• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 17
  • 17
  • 17
  • 16
  • 14
  • 14
  • 10
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação in vitro da precisão de três técnicas para moldagem do arco superior parcialmente edentado / Evaluation in vitro of the accuracy of three impression techniques for the partially edentulous upper arch

Bueno Junior, Eliseu Antonio 29 September 2005 (has links)
Este estudo serviu ao objetivo de avaliar a capacidade de reprodução da região do palato e o posicionamento de pilares em modelos de gesso de um arco superior parcialmente edentado, obtidos a partir de três técnicas de moldagem: 1) alginato em moldeira de estoque - AL; 2) pasta zincoeugenólica em moldeira individual, seguida de sobremoldagem com alginato em moldeira de estoque - MS e 3) silicone de condensação em moldeira de estoque pela técnica da dupla moldagem ou do reembasamento - SC. Os modelos de gesso testados foram obtidos a partir de moldagens executadas sobre modelo padrão metálico. Pontos representativos do perfil palatino, a distância relativa entre os pilares, bem como suas inclinações, foram mensurados com um aparelho de medição tridimensional de coordenadas e analisados quanto à sua fidedignidade em relação à morfologia do modelo padrão. Os resultados demonstraram que: 1) ocorreram distorções verticais positivas e negativas nos modelos produzidos pelas três técnicas, sendo que a técnica SC apresentou as maiores variações, predominantemente negativas, produzindo modelos com palato mais profundo quando comparados àqueles obtidos pelas técnicas M e A; 2) foram observadas distorções horizontais positivas e negativas nos modelos produzidos pelas três técnicas, com tendência de aumento das distâncias inter-pilares para as técnicas AL e SC e de encurtamento para a técnica MS; 3) os desvios angulares foram inexpressivos no comprometimento da inclinação axial dos pilares quando considerada a estabilização da estrutura metálica de uma prótese removível; 4) as distorções verificadas com as três técnicas estudadas estão dentro dos parâmetros de aceitabilidade clínica estabelecidos neste trabalho. / The objective of this study was to evaluate the reproduction potential of the palate area and the position of abutments in partially edentulous, upper stone casts produced with three impressions techniques: 1) irreversible hydrocolloid in stock tray - AL; 2) zinc oxide-eugenol paste in a custom tray with a pick-up impression of irreversible hydrocolloid - MS and 3) putty-wash condensation silicone in stock tray - SC. Representative points on the palatal surface and the relative distance between the abutments as well their inclination were measured with a three-dimensional coordinate measurement equipment and the data used to analyze the fidelity of the casts in relation to the original metal model. The results showed: 1) positive and negative vertical discrepancies on casts made from all impression techniques, with SC responsible for the highest variations (predominantly negatives) that rendered casts with a deeper palatal vault when compared to those obtained with AL and MS; 2) positive and negative horizontal discrepancies on casts produced from all impression techniques, with AL and SC tending to increase the distances between supports while MS seemed to decrease these distances; 3) the angular deviations observed represented no substantial compromise to the axial inclination of the abutment when considering the stability of the removable prosthesis framework; 4) the discrepancies evidenced with the three techniques were within the benchmark values for clinical acceptability initially established.
2

Pode a seleção da técnica ser superior ao material escolhido para a união de transferentes? / Can the selection of the technique be superior to the material selected for the splint of transferents?

