Return to search

Propriedades mecanicas e de resistencia a corrosão de ligas Ti-35Nb a serem aplicadas como biomaterial / Mechanical properties and corrosion resistance of the Ti-35Nb alloys applied as biomaterial

Orientadores: Rubens Caram Junior, Itamar Ferreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-11T18:56:13Z (GMT). No. of bitstreams: 1
Cremasco_Alessandra_M.pdf: 37516014 bytes, checksum: edfb74db9675b3aa63db74dea7998021 (MD5)
Previous issue date: 2008 / Resumo: As ligas de titânio correspondem à classe mais versátil de materiais metálicos empregados em implantes ortopédicos. Dentre tais ligas, encontram-se as do tipo ß, que devem se tornar em breve o padrão nesse tipo de aplicação.O presente trabalho tem como objetivo a preparação e a caracterização de amostras da liga de titânio tipo ß ?de composição Ti-35Nb (% em peso) processadas sob duas condições distintas de resfriamento, rápida e lentamente, a partir do campo de temperaturas ß. Foram realizados estudos ligados à estabilidade microestrutural, ao efeito de tratamentos térmicos na microestrutura, ao comportamento mecânico, à resistência à corrosão e finalmente, à resistência à fadiga, em meio neutro e em meio agressivo. Observou-se que sob resfriamento lento, a microestrutura da liga Ti-35Nb é formada pela fase ß ?com precipitados da ß e de martensita a". Tratamentos térmicos de envelhecimento resultaram na transformação da martensita a" em fase ß, seguida da nucleação das fases ? ?e a. Ensaios mecânicos mostraram que o módulo de elasticidade e a dureza de ligas resfriadas lentamente foram significativamente superiores aos valores obtidos com as amostras resfriadas rapidamente. Da mesma forma, observou-se que as amostras resfriadas lentamente apresentam maior limite de resistência à tração e inferior nível de ductilidade. Ensaios de resistência à corrosão mostraram comportamento semelhante para ambas as amostras resfriadas rápida e lentamente, o que mostra que a taxa de resfriamento e conseqüentemente, as fases formadas não alteram significativamente a resistência à corrosão. Os ensaios de fadiga mostraram que as amostras processadas sob as duas condições de resfriamento apresentaram limite de resistência à fadiga inferior ao da liga Ti-6Al-4V. A liga resfriada rapidamente apresentou valor maior que a mesma liga resfriada em forno. Os valores de resistência à fadiga em solução de 0,9% NaCl de amostras resfriadas rápida e lentamente exibiram leve tendência de redução em relação ao meio neutro. / Abstract: Titanium alloys form the most versatile class of metallic materials used as biomaterials. Among them, one finds the ß ?type alloy, which must soon become the standard metallic materials for orthopedic applications. The aim of this work is to prepare and characterize a type ß ?titanium alloy containing 35 wt.% Nb. Samples of such alloy were rapidly and slowly cooled from the ß ?field temperatures. This work includes studies of microstructure stability, effects of heat treatment on the microstructure, evaluation of corrosion resistance and finally, analysis of fatigue resistance in non-aggressive and aggressive media. The results obtained allowed one to observe that microstructure of slowly cooled samples is formed by precipitates of ß ?and a phases in a ? ?matrix. Under rapid cooling, the microstructure consists of ß ?phase and a" martensite. Aging heat treatments resulted in the transformation of a" martensite into ß ?phase, followed by ? ?phase precipitation and hence, a ?phase nucleation. Mechanical testing showed that the elastic modulus and Vickers hardness of slowly cooled samples were significantly higher than that obtained in the case of the rapidly cooled samples. On the other hand, it was observed that slowly cooled samples showed higher tensile strength and lower ductility. Corrosion resistance testing led to the conclusion that both rapidly and slowly cooled samples have similar corrosion behavior, which allows one to conclude that cooling rate and consequently, the phases in the microstructure do not have a relevant influence on the corrosion resistance. Fatigue testing showed that both types of sample (rapidly and slowly cooled samples) have fatigue resistance lower than that of the Ti-6Al- 4V alloy. The rapidly cooled sample showed fatigue resistance higher than that of slowly cooled samples. The fatigue resistance measured in a NaCl (0,9% vol.) solution of both types of samples showed a slight tendency of reduction when compared to the same samples tested in nonaggressive medium. / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/263199
Date25 February 2008
CreatorsCremasco, Alessandra, 1983-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Ferreira, Itamar, 1952-, Caram Junior, Rubens, 1958-, Junior, Rubens Caram, Fogagnolo, João Batista, Freire, Celia Marina de Alvarenga
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format107p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0027 seconds