• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da corrosão em juntas soldadas de fios dissimilares Ni-Ti/Ti-Mo obtidas pelo processo de TIG. / Evaluation of corrosion in weld joints of dissimilar Ni-Ti / Ti-Mo wires obtained by the TIG process.

COSTA, Josiane Dantas. 16 March 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-03-16T19:08:32Z No. of bitstreams: 1 JOSIANE DANTAS COSTA - DISSERTAÇÃO PPGEQ 2015..pdf: 2694660 bytes, checksum: b1f464f2e8b29d82a5339c5bd52471b3 (MD5) / Made available in DSpace on 2018-03-16T19:08:32Z (GMT). No. of bitstreams: 1 JOSIANE DANTAS COSTA - DISSERTAÇÃO PPGEQ 2015..pdf: 2694660 bytes, checksum: b1f464f2e8b29d82a5339c5bd52471b3 (MD5) Previous issue date: 2015-09-29 / A liga de Ni-Ti, conhecida por Nitinol, é constituída dos elementos níquel e titânio e vem sendo bastante aplicada nas mais diversas áreas: aeroespacial, automotiva, construção civil, dispositivos médicos e ortodônticos. Esse potencial de aplicação decorre das propriedades particulares de efeito de memória de forma e superelasticidade, associada a uma boa resistência à corrosão e excelente biocompatibilidade. Com intuito de aumentar as aplicações desse material em dispositivos médicos, o desenvolvimento de tecnologias de união torna-se necessário para possibilitar a fabricação das mais diferentes formas geométricas e combinações entre materiais similares e dissimilares. Nesse contexto, é fundamental que se realize estudos sobre a resistência a corrosão da região em que foi feita a união (junta), principalmente quando utilizados processos de soldagem, já que podem deixar falhas induzindo a uma maior suscetibilidade a corrosão. Diante disto, neste trabalho foi realizada a união de fios ortodônticos de Ni-Ti com fios ortodônticos de Ti-Mo através do processo de soldagem TIG (“Tungsten Inert Gas”) autógeno. Como se trata de biomateriais, este estudo teve como objetivo geral avaliar a resistência à corrosão dos fios comerciais íntegros e da junta soldada Ni-Ti/Ti-Mo em solução salina tamponada SBF (“Saline Buffered Phosphate”) que simula o sangue humano, para verificar se a soldagem afetaria a resistência a corrosão das juntas. Os resultados obtidos revelaram que o processo da soldagem TIG utilizado neste trabalho gerou juntas soldadas de excelente qualidade, apresentando uma resistência à corrosão superior à dos fios íntegros. O planejamento experimental utilizado para verificar a influência da temperatura e do tempo do tratamento térmico nos resultados de corrosão, gerou um experimento ótimo com temperatura de 350°C e um tempo de 40 minutos. Este resultado foi confirmado através dos ensaios de espectroscopia de impedância eletroquímica. / The Ni-Ti alloy, known as Nitinol, is made of nickel and titanium elements and has been widely applied in several areas: aerospace, automotive, construction, medical and orthodontic appliances. Nitinol's application potential is due to its particular superelasticity properties and shape memory effect associated with a good corrosion resistance and excellent biocompatibility. In order to increase the applications of this material in medical devices, the development of joining technologies is necessary to enable manufacture of the most different geometric shapes and combinations of similar and dissimilar materials. In this context, it is essential to conduct studies on the corrosion resistance of the region where the union (joint) was done, especially when welding processes are used, as they can leave gaps leading to greater susceptibility to corrosion. With this in mind, this work carried out the union of Ni-Ti orthodontic wire with Ti-Mo orthodontic wire through the autogenous TIG (Tungsten Inert Gas) welding process. As biomaterials are involved, this study aimed to evaluate the corrosion resistance of the upright commercial wire and welded joint Ni-Ti/Ti-Mo in buffered saline solution SBP (Saline Buffered Phosphate) which simulates human blood, to check if the welding would affect the corrosion resistance of the joint. The results revealed that the TIG welding process used in this work generated welds of excellent quality, having a corrosion resistance higher than that of intact wires. The experimental design used to determine the influence of temperature and time of heat treatment on the results of corrosion generated a great experiment with temperature of 350 ° C and a time of 40 minutes. This result was confirmed by means of electrochemical impedance spectroscopy test.
2

Influência da velocidade de resfriamento nas temperaturas de transformação e na tendência de amorfização em fitas Ti-Cu-Ni. / Influence of cooling rate in the transformation temperatures and the glass forming ability in Ti-Cu-Ni ribbons.

