1 |
Confiabilidade de diferentes métodos de aquisição de modelos dentários digitais / Confiabilidade de diferentes métodos de aquisição de modelos dentários digitais / Reliability of different methods of acquiring digital dental casts / Reliability of different methods of acquiring digital dental castsGeorge Nunes Bueno 29 January 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O uso de modelos de estudo dentários faz parte tanto da prática quanto da pesquisa odontológica e ortodôntica. Com a introdução dos scanners 3D e dos tomógrafos CBCT (cone beam computer tomography) tornou-se possível a obtenção de modelos dentários tridimensionais virtuais das arcadas dentárias. Foram selecionados 56 modelos dentários superiores e escaneados em três tipos diferentes de scanners: Maestro 3D Dental Scanner (AGE Solutions, Potedera, Italia), 3Shape R700 3D Scanner (3Shape, Copenhagen, Dinamarca) e o scanner 3Shape TRIOS (3Shape, Copenhagen, Dinamarca). Doze medidas foram realizadas nos modelos dentários de gesso e comparadas com as mesmas medidas realizadas nos modelos dentários digitais por meio do teste de Análise de Variância (ANOVA). Estatisticamente não foram encontradas diferenças significativas entre as medições tradicionais nos modelos dentários de gesso e as medidas realizadas nos modelos dentários digitais. Os três tipos de métodos de aquisição de modelos dentários digitais foram considerados confiáveis para as medições horizontais, transversais e verticais. Os modelos dentários virtuais podem ser indicados como substitutos dos modelos dentários de gesso. / The use of dental study casts is part of the practice and research in dentistry and orthodontics. With the advent of 3D scanners and CBCT (cone beam computer tomography) scanners, it became possible to obtain three-dimensional virtual dental casts of the dental arches. 56 upper dental casts were selected and scanned in three different types of scanners: Maestro 3D Dental Scanner (AGE Solutions, Potedera, Italy), 3Shape R700 3D Scanner (3Shape, Copenhagen, Denmark) and 3Shape TRIOS scanner (3Shape, Copenhagen, Denmark). 12 Measurements were performed on dental plaster models and compared with the same measurements in digital dental models through test Analysis of Variance (ANOVA). No statistically significant differences were found between the traditional measurements in dental plaster models and measurements taken in the digital dental models. The three kinds of methods to acquire digital dental models were considered reliable for horizontal, vertical and cross measurements. The virtual dental models can be indicated as substitutes for dental plaster models.
|
2 |
Confiabilidade de diferentes métodos de aquisição de modelos dentários digitais / Confiabilidade de diferentes métodos de aquisição de modelos dentários digitais / Reliability of different methods of acquiring digital dental casts / Reliability of different methods of acquiring digital dental castsGeorge Nunes Bueno 29 January 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O uso de modelos de estudo dentários faz parte tanto da prática quanto da pesquisa odontológica e ortodôntica. Com a introdução dos scanners 3D e dos tomógrafos CBCT (cone beam computer tomography) tornou-se possível a obtenção de modelos dentários tridimensionais virtuais das arcadas dentárias. Foram selecionados 56 modelos dentários superiores e escaneados em três tipos diferentes de scanners: Maestro 3D Dental Scanner (AGE Solutions, Potedera, Italia), 3Shape R700 3D Scanner (3Shape, Copenhagen, Dinamarca) e o scanner 3Shape TRIOS (3Shape, Copenhagen, Dinamarca). Doze medidas foram realizadas nos modelos dentários de gesso e comparadas com as mesmas medidas realizadas nos modelos dentários digitais por meio do teste de Análise de Variância (ANOVA). Estatisticamente não foram encontradas diferenças significativas entre as medições tradicionais nos modelos dentários de gesso e as medidas realizadas nos modelos dentários digitais. Os três tipos de métodos de aquisição de modelos dentários digitais foram considerados confiáveis para as medições horizontais, transversais e verticais. Os modelos dentários virtuais podem ser indicados como substitutos dos modelos dentários de gesso. / The use of dental study casts is part of the practice and research in dentistry and orthodontics. With the advent of 3D scanners and CBCT (cone beam computer tomography) scanners, it became possible to obtain three-dimensional virtual dental casts of the dental arches. 56 upper dental casts were selected and scanned in three different types of scanners: Maestro 3D Dental Scanner (AGE Solutions, Potedera, Italy), 3Shape R700 3D Scanner (3Shape, Copenhagen, Denmark) and 3Shape TRIOS scanner (3Shape, Copenhagen, Denmark). 12 Measurements were performed on dental plaster models and compared with the same measurements in digital dental models through test Analysis of Variance (ANOVA). No statistically significant differences were found between the traditional measurements in dental plaster models and measurements taken in the digital dental models. The three kinds of methods to acquire digital dental models were considered reliable for horizontal, vertical and cross measurements. The virtual dental models can be indicated as substitutes for dental plaster models.