Mariotto, Guilherme de Aguiar 27 March 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2019-03-12T21:59:27Z No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2019-03-12T21:59:27Z (GMT). No. of bitstreams: 2 Guilherme_Mariotto_2018.pdf: 1557188 bytes, checksum: a9d67c335a6fbbe03d061239156c3baf (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-27 / STATEMANT OF PROBLEM: The splint transfer technique in implant impression can result in misfit on prosthetic structures. PURPOSE: To evaluate the linear dimensional change of polymerization from 3 materials and 2 techniques of splint transfer technique for implant prostheses used in the open tray technique. MATERIAL AND METHODS: Two implants were installed in a nylon mastermodel whith the shape of a upperjaw, over this two implants, miruscone were tapered. Open tray transfer impression coppings were coupled in to the miruscone, and a silicone guide was made standardizing the unions between the transfers. The samples were divided in six groups (n=20): autopolymerizing acrylic resin Pattern Resin (PA) and Durallay (DU), and bis-acrylic resin Protemp4 (BI), with single step and sectioning and bonding segments techniques (PAC, DUC, BIC). The values of linear dimensional change between these transfers were measured in a profile projector (VB300; Starret) coupled to the Quadra Check apparatus, with a measurement capacity of 0.001 mm, performed by a calibrated single operator. Data were submitted to factorial ANOVA, two-way: Materials and technique (p <0.01) RESULTS: Statistically significant results were found in all comparisons. The PA resin presented the smallest values (μm) of linear dimensional change, both in the single-step technique and in the section and conding, in the following order: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). The single-step technique obtained worse results regardless of the material. CONCLUSIONS: The sectioning and bonding technique reduced the dimensional change of the samples in all materials, and the Pattern Resin LS presented the lowest contraction, followed by Durallay and Protemp4. CLINICAL IMPLICATIONS: For the transfer splintage in implant prothesis the choice of technique seems to be more importante than the selection of the material to get fidelity of the models / DECLARAÇÃO DO PROBLEMA: A técnica de união entre os transferentes de moldagem para próteses sobre implantes pode resultar em desadaptações nas infraestruturas protéticas. OBJETIVOS: Avaliar a alteração dimensional linear de polimerização de 3 materiais e 2 técnicas de união de transferentes de moldagem para próteses sobre implantes utilizados na técnica da moldeira aberta. MATERIAL E MÉTODOS: Foi confeccionada uma matriz em forma de maxila em nylon, instalados dois implantes osseointegráveis e, sobre esses dois, minipilares cônicos retos. Transferentes de moldagem de moldeira aberta foram acoplados aos minipilares, e uma guia de silicone foi confeccionada padronizando as uniões entre transferentes. As amostras foram divididas em seis grupos (n=20): resinas acrílicas quimicoativadas Pattern Resin (PA) e Durallay (DU), e resina bisacrílica Protemp4 (BI), com as técnicas passo único e secção e união dos segmentos (PAC, DUC, BIC). Os valores de alteração dimensional linear ocorridos entre esses transferentes foram mensurados em projetor de perfil (VB300; Starret) acoplado ao aparelho Quadra Check, com capacidade de mensuração de 0.001 mm, realizado por único operador calibrado. Os dados foram submetidos ao teste de ANOVA fatorial, two-way: Materiais e técnica (p<0,01). RESULTADOS: Foram encontrados resultados estatisticamente significantes em todas as comparações. A resina PA apresentou os menores valores (μm) de alteração dimensional linear, tanto na técnica de passo único, quanto na técnica de secção e união, na seguinte ordem: BI 255.73(+3.81), DU 173.75(+2.30), PA 95.97(+3.20), BIC 23.82(+1.71), DUC 20.85(+2.53), PAC 13.27(+2.09). A técnica de passo único obteve piores resultados independente do material. CONCLUSÕES: A técnica de secção e união reduziu a alteração dimensional das amostras em todos os materiais, e a resina Pattern Resin LS apresentou a menor contração, seguida pela Durallay e Protemp4. IMPLICAÇÕES CLÍNICAS: Para a união de transferentes em próteses sobre implantes a escolha da técnica de união parece ser mais importante do que a seleção do material para a obtenção de maior fidelidade dos modelos.
3

Influência de técnicas e materiais de moldagem na precisão de modelos de trabalho obtidos para a confecção de prótese fixa convencional e sobre implante / Influence of techniques and impression materials on the accuracy of working casts obtained for the confection of conventional and implant-supported fixed prosthesis

