico, foi analisar as microdeformações, geradas pela aplicação de carga vertical, sobre coroas de 3 tipos de materiais restauradores diferentes (Zircônia, Dissilicato de Lítio e Cromo Cobalto), que foram selecionadas, através da biblioteca do software SMART DENT/Exocad (Darmstadt - Germany) e confeccionadas, através da tecnologia cad/cam, suportadas por implantes curtos (8mm), conexão cone morse, com diversos diâmetros (3,5 mm; 4,0 mm e 5,0 mm). Os implantes foram instalados 2mm infraósseo para análise através de elementos finitos e da extensometria. Foram confeccionados 3 blocos de poliuretano: bloco 1 (grupo experimento) no qual foi colocado um implante Titamax CM Neodent 3,5 X 08 mm, bloco 2 (grupo controle) no qual foi colocado um implante titamax CM Neodent 4,0 X 08 mm e bloco 3 (grupo controle) no qual foi colocado um implante titamax CM Neodent 5,0 X 08 mm. Pilares protéticos retos (Base de Titânio 4,5 - Neodent) foram instalados sobre os respectivos implantes sendo instalados 4 extensômetros, na região superior dos blocos ao redor dos implantes. Foi aplicada uma carga vertical de 300N ao redor da abertura de acesso do parafuso protético das coroas. Para a análise por elementos finitos (FEA), o mesmo bloco foi modelado e analisado sob a mesma carga de 300N. Os valores de tensão e deformação foram analisados quanto à correlação com a extensometria. A estatística inferencial consistiu no teste de análise de variância de Friedmann, u... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this in vitro and in silico study was to analyze the microdeformations generated by the application of vertical load on crowns of 3 different types of restorative materials (Zirconia, Lithium Dissilicate and Cobalt Chromium) that were selected through the software library SMART DENT / Exocad (Darmstadt - Germany), and made using cad / cam technology, supported by short implants (8 mm), cone morse connection with various diameters (3.5 mm, 4.0 mm and 5.0 mm). These were installed 2 mm subcrestal for finite element analysis and extensometry. Three blocks of polyurethane were made; block 1 (experimental group) in which a Titamax CM Neodent 3.5 X 08 mm implant, block 2 (control group) was implanted in which a CM Neodent 4.0 X 08 mm titamax and block 3 (control group) were implanted in which an implant was placed titamax CM Neodent 5.0 X 08 mm. Straight prosthetic abutments (Titanium Base 4.5 - Neodent) were installed on the respective implants and 4 extensometers were installed, in the upper region of the blocks around the implants. A vertical load of 300N was applied around the access opening of the crown prosthetic screw. For the finite element analysis (FEA), the same block was modeled and analyzed under the same 300N load. The stress and strain values were analyzed for correlation with extensometry. The inferential statistics consisted of Friedmann's analysis of variance, a fixed effect factor. For the level of significance, the conventional value of 5% was chosen.... (Complete abstract click electronic access below) / Mestre

Identiferoai:union.ndltd.org:UNESP/oai:www.athena.biblioteca.unesp.br:UEP01-000906033
Date January 2018
CreatorsMonteiro, Fabricio Malheiros de Miranda.
ContributorsUniversidade Estadual Paulista "Julio de Mesquita Filho" Instituto de Ciência e Tecnologia (Campus de São José dos Campos).
PublisherSão José dos Campos,
Source SetsUniversidade Estadual Paulista
LanguagePortuguese, Portuguese, Texto em português; resumos em português e inglês
Detected LanguageEnglish
Typetext
Format88 f. :
RelationSistema requerido: Adobe Acrobat Reader

Page generated in 0.0019 seconds