• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 2
  • Tagged with
  • 33
  • 33
  • 29
  • 26
  • 12
  • 11
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Minimplante e botão lingual como ancoragem para retração inicial de caninos superiores: estudo prospectivo

Arantes, Flávia de Moraes [UNESP] 29 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-29Bitstream added on 2014-06-13T21:05:59Z : No. of bitstreams: 1 arantes_fm_dr_araca.pdf: 917045 bytes, checksum: 35b80ca88f794114ea01fe8fe638b23f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A preocupação com a ancoragem é um dos principais fatores a serem considerados no planejamento de um tratamento ortodôntico. Entendem-se como ancoragem os procedimentos intra e extrabucal em que um ou mais dentes ou dispositivos ortodônticos são utilizados como apoio para movimentar outros dentes. A utilização mais frequente dos implantes decorre de uma menor colaboração do paciente, não prejudica a sua estética e ainda cria um sistema de forças mais definido. Por essas razões e pela utilização clínica dos minimplantes de forma indiscriminada, surgiu o interesse em estudar a perda de ancoragem relacionada aos minimplantes. O objetivo deste trabalho foi comparar, por meio de telerradiografias, panorâmicas e modelos, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. Foram selecionados 18 pacientes, divididos em dois grupos aleatórios de 9 indivíduos cada um (A e B), triados para tratamento ortodôntico na Faculdade de Odontologia de Araçatuba – UNESP, Disciplina de Ortodontia. O grupo A utilizou o minimplante enquanto o grupo B utilizou botão lingual. Para todos os pacientes foram realizadas duas telerradiografias (T1 e T2), duas panorâmicas (P1 e P2) e dois modelos (M1 e M2). Os primeiros exames complementares foram realizados ao início (T1, P1 e M1), e o outro, ao final da retração inicial de canino (T2, P2 e M2). Foi eleita a segunda fase (retração inicial de canino), devido à grande perda de ancoragem que se tem neste estágio do tratamento. Todas as medidas foram tabuladas e submetidas a análise estatística. Para comparação entre as fases Início e Após foi utilizado o teste “t” pareado. Para a comparação entre os grupos de minimplante e botão lingual foi utilizado o teste “t” de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Todos os cálculos... / The concern with the anchorage is one of the main factors to be considered when planning an orthodontic treatment. Anchorage comprehends intra and extraoral procedures in which one or more teeth or orthodontic devices are used as a support for moving other teeth. The use more constant of implants is derived from a poor patient collaboration, does not impair the esthetics and still creates more defined forces system. For these reasons and because of the mini-implants clinical utilization in an indiscriminate way, there was an increased interest in studying anchorage loss related to mini-implants. The purpose of this study was to compare, by means of teleradiographies, panoramic radiographs and models, the anchorage loss after initial maxillary canine retraction between two groups. Eighteen patients were selected, then randomly divided into two groups of 9 individuals each (A and B), and elected for orthodontic treatment in the Faculty of Dentistry of Araçatuba – UNESP, Orthodontics Department. Group A utilized mini-implant while group B utilized lingual button. For all patients, two teleradiographies (T1 and T2), two panoramic radiographs (P1 and P2) and two models (M1 and M2) were done. The first complementary exams were accomplished in the beginning (T1, P1 and M1) and the other in the end of the initial canine retraction (T2, P2, and M2). The second phase was elected (initial canine retraction) due to the great anchorage loss that exists in this treatment stage. All measurements were tabulated and submitted to statistical analysis. For the comparison between the stages “Beginning” and “After”, a paired t test was used. For the comparison between the mini-implant and lingual button groups, a Student’s t test for independent measurements was used. In all tests, a significance level of 5% (p<0,05) was adopted. All statistical calculations... (Complete abstract click electronic access below)
12

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados

Munhoz Cháves, Alejandro [UNESP] 17 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-17Bitstream added on 2014-06-13T21:06:54Z : No. of bitstreams: 1 munozchavez_a_dr_arafo.pdf: 2735655 bytes, checksum: 57a4aa3a7ba468631481a08da1143c06 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que:... / An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material.
13

Precisão das técnicas de moldagem para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 08 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-08Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 delacqua_ma_dr_arafo.pdf: 1398989 bytes, checksum: 17374b239dcb2b543aaaa9731517a5ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... / Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group’s measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below)
14

Dos modelos de gesso ás imagens tridimensionais /

Gallão, Simone. January 2010 (has links)
Orientador: Lídia Parsekian Martins / Banca: Lourdes Aparecida Matins dos Santos-Pinto / Banca: Dirceu Barnabé Raveli / Banca: Kurt Faltin Junior / Banca: Vitoria Aparecida Muglia Moscatiello / Resumo: Esta pesquisa foi desenvolvida em três estudos que tiveram como objetivos: pesquisar a presença de bactérias e fungos em modelos de gesso; avaliar a precisão e a reprodutibilidade de medidas dentárias lineares em modelos de gesso originais e duplicados utilizando paquímetro digital e em modelos digitais medidos com o Software Brasileiro O3d e; correlacionar medidas faciais, em indivíduos leucodermas, de 12 a 17 anos, com medidas transversas das arcadas em oclusão normal e avaliar diferenças entre os gêneros. Da amostra total de 78 pares de modelos, foram utilizados 44 pares de modelos de gesso para o primeiro estudo, armazenados desde os anos 1980 e 1981. O material para a pesquisa de micro-organismos foi colhido com auxílio de swab e semeado em culturas de Infusão de Cérebro-Coração (BHI) e Caldo Sabouraud Glicose para posterior plaqueamento e identificação das colônias. Para o segundo estudo outros 34 pares de modelos de gesso foram selecionados, preenchendo os seguintes requisitos de inclusão: presença de todos os dentes permanentes de 1° molar a 1° molar; oclusão normal; sem coroas protéticas; nenhum tratamento ortodôntico prévio; apinhamentos ou espaçamentos menores ou iguais a 2 milímetros. Os modelos originais e os duplicados foram medidos com paquímetro digital (Digimess®). Os modelos de gesso duplicados foram escaneados a laser e medidos pelo Sistema O3d (Widialabs®). Dos modelos utilizados no segundo, foram selecionados 21 pares de modelos de gesso para o terceiro estudo, por apresentarem medidas cefalométricas que foram consultadas e tabuladas. No primeiro estudo ocorreu, em 25% dos modelos, crescimento bacteriano de Estafilococos coagulase negativa; Micrococcus sp.; Bacillus sp. e bacilos gram-negativos não fermentadores e, em 5,7%, crescimento fúngico de Cladophialophora sp.; Trichosporon beigelii; Aspergillus flavus e Aureobasidium pullulans... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This research was developed in three studies that had as objectives: search the presence of bacteria and fungi on dental models.; evaluate the accuracy and reproducibility of linear dental measures in original and duplicated gypsum models using digital caliper and in digital models measured by O3d Brazilian Software and correlate facial measures, in Caucasian individuals, between 12 and 17 years old, with transverse measures of normal occlusion arches and evaluate gender differences. From the original sample of 78 pairs of models, 44 pairs of dental models stored since 1980 and 1981 were used for the first study. The material for the microbiological search was collected with swab and cultivated in Brain-Heart Infusion cultures (BHI) and Sabouraud Dextrose Broth for subsequent plating and colonies identification. For the second study 34 pairs of dental models were selected following the inclusion requirements: presence of all the permanent teeth from 1st molar to 1st molar; normal occlusion; with no prosthetic crowns; no previous orthodontic treatment; 2 millimeters or less crowdings or smaller spacings. The original and the duplicated models were measured with digital caliper (Digimess™). The duplicated dental models were laser scanned and measured by O3d software (Widialabs™). From the models used for the second study 21 pairs of gypsum models were selected for the third study, because they had cephalometric measures that were consulted and tabbed. In the first study happened, in 25% of the models, bacterial growth of coagulase-negative Staphylococcus; Micrococcus sp.; Bacillus sp. and nonfermenting Gram-negative bacillus and, in 5,7%, fungal growth of Cladophialophora sp.; Trichosporon beigelii; Aspergillus flavus and Aureobasidium pullulans. So, it's important that the dentist avoid crossed contamination and the digital models technology can avoid to store dental... (Complete abstract click electronic access below) / Doutor
15