Vargas, Fernando Fernandes 20 February 2017 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-07-14T11:46:02Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência de técnicas e materiais de moldagem na precisão de modelos de.pdf: 759210 bytes, checksum: 1bd252ce92c5a18682ec4a9120348f75 (MD5) / Made available in DSpace on 2017-07-14T11:46:02Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Influência de técnicas e materiais de moldagem na precisão de modelos de.pdf: 759210 bytes, checksum: 1bd252ce92c5a18682ec4a9120348f75 (MD5) Previous issue date: 2017-02-20 / Sem bolsa / De acordo com a literatura, os materiais de moldagem disponíveis no mercado sofrem alteração dimensional após sua presa. Essa distorção pode afetar a precisão e, consequentemente, a adaptação final de próteses parciais fixas convencionais e sobre implantes. O objetivo do presente estudo foi de investigar e comparar, através do uso de escaneamento tridimensional e software de comparação de superfícies, as alterações tridimensionais decorrentes do procedimento de moldagem e obtenção de modelos de trabalho utilizando diferentes materiais e técnicas de moldagem comumente usadas na prática odontológica. Um modelo mestre para dentes contendo um incisivo central e um canino superiores preparados para receber prótese fixa de três elementos livre de metal e outro modelo contendo dois análogos de implantes com conexão hexagonal externa foram obtidos. Os grupos (n=5) foram divididos de acordo com a técnica (dupla mistura, moldagem única e com casquete para dentes e direta e indireta para implantes) e material de moldagem (silicone de adição, silicone de condensação e poliéter). A avaliação e comparação das superfícies com o modelo mestre foram realizadas através de escaneamento 3-D (S600 ARTI, Zirkonzahn) e software de análises específico (Geomagic Qualify v.13, Geomagic Inc). Os resultados obtidos foram submetidos à análise estatística que demonstrou não haver diferença significante entre as técnicas de moldagem tanto para dentes quanto para implantes; porém, no caso dos materiais de moldagem, os modelos de trabalho obtidos à partir de moldagens com silicone de condensação apresentaram menor distorção que os modelos obtidos com os demais materiais. Entretanto, os valores de variação foram bastante pequenos e talvez não apresentem significância clínica. Baseado no que foi exposto, pode-se concluir que o cirurgião-dentista deve escolher a técnica e o material que considera mais apto a utilizar em moldagem para próteses fixas, tanto sobre dentes quanto sobre implantes. / According to the literature, all the available impression materials on the market deform after its polymerization. This distortion can affect the precision and, consequently, the marginal fit of fixed partial dentures on teeth or implants. The aim of this study was to investigate and compare, through the use of three-dimensional scanning and surface comparison software, the dimensional changes of working cast originated from different impression techniques and materials commonly used on the dental practice.. Master casts containing a maxillary central incisor and a canine prepared to receive a three-unit metal-free fixed partial denture and two external hex implant analogues were made. Groups (n=5) were divided according to the technique (dual mixture, single impression and custom tray for teeth; and direct or indirect for implants), and impression material (polyvinyl siloxane, polydimethylsiloxane and polyether). Evaluation and comparison of the surfaces between master cast and specimens were performed with a fully automated optical structured-light scanner (S600 ARTI, Zirkonzahn) and Geomagic Qualify v.13 (Geomagic Inc.) software inspection tool. The obtained results were submitted to statistical analysis, which showed that there was no significant difference between the impression techniques for both teeth and implants groups; however, in regard of impression materials, working casts obtained by polydimethylsiloxane impressions showed lower volumetric distortion than casts obtained with the other impression materials. However, the distortion values were very small and may not be clinically significant. Based on the above, it can be concluded that the dentist could choose the impression technique and material that he considers most suitable for fixed prostheses teeth or implant-borne prostheses .
4

Precisão das técnicas de moldagem e vazamento para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 03 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-05-03Bitstream added on 2014-06-13T19:37:32Z : No. of bitstreams: 1 delacqua_ma_me_arafo.pdf: 2803470 bytes, checksum: c3da6f0cf6b27aff80e479e792d68cd7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo... / Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below)
5

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados

Munhoz Cháves, Alejandro [UNESP] 17 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-17Bitstream added on 2014-06-13T21:06:54Z : No. of bitstreams: 1 munozchavez_a_dr_arafo.pdf: 2735655 bytes, checksum: 57a4aa3a7ba468631481a08da1143c06 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que:... / An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material.
6

Precisão das técnicas de moldagem para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 08 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-08Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 delacqua_ma_dr_arafo.pdf: 1398989 bytes, checksum: 17374b239dcb2b543aaaa9731517a5ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... / Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group’s measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below)
7

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four / In vitro analysis of the accuracy of splinting impression techniques using all-on-four system

Pimentel, Gustavo Henrique Diniz [UNESP] 15 October 2014 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-15. Added 1 bitstream(s) on 2016-12-09T13:55:26Z : No. of bitstreams: 1 000874738.pdf: 3429941 bytes, checksum: f0746f3294aca82e94682f551d6b7ae5 (MD5) / O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar in vitro a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema All-on-four). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate in vitro the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating All-on-four system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below)
8

Análise in vitro da precisão de técnicas de esplintagem na moldagem de implantes no esquema all-on-four /