|
3 |
Comparação da distribuição de tensões em dois tipos de conexão protética de implantes com parafusos diferentes utilizando o método de análise por elementos finitos com modelo tridimensionalHerbstrith Segundo, Regênio Mahfuz January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2
000388162-0.pdf: 14806898 bytes, checksum: 307d9a5db880718206e03f9e7a7c7223 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to compare and evaluate, through 3D finite element analysis, strain distribution generate by simulated loads over implants, abutments and metal ceramic crowns models in first molars region. The analysis were executed in four 3D models: model 1 and 2 with external butt joint, with gold and titanium abutment screw, respectively, model 2 and 3 with internal butt joint, with gold and titanium abutment screw, respectively, the standard load was 382N with two different angulations, 90º to occlusal surface and 15º to implant axis, and in two distinct points 4 and 6mm of the implant center, in ten different observation points on the implantabutment- screw set. The results suggested that in a general way, the internal butt joint models (3 and 4) showed a better mechanic behavior related to strain distribution along the implant-abutment-screw set. On the models 1 and 2, the abutment screw material had a great influence on the strain distribution. On the other hand, models 3 and 4 have no such behavior. / O objetivo deste estudo foi avaliar e comparar qualitativamente, através de análise por elementos finitos com modelo 3D, a distribuição das tensões geradas por cargas simuladas sob modelos de implantes, pilares, coroas protéticas metalocerâmicas na região de primeiros molares. As análises foram executadas em 4 modelos tridimensionais: modelo 1 e modelo 2 com encaixe protético tipo hexágono externo e parafuso de pilar de ouro e titânio respectivamente, modelo 3 e modelo 4 com encaixe tipo hexágono interno e parafuso de pilar de ouro e titânio respectivamente, a carga aplicada foi padronizada em 382N com duas angulações diferentes, inclinações de 90º com a superfície oclusal e de 15º em relação ao longo eixo dos implantes, em dois pontos distintos, 4 e 6 mm do centro do implante, em 10 pontos diferentes de observação no conjunto implante-pilar-parafuso. Os resultados obtidos sugeriram que de uma maneira geral, os modelos com encaixe interno (3 e 4) possuem um melhor comportamento mecânico em relação a distribuição de tensões ao longo do complexo implante-pilar-parafuso. Nos modelos 1 e 2 o tipo de material que o parafuso de pilar é feito influencia na distribuição de tensões, por outro lado, nos modelos 3 e 4 isto não foi observado.
|
4 |
Avaliação in vitro da precisão de técnicas de moldagens para implantes osseointegrados / In vitro evaluation of the accuracy of techniques of moldings for osseointegrated dental implantsBraga, Francisco Pantoja 16 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T00:42:59Z (GMT). No. of bitstreams: 1
Braga_FranciscoPantoja_M.pdf: 1746788 bytes, checksum: 2e92ba56c05af0022643d89add3ac42c (MD5)
Previous issue date: 2010 / Resumo: Este estudo In vitro teve como objetivo avaliar a precisão de quatro técnicas de moldagens para implantes ósseo integrados. A partir de uma matriz metálica contendo três implantes foi construída uma supraestrutura simulando uma prótese. As quatro técnicas estudadas foram assim separadas: Grupo A - 10 moldagens com transferentes cônicos (sem união) em moldeiras individuais fechadas; Grupo B - 10 moldagens com transferentes quadrados isolados em moldeiras abertas; Grupo C - 10 moldagens com transferentes quadrados unidos com resina autopolimerizável em moldeiras individuais abertas; Grupo D - 10 moldagens com transferentes quadrados unidos com resina composta Bis-acrílica autopolimerizável em moldeiras individuais abertas. O material de moldagem para todos os grupos foi o silicone de adição Honigum Mono (DMG) e o gesso utilizado para a fabricação dos modelos foi Resin Rock (Whip Mix-USA). Desajustes marginais foram avaliados entre a supra estrutura metálica parafusada aos modelos de trabalho obtidos a partir das moldagens utilizando-se microscópio óptico (aumento de 120X), assim como as tensões induzidas à supraestrutura, avaliadas por extensometria. Para a comparação dos grupos foi utilizado o teste não-paramétrico de Kruskal-Wallis com nível de significância de 5%, para a verificação de existência de diferença significativa entre os grupos com respeito às duas variáveis estudadas. Utilizou-se comparações múltiplas não-paramétricas, para indicar qual ou quais os grupos que levaram à significância estatística. O teste de Kruskal-Wallis para a variável tensão apresentou valor de p= 0,0043 e para a variável desajuste o p encontrado foi igual a 0,6073. Sendo 5% o nível fixado, foi possível observar que apenas para a variável tensão os grupos apresentaram diferença significativa entre si. Foi calculado o coeficiente de correlação de Pearson para as variáveis tensão e desajuste, indicando correlação positiva entre as variáveis. Esta correlação foi altamente significativa (p=0,0074). Os demais valores encontrados não apresentaram significância
estatística. Concluiu-se que a mais precisa dentre as quatro técnicas estudadas foi a que usou transferentes quadrados esplintados com bastões de resina pré- fabricados e que houve correlação direta entre desajuste marginal e tensões geradas à supraestrutura / Abstract: The main objective of this study in vitro is to evaluate the accuracy of four techniques of moldings implants osseointegrated. Starting from a metallic matrix with three implants, simulating a clinical situation, was constructed one super structure simulating one prosthesis. The four studied techniques were separated like this: Group A - 10 impressions with conic transfer in closed custom tray; Group B- 10 impressions with square transfer isolated in open custom tray; Group C- 10 impressions with square transfer splinted with autopolymerizing acrylic resin; Group D- 10 impressions taken with square transfer splinted with composite resin Bis-acrilic autopolymerizing in open custom tray. The impression taken material for all groups was vinyl polysiloxane Honigum (DMG), and the gypsum used was Resin Rock (Whip Mix-USA). Strains were analyzed by the use of strain gauges and misfit was analyzed by an optical microscope. The non-parametric test of Kruskal-Wallis was used to compare the 4 groups with a 5% level of significance to verify the significant difference among the groups with respect of the two studied variables. Multiple comparisons were used and they were non-parametric to indicate which group or groups will carry significance to statistics. The Kruskal-Wallis test as far as tension is concerned presented the value of p= 0.0043 and as far as misfit is concerned the p found was 0.6073. Being 5% the level established it is possible to observe that only the variable of tension in the groups show a significant difference among themselves. The correlated coefficient of Pearson was calculated between tension and misfit to each set of data in all the groups evaluated in the research, indicating positive correlation between tension and misfit. This correlation is highly significant (p-value 0.0074). The other values were not statistically significant. Conclusion: The most precise technique of the four was the one that used squared splinted transfers with prefabricated stick autopolymerizing acrylic resin and it had direct correlation between among misfit and tensions generated in the super structure / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
5 |
Confiabilidade de medidas realizadas em modelos virtuais obtidos a partir do escaneamento de moldagens e de modelos de gesso convencionais / Reliability of measurements performed on virtual models obtained from scanning of impressions and conventional plaster modelsMoreira, Debora Duarte, 1986- 22 August 2018 (has links)
Orientador: Gláucia Maria Bovi Ambrosano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T09:24:55Z (GMT). No. of bitstreams: 1
Moreira_DeboraDuarte_M.pdf: 1498990 bytes, checksum: c7b7801745e1bf94bcf13b498805567b (MD5)
Previous issue date: 2013 / Resumo: O objetivo deste estudo foi comparar as medidas obtidas em modelos virtuais das moldagens e em modelos virtuais dos modelos de gesso com as obtidas em modelos de gesso. Os modelos virtuais foram obtidos pelo escaneamento da moldagem e do modelo de gesso em um scanner de superfície a laser (R700; 3Shape, Copenhage, Dinamarca) e as medidas foram realizadas com o software OrthoAnalyser (3Shape, Copenhage, Dinamarca). Os modelos de gesso convencionais foram mensurados com a utilização de um paquímetro digital. A amostra foi constituída de 26 pacientes selecionados aleatoriamente que foram submetidos a uma moldagem das arcadas superior e inferior com alginato e um registro de mordida com cera utilidade. As mensurações nos modelos de gesso, virtual da moldagem e virtual do modelo foram realizadas por três avaliadores devidamente treinados. Os dados foram tabulados e submetidos à análise estatística de correlação intraclasse para verificar a concordância das medidas intraavaliador e interavaliador e ao teste ANOVA para analisar diferenças nas medidas obtidas dos modelos virtuais da moldagem e do modelo. Os resultados mostraram existir diferença estatística significante (p?0,05) de 0,09 mm a 0,43 mm para