Alterações tridimensionais dos arcos dentários de pacientes submetidos à cirurgia ortognática

Peixoto, Adriano Porto [UNESP] 01 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-01Bitstream added on 2014-06-13T18:32:08Z : No. of bitstreams: 1 peixoto_ap_me_arafo.pdf: 645437 bytes, checksum: d3539d3af25cbe222527bc3beef84415 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O tratamento ortodôntico-cirúrgico pode levar a mudanças dimensionais dos arcos dentários nos períodos pré e pós-cirúrgico. Existem poucos estudos bem formulados que procuraram avaliar as mudanças pré e pós-cirúrgicas nas dimensões dos arcos dentários e sua correlação com a estabilidade. Tais mudanças, somente podem ser corretamente avaliadas através de ferramentas tridimensionais. Modelos de gesso dos arcos dentário superior e inferior de pacientes submetidos a tratamento ortodôntico-cirúrgico para a correção das más oclusões esqueléticas de Classe II e classe III foram obtidos em três diferentes tempos: (T1) modelos iniciais, (T2) modelos pré-cirúrgicos imediatos (de 1 a 15 dias antes da cirurgia) e (T3) modelos pós-cirúrgicos (mínimo de 6 meses após a remoção do aparelho ortodôntico). Pontos previamente demarcados, foram digitalizados através do digitalizador tridimensional MicroScribe-3DX, cujas coordenadas armazenadas em planilhas do programa Excel possibilitaram avaliar a largura, o comprimento e a profundidade dos arcos dentários. Os resultados demonstraram para a classe II, que durante o preparo ortodôntico, houve aumentos nas distâncias transversais superiores e inferiores medidas na região de pré-molares que se mantiveram no período total de acompanhamento. Apenas a distância inter-caninos superior, apresentou alterações de aumento durante o preparo ortodôntico. Não foram observadas alterações sagitais ou verticais durante os períodos de observação. Diferentemente para a classe III, apenas o arco dentário superior sofreu expansão transversal na região de caninos e pré-molares durante o preparo ortodôntico pré-cirúrgico com tendência à inclinação vestibular dos dentes posteriores. Após a cirurgia, as dimensões transversais não foram afetadas. O arco dentário inferior sofreu poucas influências... / Surgical orthodontics treatment may induce pre-surgical and post-surgical dental arch changes. There are very few well designed investigations to evaluate pre surgical and post surgical dental arch changes and their connection to stability. Dental arch changes can be properly evaluated only by tridimensional tools. Dental casts of upper and lower dental arches from patients who were under orthodontic-surgical treatment to correct classes II and class III skeletal malocclusion were obtained in three phases: (T1) initial models, (T2) immediate pre-surgical models (from 1 to 15 days before surgery) and (T3) post-surgical models (at least 6 months after orthodontic appliance removal). Pre-marked points were digitalized by tridimensional MicroScribe-3DX digitizer. The coordinates kept in Excel tables, enabled to evaluate width, length and depth of the dental arches. The class II malocclusion sample showed upper and lower inter pre-molar and upper intercanines width increase with tendency to buccal inclination during pre surgical orthodontics that remained stable during the entire follow-up. No sagital nor vertical alterations were observed during all evaluated phases. Differently for class III, only upper dental arch suffered transversal expansion on canines and pre-molars regions during orthodontic pre-surgical treatment with tendency to buccal inclination from all of posterior teeth. After surgery, transversal dimensions were not affected. Lower dental arch suffered few changes by orthodontic pre-surgical treatment. When all phases were evaluated, raises on transversal dimensions from second molars and first pre-molars were observed. No sagital nor vertical alterations were observed during observation phases. It was concluded that pre-surgical orthodontics impacts mainly on upper and lower dental arch width between canines... (Complete abstract click electronic access below)
16

Análise dimensional dos biomodelos de senterização seletiva a laser, impressão tridimensional e polyjet, na reprodução da anatomia mandibular

Ibrahim, Danilo January 2006 (has links)
Made available in DSpace on 2011-12-27T14:14:20Z (GMT). No. of bitstreams: 2 000386107-0.pdf: 21877982 bytes, checksum: d162d1f0cbee3f552d59febeff308ca1 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The Rapid Prototyping (RP) techniques have been used to make prototypes or models, with biomedical images. To be applied in Traumatology and Maxillofacial Surgery, the prototypes must reproduce the craniofacial skeleton, with acceptable precision. The current research aims the analysis of the dimensional error and the reproductive capacity of mandibular anatomy of the prototypes of SLS, 3DP™ and PolyJet™ details. The methodological procedures involved the acquisition of helical volume computed tomography from a dry mandible (gold-standard), followed by tomographics images manipulation using a national software – InVesalius – and the production of prototypes using SLS, 3DP™ and PolyJet™ techniques. Using a digital caliper, thirteen linear measures were obtained in the prototypes, twenty times repeated, and compared to the dry mandible. The results showed a dimensional error of 1,79%, 3,14% e 2,14% for SLS, 3DP™ and PolyJet™ models, respectively. The prototypes satisfactorily reproduced the anatomic details. From the methodology applied and the obtained results it follows that the SLS prototype have a greater dimensional precision than the PolyJet ™ and 3DP™ models. However, the PolyJet™ techniques reproduces the mandibulary anatomy with a better fidelity SLS than the SLS and 3DP™ systems. / As técnicas de Prototipagem Rápida (PR) têm sido utilizadas para produzir protótipos ou modelos físicos, a partir de dados de imagens biomédicas. Para aplicação dos biomodelos em Cirurgia e Traumatologia Bucomaxilofoacial (CTBMF), os protótipos devem reproduzir a região craniofacial, com aceitável precisão. A presente pesquisa analisa o erro dimensional e a capacidade reprodutiva da anatomia mandibular dos biomodelos de Sinterização Seletiva a Laser (SLS), Impressão Tridimensional (3DP™) e PolyJet™. Os procedimentos metodológicos envolveram a aquisição de imagens de tomografia computadorizada helicoidal de uma mandíbula seca (padrão-ouro), seguida da manipulação das imagens pelo software InVesalius e confecção dos biomodelos. Empregando-se o paquímetro eletrônico digital, foram efetuadas 13 medidas lineares, repetidas por 20 vezes em cada biomodelo e estas comparadas às correspondentes na mandíbula seca. Os resultados revelaram erro dimensional de 1,79%, 3,14% e 2,14% para os biomodelos de SLS, 3DP™ e PolyJet™, respectivamente. Os biomodelos reproduziram satisfatoriamente os detalhes anatômicos. A partir da metodologia empregada e dos resultados obtidos, concluiu-se que o biomodelo de SLS possui maior precisão dimensional que os biomodelos de PolyJet™ e 3DP™. Entretanto, a técnica de PolyJet™ reproduz com mais fidelidade a anatomia mandibular, seguida dos sistemas de SLS e 3DP™.
17

Avaliação da precisão das técnicas de moldagem para próteses implantossuportadas sobre implantes alinhados e implantes não-alinhados

Muñoz Chávez, Alejandro [UNESP] 28 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-28Bitstream added on 2014-06-13T19:58:14Z : No. of bitstreams: 1 munozchavez_a_me_arafo.pdf: 1098693 bytes, checksum: 17a654ba992a69bd6c38b4699551735e (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Quadrados, Quadrados unidos e Quadrados com prolongamentos em forma de hélice) associadas a duas situações clinicas (análogos alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Duas estruturas metálicas de três elementos sendo três alinhados e três não-alinhados e vinte e uma moldeiras individuais de resina acrílica foram confeccionadas. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (FujiRock -GC Corp), espatulado à vácuo. Foi obtido um total de vinte e um modelos, sendo sete por técnica, mais sete registros do index... / The present in vitro study compared the dimensional accuracy of a master cast (control group) with verification jig (Index) and 3 impression techniques (squared impression copings, squared impression copings splinted with autopolymerizing acrylic resin and squared impression copings with prolongations created from autopolymerizing acrylic resin in the vestibule-lingual direction). Materials and Methods. An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas, two passive implant frameworks and twenty-one identical custom impression trays were made with autopolymerizing acrylic resin... (Complete abstract, click electronic access below)
18

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados /

Munhoz Cháves, Alejandro. January 2009 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Sergio Sualdini Nogueira / Banca: Rafael Leonardo Xediel Consani / Banca: Pedro César Garcia de Oliveira / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que: ...(Resumo completo, cliar acesso eletrônico abaixo) / Abstract: An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material. / Doutor
19

AVALIAÇÃO POR MEIO DE MODELOS VIRTUAIS TRIDIMENSIONAIS DAS DISTÂNCIAS INTERCANINOS E INTERMOLARES INFERIORES EM TRÊS MOMENTOS / Evaluation through three-dimensional virtual models of the alterations of the inferior intercanine and intermolar widths in patients treated orthodontically.

