Return to search

Analise fotoelástica em diferentes protocolos de reabilitação utilizando implantes dentais em maxilas edêntulas atróficas / Photoelastic analysis on different protocols rehabilitation using dental implants in atrophic edentulous maxilla

Orientador: José Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T16:30:04Z (GMT). No. of bitstreams: 1
Moraes_PauloHemersonde_M.pdf: 14156681 bytes, checksum: ca90b60d99caa756d6b1104881f6bf54 (MD5)
Previous issue date: 2011 / Resumo: Com o avanço da implantodontia, as maxilas edêntulas atróficas que anteriormente eram indicações de enxertos ósseos para viabilizar a reabilitação com implantes dentais, atualmente é possível contornar a maioria destes quadros clínicos sem a necesidade de enxertos ósseos utilizando técnicas como implantes zigomáticos. No entanto, visando a manutenção destes tratamentos aplicados, torna-se essencial o conhecimento do comportamento biomecânico destas modalidades de tratamentos. Diante do exposto, a presente pesquisa apresenta 3 estudos biomecânicos ¿in vitro¿ descritos nos capítulos a seguir. CAPÍTULO I: O objetivo deste estudo foi analisar as tensões mecânicas ao redor dos implantes e ossos adjacentes por meio de análise fotoelástica simulando três combinações de reabilitações com implantes zigomáticos. Cargas oclusais na região do primeiro molar foram simuladas, e a distribuição de tensões sobres os implantes e ossos adjacentes foram examinados. A distribuição das cargas foi observada predominantemente nas regiões de corpo e processo frontal do osso zigomático para ambos os modelos analisados. A distribuição de tensões analisadas pela análise fotoelástica concentrou-se no corpo e processo frontal do osso zigomático. No modelo 1 (2 implantes zigomáticos + 2 implantes convencionais), maiores concentrações foram encontradas ao redor dos implantes e osso adjacente. Diante dos testes realizados, a reabilitação com 2 implantes zigomáticos com 4 implantes convencionais (Modelo 2) são mais favoráveis mecanicamente. CAPÍTULO II: O objetivo deste estudo foi analisar a distribuição de tensões em estruturas craniofaciais e regiões adjacentes aos implantes de dois tipos de reabilitação com conceito All-on- Four utilizando implantes zigomáticos. Os testes fotoelásticos mostraram concentração de carga no corpo e processo frontal do osso zigomático. A partir das análises obtidas, ambos os modelos apresentam satisfatório comportamento mecânico / Abstract: With the advancement of implantology, atrophic edentulous jaws that previously were indications of bone grafts to enable rehabilitation with dental implants, actually is possible to circumvent most of these clinical situations without the need for bone grafts using techniques such as the zygomatic implants. However, for the maintenance of these treatments, becomes essential knowledge of the biomechanical behavior of these treatment modalities. Given the above, this research presents three biomechanical studies in vitro described in the following chapters. CHAPTER I: The aim of this study was to analyze the mechanical stresses around the implants and surrounding bone by photoelastic analysis simulating combinations of three rehabilitations with zygomatic implants. Occlusal loads in first molar region were simulated, and the stress distribution on the implants and surrounding bone were examined. The load distribution was observed predominantly in the body and frontal process of zygomatic bone for both models analyzed. The stress distribution analyzed by photoelastic analysis concentrated on the body and frontal process of zygomatic bone. Model 1 (2 + 2 zygomatic implants conventional implants), higher concentrations were found around the implants and surrounding bone. Before the tests, rehabilitation with two zygomatic implants with conventional implants 4 (Model 2) are better mechanically. CHAPTER II: The aim of this study was to analyze the stress distribution in craniofacial structures and regions adjacent to implants of two types of rehabilitation with All-on-Four concept using zygomatic implants. The photoelastic tests showed load concentration in the body and frontal process of zygomatic bone. From the analysis obtained, both models have satisfactory mechanical properties. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289447
Date02 October 2011
CreatorsMoraes, Paulo Hemerson de, 1982-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Albergaria-Barbosa, José Ricardo de, 1956-, Caria, Paulo Henrique Ferreira, Sawazaki, Renato
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format27 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds