Return to search

Determinação do perfil farmacocinético de fármacos com ação anti-hipertensiva aplicados à clínica / Determination of the pharmacokinetic profile of drugs with anti-hypertensive action applied to clinical

Orientador: Ney Carter do Carmo Borges / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-18T16:31:42Z (GMT). No. of bitstreams: 1
Moreira_RobertoFernandes_M.pdf: 9049271 bytes, checksum: da0d5e2ef677c3ea82ea931de845e3f8 (MD5)
Previous issue date: 2011 / Resumo: O presente trabalho avaliou o perfil farmacocinético de dois medicamentos anti-hipertensivos, contendo associação de losartana 100 mg + hidroclorotiazida 25 mg na forma farmacêutica de comprimidos revestidos. Foi utilizado um método bioanalítico, apropriado e validado, de determinação simultânea de ambos fármacos para avaliação da biodisponibilidade relativa, de acordo com os critérios de bioequivalência. O estudo foi aberto, randomizado, cruzado, com dois tratamentos, duas seqüências e dois períodos. Os voluntários receberam, em cada período, a formulação teste ou a formulação referência. Vinte e oito voluntários adultos, sadios, de ambos os sexos foram incluídos. Amostras de sangue venoso foram coletadas em tempos pré-determinados. O plasma foi obtido por centrifugação a 3000 rpm por 10 min, e armazenado a -20 °C até a determinação das concentrações de losartana e hidroclorotiazida. O método bioanalítico utilizou a extração líquido-líquido, seguido pela Cromatografia Líquida de Alta Eficiência acoplada a Espectrometria de Massa (HPLC-MS-MS). Com base no intervalo de confiança de 90% dos índices individuais para Cmax e ASC0-t, estabelecidos pela ANVISA e FDA, concluiu-se que a formulação teste é bioequivalente a formulação referência Hyzaar® para extensão e taxa de absorção de losartana e hidroclorotiazida / Abstract: This study evaluated the pharmacokinetic profile of two antihypertensive drugs containing a combination of 100mg losartan plus 25mg hydrochlorothiazide formulated in coated tablets. Appropriate and validated bioanalytical methods for simultaneous determination of both drugs were used to evaluate the relative bioavailability, based on the bioequivalence criteria. This was an open-label, randomized, crossover, two treatments, two sequences, two periods trial. The volunteers received in each period, either the test or the reference formulation. Twenty-eight healthy adults volunteers, of both sexes were enrolled. Venous blood samples were collected at predeterminated times. The plasma was obtained by centrifugation at 3000 rpm for 10 min and stored at -20° C until the determination of concentrations of losartan and hydrochlorothiazide. The bioanalytical method used the liquid-liquid extraction, followed by High Performance Liquid Chromatography with tandem mass spectrometry (HPLC-MS-MS). Based on the confidence interval of 90% of the individual indexes for Cmax and AUC0-t, established by ANVISA and FDA, it was concluded that the test formulation is bioequivalent to the reference formulation Hyzaar® for the extent and rate of absorption of losartan and hydrochlorothiazide / Mestrado / Ciencias Basicas / Mestre em Clinica Medica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/311496
Date08 December 2011
CreatorsMoreira, Roberto Fernandes, 1979-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Borges, Ney Carter do Carmo, Barros, Fabio Alessandro Proença, Nogueira, Eduardo Arantes
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Clínica Médica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format249 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds