Return to search

Avaliação in vitro da precisão de técnicas de moldagens para implantes osseointegrados / In vitro evaluation of the accuracy of techniques of moldings for osseointegrated dental implants

Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T00:42:59Z (GMT). No. of bitstreams: 1
Braga_FranciscoPantoja_M.pdf: 1746788 bytes, checksum: 2e92ba56c05af0022643d89add3ac42c (MD5)
Previous issue date: 2010 / Resumo: Este estudo In vitro teve como objetivo avaliar a precisão de quatro técnicas de moldagens para implantes ósseo integrados. A partir de uma matriz metálica contendo três implantes foi construída uma supraestrutura simulando uma prótese. As quatro técnicas estudadas foram assim separadas: Grupo A - 10 moldagens com transferentes cônicos (sem união) em moldeiras individuais fechadas; Grupo B - 10 moldagens com transferentes quadrados isolados em moldeiras abertas; Grupo C - 10 moldagens com transferentes quadrados unidos com resina autopolimerizável em moldeiras individuais abertas; Grupo D - 10 moldagens com transferentes quadrados unidos com resina composta Bis-acrílica autopolimerizável em moldeiras individuais abertas. O material de moldagem para todos os grupos foi o silicone de adição Honigum Mono (DMG) e o gesso utilizado para a fabricação dos modelos foi Resin Rock (Whip Mix-USA). Desajustes marginais foram avaliados entre a supra estrutura metálica parafusada aos modelos de trabalho obtidos a partir das moldagens utilizando-se microscópio óptico (aumento de 120X), assim como as tensões induzidas à supraestrutura, avaliadas por extensometria. Para a comparação dos grupos foi utilizado o teste não-paramétrico de Kruskal-Wallis com nível de significância de 5%, para a verificação de existência de diferença significativa entre os grupos com respeito às duas variáveis estudadas. Utilizou-se comparações múltiplas não-paramétricas, para indicar qual ou quais os grupos que levaram à significância estatística. O teste de Kruskal-Wallis para a variável tensão apresentou valor de p= 0,0043 e para a variável desajuste o p encontrado foi igual a 0,6073. Sendo 5% o nível fixado, foi possível observar que apenas para a variável tensão os grupos apresentaram diferença significativa entre si. Foi calculado o coeficiente de correlação de Pearson para as variáveis tensão e desajuste, indicando correlação positiva entre as variáveis. Esta correlação foi altamente significativa (p=0,0074). Os demais valores encontrados não apresentaram significância
estatística. Concluiu-se que a mais precisa dentre as quatro técnicas estudadas foi a que usou transferentes quadrados esplintados com bastões de resina pré- fabricados e que houve correlação direta entre desajuste marginal e tensões geradas à supraestrutura / Abstract: The main objective of this study in vitro is to evaluate the accuracy of four techniques of moldings implants osseointegrated. Starting from a metallic matrix with three implants, simulating a clinical situation, was constructed one super structure simulating one prosthesis. The four studied techniques were separated like this: Group A - 10 impressions with conic transfer in closed custom tray; Group B- 10 impressions with square transfer isolated in open custom tray; Group C- 10 impressions with square transfer splinted with autopolymerizing acrylic resin; Group D- 10 impressions taken with square transfer splinted with composite resin Bis-acrilic autopolymerizing in open custom tray. The impression taken material for all groups was vinyl polysiloxane Honigum (DMG), and the gypsum used was Resin Rock (Whip Mix-USA). Strains were analyzed by the use of strain gauges and misfit was analyzed by an optical microscope. The non-parametric test of Kruskal-Wallis was used to compare the 4 groups with a 5% level of significance to verify the significant difference among the groups with respect of the two studied variables. Multiple comparisons were used and they were non-parametric to indicate which group or groups will carry significance to statistics. The Kruskal-Wallis test as far as tension is concerned presented the value of p= 0.0043 and as far as misfit is concerned the p found was 0.6073. Being 5% the level established it is possible to observe that only the variable of tension in the groups show a significant difference among themselves. The correlated coefficient of Pearson was calculated between tension and misfit to each set of data in all the groups evaluated in the research, indicating positive correlation between tension and misfit. This correlation is highly significant (p-value 0.0074). The other values were not statistically significant. Conclusion: The most precise technique of the four was the one that used squared splinted transfers with prefabricated stick autopolymerizing acrylic resin and it had direct correlation between among misfit and tensions generated in the super structure / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289178
Date16 August 2018
CreatorsBraga, Francisco Pantoja
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Henriques, Guilherme Elias Pessanha, 1968-, Junior, Francisco de Assis Mollo, Nóbilo, Mauro Antonio de Arruda
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format114 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0016 seconds