Return to search

Avaliação da corrosão em juntas soldadas de fios dissimilares Ni-Ti/Ti-Mo obtidas pelo processo de TIG. / Evaluation of corrosion in weld joints of dissimilar Ni-Ti / Ti-Mo wires obtained by the TIG process.

Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-03-16T19:08:32Z
No. of bitstreams: 1
JOSIANE DANTAS COSTA - DISSERTAÇÃO PPGEQ 2015..pdf: 2694660 bytes, checksum: b1f464f2e8b29d82a5339c5bd52471b3 (MD5) / Made available in DSpace on 2018-03-16T19:08:32Z (GMT). No. of bitstreams: 1
JOSIANE DANTAS COSTA - DISSERTAÇÃO PPGEQ 2015..pdf: 2694660 bytes, checksum: b1f464f2e8b29d82a5339c5bd52471b3 (MD5)
Previous issue date: 2015-09-29 / A liga de Ni-Ti, conhecida por Nitinol, é constituída dos elementos níquel e titânio e vem
sendo bastante aplicada nas mais diversas áreas: aeroespacial, automotiva, construção civil, dispositivos médicos e ortodônticos. Esse potencial de aplicação decorre das propriedades particulares de efeito de memória de forma e superelasticidade, associada a uma boa resistência à corrosão e excelente biocompatibilidade. Com intuito de aumentar as aplicações desse material em dispositivos médicos, o desenvolvimento de tecnologias de união torna-se necessário para possibilitar a fabricação das mais diferentes formas geométricas e combinações entre materiais similares e dissimilares. Nesse contexto, é fundamental que se realize estudos sobre a resistência a corrosão da região em que foi feita a união (junta), principalmente quando utilizados processos de soldagem, já que podem deixar falhas induzindo a uma maior suscetibilidade a corrosão. Diante disto, neste trabalho foi realizada a união de fios ortodônticos de Ni-Ti com fios ortodônticos de Ti-Mo através do processo de soldagem TIG (“Tungsten Inert Gas”) autógeno. Como se trata de biomateriais, este estudo teve como objetivo geral avaliar a resistência à corrosão dos fios comerciais íntegros e da junta soldada Ni-Ti/Ti-Mo em solução salina tamponada SBF (“Saline Buffered Phosphate”) que simula o sangue humano, para verificar se a soldagem afetaria a resistência a corrosão das
juntas. Os resultados obtidos revelaram que o processo da soldagem TIG utilizado neste
trabalho gerou juntas soldadas de excelente qualidade, apresentando uma resistência à
corrosão superior à dos fios íntegros. O planejamento experimental utilizado para verificar a influência da temperatura e do tempo do tratamento térmico nos resultados de corrosão, gerou um experimento ótimo com temperatura de 350°C e um tempo de 40 minutos. Este resultado foi confirmado através dos ensaios de espectroscopia de impedância eletroquímica. / The Ni-Ti alloy, known as Nitinol, is made of nickel and titanium elements and has been
widely applied in several areas: aerospace, automotive, construction, medical and orthodontic appliances. Nitinol's application potential is due to its particular superelasticity properties and shape memory effect associated with a good corrosion resistance and excellent biocompatibility. In order to increase the applications of this material in medical devices, the development of joining technologies is necessary to enable manufacture of the most different geometric shapes and combinations of similar and dissimilar materials. In this context, it is essential to conduct studies on the corrosion resistance of the region where the union (joint) was done, especially when welding processes are used, as they can leave gaps leading to greater susceptibility to corrosion. With this in mind, this work carried out the union of Ni-Ti orthodontic wire with Ti-Mo orthodontic wire through the autogenous TIG (Tungsten Inert Gas) welding process. As biomaterials are involved, this study aimed to evaluate the corrosion resistance of the upright commercial wire and welded joint Ni-Ti/Ti-Mo in buffered saline solution SBP (Saline Buffered Phosphate) which simulates human blood, to check if the welding would affect the corrosion resistance of the joint. The results revealed that the TIG welding process used in this work generated welds of excellent quality, having a corrosion resistance higher than that of intact wires. The experimental design used to determine the influence of temperature and time of heat treatment on the results of corrosion generated a great experiment with temperature of 350 ° C and a time of 40 minutes. This result was confirmed by means of electrochemical impedance spectroscopy test.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/295
Date16 March 2018
CreatorsCOSTA, Josiane Dantas.
ContributorsALVES, José Jailson Nicácio., PRASAD, Shiva., PEREIRA NETO, Antônio Tavernard., SANTANA, Renato Alexandre Costa de.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICA, UFCG, Brasil, Centro de Ciências e Tecnologia - CCT
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0027 seconds