Viek, Roberto 28 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:11Z (GMT). No. of bitstreams: 1 Roberto Viek.pdf: 731404 bytes, checksum: d2b2835010e2893c6d296bcf98c35971 (MD5) Previous issue date: 2008-02-28 / The purpose of this study was to evaluate the stability of the orthodontic treatment in three distinct moments, by measuring the inferior intercanine and intermolar widths using three-dimensional virtual models as tools. Inferior arch cast models of 19 patients in three distinct phases were selected, pretreatment (T1), post treatment (T2) and minimum of 5 years post-contention (T3), adding up to 57 models, which were digitalized through Scanner 3D SCANTEH ST500 (SCAN technology A/S, CITY, Denmark), to obtain three-dimensional virtual models. In these three-dimensional virtual models, the distances between cuspids of the canines, called intercanine width and the distance between cuspids mesio-buccal of the first molars, called intermolar width, were selected and measured with the help of the software Rapidform (Inus Technology Inc). In order to do a statistical analysis, the analysis of variance of repeated measures was performed, and also, multiple comparisons of Bonferroni at significance level of 5% were performed. The intercanine and intermolar widths, on an average, decreased between T1-T2 and kept on decreasing between T2-T3. After 4 weeks, 20% of the sample was measured again to evaluate the fault of the method, where we can find average values similar to the ones found in the first measuring. In this study, by using threedimensional virtual models, it is possible to notice that there is no stability during and after the orthodontic treatment, concerning intercanine and intermolar widths.(AU) / O propósito desse estudo foi de avaliar a estabilidade do tratamento ortodôntico em três momentos distintos, por meio de mensuração das distâncias intercaninos e intermolares inferiores, utilizando, como ferramenta, modelos virtuais tridimensionais. Foram selecionados modelos de gesso da arcada inferior de 19 pacientes em três fases distintas: pré-tratamento (T1), pós-tratamento (T2) e mínimo de 5 anos pós-contenção (T3), totalizando 57 modelos, os quais foram digitalizados por meio do Scanner 3D SCANTEH ST500 (SCAN technology A/S, Dinamarca), para obtenção dos modelos virtuais tridimensionais. Nesses modelos virtuais tridimensionais foram selecionadas e mensuradas as distâncias entre as pontas de cúspide dos caninos, denominada distância intercaninos e pontas de cúspide mesiovestibulares dos primeiros molares, denominada distância intermolares, com o auxílio do programa Rapidform ( Inus Technology Inc,). Para a análise estatística, foi realizada a análise de variância de medidas repetidas, e realizadas comparações múltiplas de Bonferroni ao nível de significância de 5%. As distâncias intercaninos e intermolares, em média, diminuíram entre T1-T2 e continuaram diminuindo entre T2- T3. Após 4 semanas, 20% da amostra foi novamente mensurada para avaliação do erro do método, onde foram encontrados valores médios semelhantes aos encontrados na primeira mensuração. Nesse trabalho, utilizando-se modelos virtuais tridimensionais, nota-se que não há estabilidade durante e após o tratamento ortodôntico, no tocante às distâncias intercaninos e intermolares.
20

Precisão das técnicas de moldagem para próteses implantossuportadas /

Del'Acqua, Marcelo Antonialli. January 2009 (has links)
Resumo: Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group's measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below) / Orientador: Marco Antonio Compagnoni / Coorientador: Francisco de Assis Mollo Junior / Banca: Wellington Cardoso Bonachela / Banca: Ricardo Faria Ribeiro / Banca: Gelson Luis Adabo / Banca: João Neudenir Arioli Filho / Doutor

Page generated in 0.1252 seconds