Pimentel, Gustavo Henrique Diniz. January 2014 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Marco Antônio Compagnoni / Banca: Janaína Habib Jorge / Banca: Estevam Augusto Bonfante / Banca: Ricardo Faria Ribeiro / Resumo: O assentamento passivo de próteses sobre implantes é fundamental para que o sucesso da reabilitação seja alcançado. A precisão na moldagem de transferência é um dos principais fatores responsáveis por assegurar a adaptação dos componentes. Dentre as várias técnicas propostas, não existe consenso sobre qual é a mais eficaz. O objetivo do presente estudo foi avaliar "in vitro" a precisão de diferentes métodos de união de transferentes quadrados na moldagem de implantes paralelos e angulados instalados em curva. Para a obtenção do modelo mestre, matrizes metálicas em alumínio foram confeccionadas, apresentando quatro perfurações, em forma de curva, paralelas (prótese protocolo convencional) e anguladas (esquema "All-on-four"). Foram fixados os análogos e, sobre eles, foram confeccionadas estruturas metálicas. Para os implantes retos, os grupos foram divididos em GSU-R: transferentes quadrados sem união; GUR-R: transferentes quadrados unidos com bastões de resina acrílica autopolimerizável pré-fabricados e GUM-R: transferentes quadrados unidos com haste metálica, cianoacrilato e resina acrílica autopolimerizável. Para os implantes angulados, as mesmas técnicas foram comparadas: GSU-A, GUR-A, GUM-A. A moldagem foi realizada com silicone de adição e moldeira rosqueada para controlar variáveis. Os modelos foram vazados em matriz padronizada com gesso pedra tipo IV. Os modelos obtidos foram armazenados à temperatura ambiente por no mínimo 120 horas até que as medidas das fendas fossem realizadas. Foi utilizada uma lupa LEICA acoplada a uma câmera de vídeo colorida e as mensurações das fendas foram realizadas no programa LEICA QWin. Foi aplicado o teste de Kruskal-Wallis, complementando pelo teste de Dunn, com nível de significância de 5%. Para os implantes retos, foi observada diferença estatisticamente significante entre os grupos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Passively fitting superstructures are a prerequisite for long-lasting osseointegration of dental implants. Accurate transfer of the implant positions from the mouth to a definitive stone cast is a crucial step for ensuring the adaptation of components. Among the various techniques proposed, there is no consensus on which one is the most effective. The aim of this study was to evaluate "in vitro" the accuracy of different splinting methods in the impression of implants under standardized laboratory conditions. To obtain the master model, an aluminum metal matrix was developed, presenting four perforations, parallel (simulating conventional prosthesis and angled (simulating "All-on-four" system). Analogs were fixed and, on them, metal structures were fabricated. For straight implants, the groups were divided into GSUR: non-splinted square transfers; GUR-R: transfers splinted acrylic resin; GUM R: transfers splinted with metal rod, cyanoacrylate and acrylic resin. For angled implants, the same techniques were compared: GSU-A, GUR-A, GUM-A. The impression was performed with polyvinyl siloxane impression material and a standardized tray to control variables. The models were cast in standardized matrix with type IV plaster stone. For the measurements, a software (Leica QWin) received the images from a video camera coupled to a Leica stereomicroscope. The KruskalWallis test, associated with Dunn's test, with significance level of 5%, was applied. For straight implants, statistically significant difference between groups (KruskalWallis test; p <0.001) was observed. The difference was between GUR-R (186.71 µm) and master model (110.40 µm) and between GUR-R and the other groups (GSU-R: 108.27 µm and GUM-R: 92.98 µm). For angled implants, no statistically significant difference (p = 0.492) was found between the groups (MM-A: 68.52 µm; GSU-A: 60.80 µm; GUR-A: 56.54 µm; GUM-A: 69.33 µm. ..(Complete abstract electronic access below) / Doutor
9

Avaliação in vitro da precisão de três técnicas para moldagem do arco superior parcialmente edentado / Evaluation in vitro of the accuracy of three impression techniques for the partially edentulous upper arch