dentes da região posterior e da região anterior e de 0,51 mm a 1,13 mm para perímetro do arco superior e distância intercaninos inferior, se comparados os modelos virtuais com os modelos de gesso; porém essas diferenças foram consideradas clinicamente aceitáveis. Foi possível concluir que os modelos digitais são uma alternativa confiável aos modelos de gesso / Abstract: The aim of this study was to compare measurements of digital models obtained from plaster models scans, alginate impression scans to those obtained from conventional plaster models. The plaster models and alginate impressions were scanned using a optical surface scanner (R700; 3Shape, Copenhage, Dinamarca) and the measurements were performed using proprietary software OrthoAnalyser (3Shape, Copenhagen, Denmark). The plaster models ware measured by using a caliper. The sample was comprised of 26 pacients randomly selected to have impressions of their upper and lower jaws taken using alginate and their bite registration using a wax bite. The measurements on the plaster model, digital impression and digital model were performed by three observers calibrated. The data was analyzed statistically by the intraclass correlation to assess the agreement of the measurements for the intra and inter-observers. ANOVA test was used to analyze the differences between the three different objects (plaster model, digital model from plaster and digital model from impression). The results showed there is a statistically significant difference (p?0,05) 0,09 mm to 0,43 mm to the posterior teeth and the anterior region, and 0,51 mm to 1,13 mm to upper arch length and lower inter-canine distance if compared digital models with plaster models, but these differences were found to be clinically acceptable. We concluded that the measurements taken from digital models can be a reliable alternative to conventional plaster models for orthodontic diagnosis purposes / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
|
6 |
Morfoanálise tridimensional dos arcos dentários de crianças com fissura completa de lábio e palato unilateral / 3D morphology of dental arches in children with complete cleft lip and unilateral palateBerbert, Christiane Camargo Villela 03 December 2018 (has links)
O objetivo deste trabalho foi realizar uma avaliação das áreas e das medidas lineares dos arcos dentários de crianças com fissura de lábio e palato unilateral (FLPU), aos cinco anos de idade. A amostra foi composta de 60 modelos digitais de maxila e de mandíbula de crianças com FLPU (p=30) (Grupo 1) e pacientes sem fissura (p=30) (Grupo 2). Os modelos de gesso foram digitalizados, por meio do Scanner 3 Shapes R700TM. Foram avaliadas as medidas lineares transversais (C-C) e ( M-M), lineares longitudinais (I-2MD), (I-2ME) e perpendicular (I-CC) e (I-MM) pelo Software Appliance Designer. As aferições das áreas total e parciais dos arcos dentários nos grupos de estudo foram pontuados e avaliados pelo Software do Sistema Estereofotogrametria. Para as análises dos resultados foi aplicado o Teste t , para verificar as alterações ocorridas entre os grupos, considerando o nível de significância de 5%. Os resultados demonstraram nas crianças com FLPU, um efeito retrusivo maxilar, pela menor dimensão linear I-CC e I-MM. Também um menor crescimento maxilar transversal anterior (C-C) e menores dimensões oblíquas anteriores direita (I-C) e esquerda(I-C) e oblíquas antero-posteriores (I-M e I-M). Pela avaliação das áreas maxilares, verificou-se uma menor área total e parcial anterior no grupo FLPU, comprovando que a retrusão maxilar ocorre preponderante na região da pré maxila. Um maior crescimento mandibular tanto pelas maiores medidas lineares transversal anterior (C-C), como pelas maiores medidas (I.C-C e I.M-M), além de maior área total e parcial posterior, comprovando a tendência de crescimento protrusivo inferior. Pela sobreposição de medidas de área total maxilo-mandibulares, constatou-se a restrição do crescimento maxilar e um excesso de crescimento mandibular no grupo FLPU. A comparação entre as medidas dos lados com e sem no grupo FLPU, permitiu verificar que na maxila, as medidas anterior e total do lado sem fissura são maiores do que as do lado com fissura. Na mandíbula, as medidas posterior (O.C-M ) e antero-posterior (O. I-M) foram maiores do lado sem fissura. Na avaliação da simetria entre os lados, o grupo FLPU demonstrou, na mandíbula, assimetria estatisticamente significante para maior do lado oposto à fissura maxilar. Isso permite denotar diferenças no crescimento latero-lateral pós cirurgias de queiloplastia e de palatoplastia na maxila e na mandíbula de crianças com FLPU, aos cinco anos de idade. Conclusão: Pode-se contabilizar alterações no crescimento de crianças com FLPU operadas, aos cinco anos de idade. Representado por: 1) Uma retrusão maxilar, dado pela menor área parcial anterior (AMaxA)(p<0,001). 2) Uma protrusão mandibular, pela maior área parcial posterior (AMandP)(p<0,001). 3) Um crescimento assimétrico maxilar, maior do lado com fissura. 4) Um significante crescimento assimétrico mandibular, mais acentuado no lado contrário à fissura (p<0,001 para C-M e para I-M). / The objective of this study was to perform an evaluation of the total and partial areas and linear, transverse, longitudinal and oblique measurements of the dental arches of children with cleft lip and unilateral palate (FLPU) at five years of age. The sample consisted of 60 digital models of maxilla and mandible of children with FLPU (p = 30) (Group 1) and patients without fissure (p = 30) (Group 2). Gypsum models were scanned using Scanner 3 Shape\'s R700TM. The measurements of the dimensions of the dental arches were: linear (C-C \') and (M-M\'), linear (I-2MD), (I-2ME) and perpendicular I-MM \') by Software Appliance Designer. The measurements of the total and partial areas of the dental arches in the study groups were scored and evaluated by the Software of the Stereophotogrammetry System. For the analysis of the results the Test t was applied to verify the changes that occurred between the groups. The level of significance of 5% was considered. The results showed in children with FLPU, a maxillary retrusive effect, by the smaller linear dimension I-CC \'and I-MM\'. Also lower anterior transverse maxillary growth (C-C \') and smaller anterior oblique dimensions (IC) and left anterior (I-C\') and oblique antero-posterior anterior. (I-M and I-M \'). By the evaluation of the maxillary areas, there was a smaller total and partial anterior area in the FLPU group, proving that maxillary retrusion preponderates in the premax region. A higher mandibular growth was observed in both the greater anterior (C-C \') linear measurements and the larger measures (IC-C\' and IM-M \'), as well as a larger posterior and partial area, denoting the protrusive growth tendency overlapping of maxillomandibular total area measurements, the restriction of maxillary growth and an excess of mandibular growth in the FLPU group were found. The comparison between the left and right side measurements in the FLPU group showed that in the maxilla, anterior and total measurements on the non-cleft side are greater than those on the cleft side. In the mandible, the posterior (O.C-M) and anteroposterior (O.I-M) measurements were larger on the non-cleft side. Conclusion: It was possible to denote differences in laterolateral and sagital growth after surgery of cheiloplasty and palatoplasty in the maxilla and in the mandible of children with FLPU at five years of age. Accounted by: 1) A maxillary retrusion, given by the smallest anterior partial area (AMaxA) (p <0.001). 2) A mandibular protrusion, by the largest posterior partial area (AMandP) (p <0.001). 3) Asymmetric maxillary growth, greater on the cleft side. 4) A significant asymmetric mandibular growth, more pronounced on the opposite side to the cleft (p <0.001 for CM and for I-M).
|
7 |
Precisão das técnicas de moldagem e vazamento para próteses implantossuportadasDel'Acqua, Marcelo Antonialli [UNESP] 03 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-05-03Bitstream added on 2014-06-13T19:37:32Z : No. of bitstreams: 1
delacqua_ma_me_arafo.pdf: 2803470 bytes, checksum: c3da6f0cf6b27aff80e479e792d68cd7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo... / Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below)
|
8 |
AVALIAÇÃO DAS ALTERAÇÕES TRANSVERSAIS, ÂNTEROPOSTERIORES E VERTICAIS DA MAXILA EM PACIENTES SUBMETIDOS À EXPANSÃO RÁPIDA DA MAXILA ASSISTIDA CIRURGICAMENTE / Evaluation of the transversal alterations, antero -posterior of the dental and vertical arc of the palate in patients submitted to the rapid maxillary expansion surgically assisted.Camara, Paulo Roberto Pelucio 09 March 2006 (has links)
Made available in DSpace on 2016-08-03T16:31:05Z (GMT). No. of bitstreams: 1
Abstract.pdf: 16401 bytes, checksum: 41f23edba00ea7bf9b4ed9ff57f88bac (MD5)
Previous issue date: 2006-03-09 / The present work had to purpose evaluate the alterations produced in patients submitted to the fast expansion of maxilla by means of disjunction of the palatine suture
median assisted surgically. The sample used to accomplish this study was composed of 34 pairs of models of 17 patients, being 6 of the masculine sex and 11 of the feminine
sex. For each patient were prepared 2 pairs of models obtained in different phases: T 1 initial (before the procedure pre -operations) and T 2 three month post-shutdown of the screw expansor. The device expansor used in this sample was Hyrax appliance (13mm of expansion). The adopted surgical procedure left from an osteotomy in the
lateral walls of maxilla without the involvement of the laminates Pterigoid, osteotomy of the nasal spine to the dental average line (previous incisors), separation of the palatine suture median by means of chisel and separation of nasal septum. The beginning of the activation occurred 3 days of the post-surgical being ¼ by morning and ¼ at night, the activations followed clinical criteria for the control of the expansion. The results show that there was a statistically significant expansion in the cusped, first and second
bicuspids teeth, first molar teeth and molar teeth seconds, respectively 6,03mm, 9,82mm, 8,66mm, 9,72mm and 5,67mm. Space obtained among central and lateral incisors did not show statistically significant, the obtained values were respectively: 0,40mm and 4,12mm, such values resulted from action of the alveolar fibers that resulted in a larger inclination mesial of the central incisors and, in smaller intensity, of the lateral incisors. Evaluated the effects of the entry examinations inclinations were noted that in the first molar teeth met itself statistically significant values, being 6,890 right sides and 9,560 sides on an average left. For the first premolar teeth the obtained values were 3,260 to the side right, which was considered statistically not significant and 4,740 to the side left statistically significant. Evaluating the length of the arc to maxilar, an average reduction between 28,20mm analyzed intervals T1 mm and T2 26,56 mm
was observed varying - 1,64mm. We can conclude that the ERM-AC produced an expansion to maxila with inclination initial of the crowns of posterior teeth and reduction
in the length of the arc to maxila, the other analyzed variable had not statistically showed significant alterations in the measured intervals. e can conclude that the RMESA produced an expansion to maxilar with inclination initial of the crowns of
posterior teeth and reduction in the length of the arc to maxilar, the other analyzed variable had not statistically showed significant alterations in the measured intervals. / O presente trabalho teve por finalidade avaliar as alterações produzidas nos arcos dentárias superiores de pacientes submetidos à expansão rápida da maxila por meio de disjunção da sutura palatina mediana assistida cirurgicamente ERM-AC. A
amostra utilizada para a realização deste estudo foi composta de 34 pares de modelos de gesso de 17 pacientes, sendo 6 do sexo masculino e 11 do sexo feminino. Para cada paciente foram preparados 2 pares de modelos obtidos em diferentes fases: inicial ,antes do procedimento operatório (T1) e três meses após o travamento do parafuso expansor (T2). O dispositivo expansor utilizado nesta amostra foi o disjuntor
tipo Hyrax. O procedimento cirúrgico adotado foi a osteotomia nas paredes laterais da maxila sem o envolvimento da lâmina pterigóide, osteotomia da espinha nasal à linha média dental (incisivos centrais anteriores), separação da sutura palatina mediana por meio de cinzel e separação do septo nasal. O início da ativação ocorreu no 3o dia pós operatório sendo ¼ pela manhã e ¼ à noite, as ativações seguiram critérios clínicos para o controle da expansão. As medidas foram realizadas por meio da máquina de medição tridimensional (SAC) baseado nas alterações nos três planos vertical, sagital e transversal que ocorreram nos modelos de gesso. Os resultados mostraram que houve uma expansão estatisticamente significante na região dos caninos, primeiros prémolares, primeiros molares e segundos molares, respectivamente 6,03mm, 9,82mm, 8,66mm, 9,72mm e 5,67mm. As distâncias obtidas entre os incisivos centrais e laterais não se mostraram estatisticamente significantes, os valores obtidos foram respectivamente: 0,40mm e 4,12mm. As inclinações das coroas dentais para vestibular mostraram um comportamento assimétrico, pois nos primeiros molares os valores encontrados foram 6,890 (lado direito) e 9,560 (lado esquerdo) e para os primeiros prémolares os valores obtidos foram 3,260 para o lado direito (estatisticamente não
significante) e 4,740 para o lado esquerdo. Avaliando a variável comprimento do arco maxilar, foi observada uma diminuição média entre os intervalos analisados T1 28,20 mm e T2 26,56 mm variando 1,64mm. Podemos concluir que a ERM-AC produziu uma expansão maxilar com inclinação vestibular da coroas dos dentes posteriores e diminuição no comprimento do arco maxilar, as outras variáveis analisadas não mostraram alterações estatisticamente significantes nos intervalos medidos.
