Dissertação (mestrado)—Universidade de Brasília, Instituto de Biologia, Pós-graduação em Nanociência e Nanobiotecnologia, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-04-27T18:16:20Z
No. of bitstreams: 1
2015_PauloRobertodosSantos.pdf: 3035381 bytes, checksum: b61c480db51b39b4ede83c3ae01411fe (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2016-05-04T14:39:09Z (GMT) No. of bitstreams: 1
2015_PauloRobertodosSantos.pdf: 3035381 bytes, checksum: b61c480db51b39b4ede83c3ae01411fe (MD5) / Made available in DSpace on 2016-05-04T14:39:09Z (GMT). No. of bitstreams: 1
2015_PauloRobertodosSantos.pdf: 3035381 bytes, checksum: b61c480db51b39b4ede83c3ae01411fe (MD5) / Testes com ensaio imunológico tornaram-se uma importante ferramenta para diagnóstico clínico e em desenvolvimento de pesquisa. É cada vez mais crescente a aplicação de nanopartículas magnéticas em ensaios imunológicos afim de separar e quantificar antígenos. Normalmente o diâmetro da nanopartícula em conjunto com a cobertura é de algumas dezenas de nanômetros até alguns micrômetros. Na medicina, essas nanopartículas podem ser usadas tanto “in vivo” (partículas introduzidas no corpo do paciente) como “in vitro” (ensaios imunológicos e outros tipos de manipulação). No caso do uso “in vivo” existe a limitação do tamanho que é de até da ordem de poucas centenas de nanômetros. Nesta dissertação propomos um protótipo para o estudo e desenvolvimento de um sistema de baixo custo para detecção de nanopartículas magnéticas em meio líquido utilizando sensores magnéticos disponíveis no mercado. / Tests with immunoassay become an important tool in clinical diagnostics and in research development. It is ever increasing application of magnetic nanoparticles in immunological assays in order to separate and quantify antigens. Typically the diameter of the nanoparticle together with the cover is a few tens of nanometers to a few micrometers . In medicine, these nanoparticles can be used both " in vivo " ( particles introduced into the patient's body) and "in vitro " ( immunoassays and other manipulation) . In the case of use " in vivo " There is a size limitation which is up to the order of a few hundred nanometers. In this work we propose a prototype for the study and development of a low cost system for detection of magnetic nanoparticles in liquid media using magnetic sensors available on the market.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/20115 |
Date | 01 December 2015 |
Creators | Santos, Paulo Roberto dos |
Contributors | Santos, Judes Gonçalves dos |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB |
Rights | A concessão da licença desta coleção refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições:Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess |
Page generated in 0.0018 seconds