Eliseu Antonio Bueno Junior 29 September 2005 (has links)
Este estudo serviu ao objetivo de avaliar a capacidade de reprodução da região do palato e o posicionamento de pilares em modelos de gesso de um arco superior parcialmente edentado, obtidos a partir de três técnicas de moldagem: 1) alginato em moldeira de estoque - AL; 2) pasta zincoeugenólica em moldeira individual, seguida de sobremoldagem com alginato em moldeira de estoque - MS e 3) silicone de condensação em moldeira de estoque pela técnica da dupla moldagem ou do reembasamento - SC. Os modelos de gesso testados foram obtidos a partir de moldagens executadas sobre modelo padrão metálico. Pontos representativos do perfil palatino, a distância relativa entre os pilares, bem como suas inclinações, foram mensurados com um aparelho de medição tridimensional de coordenadas e analisados quanto à sua fidedignidade em relação à morfologia do modelo padrão. Os resultados demonstraram que: 1) ocorreram distorções verticais positivas e negativas nos modelos produzidos pelas três técnicas, sendo que a técnica SC apresentou as maiores variações, predominantemente negativas, produzindo modelos com palato mais profundo quando comparados àqueles obtidos pelas técnicas M e A; 2) foram observadas distorções horizontais positivas e negativas nos modelos produzidos pelas três técnicas, com tendência de aumento das distâncias inter-pilares para as técnicas AL e SC e de encurtamento para a técnica MS; 3) os desvios angulares foram inexpressivos no comprometimento da inclinação axial dos pilares quando considerada a estabilização da estrutura metálica de uma prótese removível; 4) as distorções verificadas com as três técnicas estudadas estão dentro dos parâmetros de aceitabilidade clínica estabelecidos neste trabalho. / The objective of this study was to evaluate the reproduction potential of the palate area and the position of abutments in partially edentulous, upper stone casts produced with three impressions techniques: 1) irreversible hydrocolloid in stock tray - AL; 2) zinc oxide-eugenol paste in a custom tray with a pick-up impression of irreversible hydrocolloid - MS and 3) putty-wash condensation silicone in stock tray - SC. Representative points on the palatal surface and the relative distance between the abutments as well their inclination were measured with a three-dimensional coordinate measurement equipment and the data used to analyze the fidelity of the casts in relation to the original metal model. The results showed: 1) positive and negative vertical discrepancies on casts made from all impression techniques, with SC responsible for the highest variations (predominantly negatives) that rendered casts with a deeper palatal vault when compared to those obtained with AL and MS; 2) positive and negative horizontal discrepancies on casts produced from all impression techniques, with AL and SC tending to increase the distances between supports while MS seemed to decrease these distances; 3) the angular deviations observed represented no substantial compromise to the axial inclination of the abutment when considering the stability of the removable prosthesis framework; 4) the discrepancies evidenced with the three techniques were within the benchmark values for clinical acceptability initially established.
10

Avaliação bidimensional e tridimensional na adaptação marginal de retentor metálico fundido e coping; obtidos por um novo protocolo com moldagem única /

Sichi, Luigi Giovanni Bernardo. January 2019 (has links)
Orientador: Rodrigo Máximo de Araújo / Coorientadora: Samia Carolina Mota Cavalcanti Sacorague / Banca: Paula Carolina Komori de Carvalho / Banca: Fernanda de Cássia Papaiz Gonçalves / Resumo: A otimização do tempo reabilitador é um benefício direto a saúde do paciente, pois previne o mesmo do contato com possíveis contaminações e ambientes que lhe causem estresse. Isso pode ser viabilizado pelo desenvolvimento de técnicas que diminuam etapas de execução de um determinado tratamento. Pensando nisso, esse trabalho tem por objetivo avaliar a desadaptação marginal de copings em liga de cobalto-cromo (Co-Cr) através da técnica da réplica de silicone (2D) e avaliação por varredura digital (3D), em 24 dentes humanos unirradiculares, com retentores intraradiculares (RIR) em Co-Cr, cimentados com cimento de fosfato de zinco. Divididos em dois grupos, ambos com término marginal em ombro 130º: grupo A obtidos pelo método convencional, com execução de RIR primeiro, para depois coping com retentor já cimentado e grupo B de moldagem única para obtenção de RIR e coping. Os resultados foram submetidos a uma análise do teste t e de variância ANOVA. A técnica da réplica de silicone, demonstrou as seguintes médias de valores marginais: 83,77±51,84μm (grupo A) e 77,09±31,65μm (grupo B) p=0,4477 E a varredura digital, os resultados positivos revelaram que as médias de todas as superfícies encontraram-se acima de 50 μm; e os negativos: revelaram que as médias encontraram-se abaixo de 100 μm. Este estudo concluiu que é possível obter RIR e coping através de moldagem única / Abstract: The optimization of the clinical appointment is a direct benefit to the health of the patient, because prevents it from the contact with possible contaminations and environments that cause stress. This can be possible by the development of techniques that may decrease the execution stages of a treatment. With this in mind, the aims of this study is to investigate the marginal adaptation of Cobalt-Chromium alloy (Co-Cr) copings through silicone replica technique (2D) and digital evaluation (3D) in 24 human single rooted teeth with post-and-core in Co-Cr, cemented with zinc phosphate. Divided in to two groups, both having shoulder 130 degrees as marginal type: group A by the conventional method, impression and cementation of Co-Cr post-and-core first and then impression for the coping and group B single impression for coping and post and core. The results were analyzed by test t and one-way ANOVA. The silicone replica technique showed the following mean marginal values: 83.77 ± 51.84 μm (group A) and 77.09 ± 31, 65 μm (group B) p= 0,4477. The digital protocol, in the positive results revealed that the averages of all surfaces were above 50 μm; and the negatives: revealed that the averages were below 100 μm. This study concluded that it is possible to obtain post-and-core and coping through a single impression technique / Mestre

Page generated in 0.4784 seconds