RAMOS, Alana Pereira. 04 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-04T20:26:12Z No. of bitstreams: 1 ALANA PEREIRA RAMOS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 2592489 bytes, checksum: 5e82ab454a76e1050981da9019ce8fec (MD5) / Made available in DSpace on 2018-04-04T20:26:12Z (GMT). No. of bitstreams: 1 ALANA PEREIRA RAMOS - DISSERTAÇÃO PPG-CEMat 2014..pdf: 2592489 bytes, checksum: 5e82ab454a76e1050981da9019ce8fec (MD5) Previous issue date: 2017-08-07 / As ligas ternárias de Ti-Cu-Ni com memória de forma são conhecidas por apresentarem transformação de fase característica e propriedades semelhantes às ligas binárias Ti–Ni. Estudos realizados com ligas ricas em cobre mostraram que a adição de cobre nas ligas de Ti-Ni reduz a histerese de resposta do efeito de memória de forma e aumenta a TFA (tendência de formação de fase amorfa) ainda pouco estudada com altas porcentagens de cobre. Diante disso, este trabalho teve como objetivo avaliar a influência da velocidade de resfriamento nas temperaturas de transformação e na tendência de amorfização em fitas de Ti-CuNi resfriadas rapidamente. Para tanto, foram produzidas duas fitas Ti01 (Ti 43,5 Cu 37,8 Ni 18,7) e Ti02 (Ti 58,4 Cu 25,6 Ni 16,0) pelo processo melt spinning, variando-se a velocidade linear da roda em 21 m/s e 63 m/s. As amostras foram caracterizadas utilizando-se técnicas DSC, DR-X, RET e MO. Após essa caracterização pode-se afirmar que a técnica de melt spinning permite a produção de fitas muito finas, da ordem de micrômetros, em apenas uma etapa de processamento, assim como também foi possível a produção de fitas amorfas, do sistema Ti-Cu-Ni, sem nenhuma fase cristalina como observado na fita Ti01 e Ti 02 obtidas com velocidade linear de 63m/s. O tratamento térmico foi suficiente para remover todos os defeitos produzidos pelo processo de solidificação rápida e produzir um rápido crescimento de grão, favorecendo o aumento das temperaturas de transformação martensíticas e austeníticas. / Ternary alloys with shape memory Ti-Cu-Ni are known to submit a characteristic phase transformation and properties similar to the and Ti-Ni binary alloy . Studies with rich-copper alloys showed that the addition of copper in alloys Ti-Ni reduces the hysteresis response of the shape memory effect and increases the TFA (tendency to form amorphous phase) still little studied with high percentages of copper. Thus, this study aimed to evaluate the influence of cooling rate on the transformation temperatures and on the tendency of Cu-Ni-Ti ribbons rapidly solidified. Therefore, two ribbons TI01 (Ti 43.5 Cu 37.8 Ni 18.7) and Ti02 (Ti 58.4 Cu 25.6 Ni 16.0) were produced by melt spinning process, varying the wheel linear velocity 21 m/s and 63 m/s. The samples were characterized using DSC, X-DR, RET and MO and techniques. Melt spinning technique allows the production of very thin ribbons of the order of microns, in one processing step, as it was also possible to produce amorphous ribbons, the system Ti-Cu-Ni, without crystalline phase as observed in TI01 and 02 Ti02 with linear velocity of 63m/s. The heat treatment was sufficient to remove all defects produced by rapid solidification process and produce a rapid grain growth, favoring the increase of temperatures of martensitic and austenitic transformation.

Page generated in 0.1186 seconds