|
9 |
AVALIAÇÃO POR MEIO DE MODELOS DE GESSO DAS ALTERAÇÕES DENTOESQUELÉTICAS, PROMOVIDAS PELA EXPANSÃO RÁPIDA DA MAXILA ASSISTIDA CIRURGICAMENTE (ERMAC)Marques, Ricardo Moreira 21 March 2007 (has links)
Made available in DSpace on 2016-08-03T16:31:08Z (GMT). No. of bitstreams: 1
Ricardo.pdf: 2029591 bytes, checksum: dcbf7ada9131ef0b69a9c7b6106d08e2 (MD5)
Previous issue date: 2007-03-21 / This study evaluated the alterations produced in the superior dental arcs of patients submitted to the Surgically Assisted Rapid Maxillary Expansion (SARME). The sample was composed of 50 orthodontic superior models of 18 patients (six males
and 12 females. The average age was 23,3 years. For each patient three orthodontic models had been prepared in different phases: initial, pre-operative stage (T1), three
months after expansion (expander locking) and removal of Hyrax expander appliance, and adaptation of acrylic plate for contention (T2), six months of postexpansion
and acrylic plate removal period (T3). The appliance used in this study was the Hyrax type. The adopted surgical procedure was the lateral osteotomy of the
maxilla, without involving the pterygoid plate, osteotomy from the nasal spine to the maxillary dental midline (superior central incisor), the midpalatal suture separation
with a chisel and the separation of nasal septum also. The activation initiated on the third day postoperative , being one-quarter turn in the morning and one-quarter turn in
the night. The activations had followed clinical criteria for the control of the expansion. The measures had been carried out through the machine of threedimensional measurement (SAC), based on the alterations in the three plans (vertical, sagittal and transversal) occurred in the orthodontic models. Conclusions: 1) There were statistically significant increase in the transversal distances in all the teeth groups (from central incisors to second molars) of T1 for T2, demonstrating the
effectiveness of the treatment. The variables did not show statistically significant difference of T2 for T3, indicating stability after six months following the SARME; 2)
There were a statistically significant increase in the inclinations of the first and the second molar of right and left sides, and the second premolar of the left side only,
suggesting a anti-symmetrical behavior of evaluated teeth; 3) There were an increase in the palatine width in the analyzed intervals, with statistically significant differences
between T1 x T2 and T1 x T3; 4) Statistically significant differences were not observed in the pala tine depth in the analyzed intervals.(AU) / Este estudo avaliou as alterações produzidas nos arcos dentais superiores de pacientes submetidos à Expansão Rápida da Maxila Assistida Cirurgicamente (ERMAC). A amostra utilizada foi composta de 50 modelos de gesso superiores de
18 pacientes, sendo seis do sexo masculino e 12 do sexo feminino, com média de idade de 23,3 anos. Para cada paciente foram preparados três modelos de gesso
obtidos em diferentes fases: Inicial, antes do procedimento operatório (T1); três meses pós-expansão (travamento do expansor) e momento da remoção do aparelho
expansor tipo Hyrax e colocação da placa removível de acrílico para contenção (T2); seis meses pós-expansão e momento de remoção da placa de acrílico (T3). O
dispositivo expansor utilizado foi o disjuntor tipo Hyrax. O procedimento cirúrgico adotado foi a osteotomia lateral da maxila sem o envolvimento da lâmina pterigóide,
osteotomia da espinha nasal à linha média dental (incisivos centrais superiores), separação da sutura palatina mediana por meio de cinzel e separação do septo
nasal. O início da ativação ocorreu no terceiro dia pós-operatório, sendo ¼ de volta pela manhã e ¼ à noite, sendo que as ativações seguiram critérios clínicos para o
controle da expansão. As medidas foram realizadas por meio da máquina de medição tridimensional (SAC), baseando-se nas alterações nos três planos (vertical, sagital e transversal) que ocorreram nos modelos de gesso. Concluiu-se que:
1. Houve um aumento estatisticamente significante nas distâncias transversais em todos os grupos de dentes (de incisivos centrais até segundos molares) de T1 para
T2, demonstrando a efetividade do tratamento. De T2 para T3 não houve diferença estatisticamente significante para nenhuma variável, indicando, assim, estabilidade
após seis meses do término da ERMAC; 2. Houve um aumento estatisticamente significante nas inclinações dos primeiros e segundos molares dos lados direito e esquerdo e dos segundos pré-molares apenas do lado esquerdo, sugerindo um
comportamento assimétrico dos dentes avaliados; 3. Houve um aumento na largura palatina nos intervalos analisados, com diferenças estatisticamente significantes
entre T1 x T2 e T1 x T3; 4. Não foram observadas diferenças estatisticamente significantes na profundidade palatina nos intervalos analisados.(AU)
|
10 |
Dos modelos de gesso ás imagens tridimensionaisGallão, Simone [UNESP] 13 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:22Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-09-13Bitstream added on 2014-06-13T19:44:07Z : No. of bitstreams: 1
gallao_s_dr_arafo.pdf: 1124962 bytes, checksum: d992196fadc340d0f4d06befe7cd817a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta pesquisa foi desenvolvida em três estudos que tiveram como objetivos: pesquisar a presença de bactérias e fungos em modelos de gesso; avaliar a precisão e a reprodutibilidade de medidas dentárias lineares em modelos de gesso originais e duplicados utilizando paquímetro digital e em modelos digitais medidos com o Software Brasileiro O3d e; correlacionar medidas faciais, em indivíduos leucodermas, de 12 a 17 anos, com medidas transversas das arcadas em oclusão normal e avaliar diferenças entre os gêneros. Da amostra total de 78 pares de modelos, foram utilizados 44 pares de modelos de gesso para o primeiro estudo, armazenados desde os anos 1980 e 1981. O material para a pesquisa de micro-organismos foi colhido com auxílio de swab e semeado em culturas de Infusão de Cérebro-Coração (BHI) e Caldo Sabouraud Glicose para posterior plaqueamento e identificação das colônias. Para o segundo estudo outros 34 pares de modelos de gesso foram selecionados, preenchendo os seguintes requisitos de inclusão: presença de todos os dentes permanentes de 1° molar a 1° molar; oclusão normal; sem coroas protéticas; nenhum tratamento ortodôntico prévio; apinhamentos ou espaçamentos menores ou iguais a 2 milímetros. Os modelos originais e os duplicados foram medidos com paquímetro digital (Digimess®). Os modelos de gesso duplicados foram escaneados a laser e medidos pelo Sistema O3d (Widialabs®). Dos modelos utilizados no segundo, foram selecionados 21 pares de modelos de gesso para o terceiro estudo, por apresentarem medidas cefalométricas que foram consultadas e tabuladas. No primeiro estudo ocorreu, em 25% dos modelos, crescimento bacteriano de Estafilococos coagulase negativa; Micrococcus sp.; Bacillus sp. e bacilos gram-negativos não fermentadores e, em 5,7%, crescimento fúngico de Cladophialophora sp.; Trichosporon beigelii; Aspergillus flavus e Aureobasidium pullulans... / This research was developed in three studies that had as objectives: search the presence of bacteria and fungi on dental models.; evaluate the accuracy and reproducibility of linear dental measures in original and duplicated gypsum models using digital caliper and in digital models measured by O3d Brazilian Software and correlate facial measures, in Caucasian individuals, between 12 and 17 years old, with transverse measures of normal occlusion arches and evaluate gender differences. From the original sample of 78 pairs of models, 44 pairs of dental models stored since 1980 and 1981 were used for the first study. The material for the microbiological search was collected with swab and cultivated in Brain-Heart Infusion cultures (BHI) and Sabouraud Dextrose Broth for subsequent plating and colonies identification. For the second study 34 pairs of dental models were selected following the inclusion requirements: presence of all the permanent teeth from 1st molar to 1st molar; normal occlusion; with no prosthetic crowns; no previous orthodontic treatment; 2 millimeters or less crowdings or smaller spacings. The original and the duplicated models were measured with digital caliper (Digimess™). The duplicated dental models were laser scanned and measured by O3d software (Widialabs™). From the models used for the second study 21 pairs of gypsum models were selected for the third study, because they had cephalometric measures that were consulted and tabbed. In the first study happened, in 25% of the models, bacterial growth of coagulase-negative Staphylococcus; Micrococcus sp.; Bacillus sp. and nonfermenting Gram-negative bacillus and, in 5,7%, fungal growth of Cladophialophora sp.; Trichosporon beigelii; Aspergillus flavus and Aureobasidium pullulans. So, it’s important that the dentist avoid crossed contamination and the digital models technology can avoid to store dental... (Complete abstract click electronic access below)
|
Page generated in 0.0508 seconds